Advantage • High read accuracy 0.5% • Mini handheld • Low power consumption • Lower zero drift down to 5mV Related Products Y-FCT,NRC,MRC | Applications Measuring devices, lab instrumentation • Power monitoring & analysis • Harmonics and transients monitoring • Welding machine control • High current measurement |
Model | S2.1 |
Rated Input | 300A/3000A(switchable) |
Rated output | 3V AC rms |
Maximum Output(overload) | 5V pp |
Input Connection | Fixed with Rogowski coil cable(NRC-150) |
Output terminal | 0.5 meter BNC male terminal |
Output Ripple factor | 1% |
Response time | ≤1us |
Power consumption | 0.2VA |
Bandwidth | 10Hz to 10kHz |
Power supply | 2pcs AA 1.5V battery(not included) |
3.5*1.3mm DC 5V/2A adaptor(included) | |
Read Accuracy | 0.5% typical at 1%(≥10A) to 200% of rated Current @25ºC |
Phase error | ≤0.5° |
Linearity | ±0.2% of reading(1% to 200% of range) |
Minimum Current measurement | 1A (Ripple 100mA) |
Output on 0A (zero drift) | ≤1mV (rated outut ≥2.5V:zero drift<5mV) |
Temperature drift | 200ppm/ºC |
Weight | 300g |
Dimension | 144*43.5*34mm |
Operating temperature | -20ºC to 70ºC |
Storage temperature | -30ºC to 90ºC |
Relative humidity: | 80% max.without condensation |
Protection degree: | IP20 |
Housing material: | PPE+10%PSGF |
Other requirements, please contact us to OEM. |
Coil Model | Coil diameter (mm) | Output ratio and tolerance | Signal cable length |
Code:Y-FCT | Code:200(Typical rated 500A) Code:350(Typical rated 1500A) Code:510(Typical rated 3kA) Code:800(Typical rated 10kA) Y-FCT code is length. | Code:110 110mV/kA@50Hz±5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | Code:-2m Code:-5m Code:-10m Code:-20m |
Code:NRC | Code:100(Typical rated 1kA) Code:150(Typical rated 3kA) Code:200(Typical rated 6kA) | ||
Code:MRC | Code:16(Typical rated 100A) Code:24(Typical rated 300A) Code:36(Typical rated 600A) | Code:60 60mV/kA@50Hz±5% Code:50 50mV/kA@50Hz±0.5% | |
Code:SRC | Code:50 Code:100 Code:150 | Code:360 360mV/kA@50Hz±5% Code:333 333mV/kA@50Hz±0.5% Code:100 100mV/kA@50Hz±0.5% Code:85 85mV/kA@50Hz±0.5% Code:50 50mV/kA@50Hz±0.5% | |
Other requirement could be OEM |
Integrator | Output form | Output value | Rated current | Power supply |
Code:D1 (DIN-RAIL integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -5(5V) | Code: -600A Code: -1kA Code: -3kA Code: -6kA | Code: -12(12V DC) Code: -24(24V DC) |
Code: .3(4-20mA output) | N/A | |||
Code:S9 (mini integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -1(1V) Code: -3(3V) | Code: -12(6-12V DC) Code: -24(24V DC) | |
Code:S1 (high accuracy integrator) | Code: .1(AC voltage output) Code: .2(DC voltage output) | Code: -333(333mV) Code: -5(5V) Code: -10(10V) | Code: -12(4-12V DC) Code: -24(24V DC) | |
Code: .3(4-20mA output) | N/A | |||
Code:ATP-01 (1A output three phase integrator) | N/A(0-1A) | N/A | Code: -12(12V DC) Code: -24(24V DC) | |
Code:A01 (1A output integrator) | N/A(0-1A) | N/A | N/A(85-265V AC DC) | |
Code:A05 (5A output integrator) | N/A(0-5A) | N/A | N/A(85-265V AC DC) | |
Code:HF (high frequency integrator) | N/A(0-10VAC peak) | N/A | Code: -1kA(1kA/1V) Code: -10kA(10kA/1V) | N/A(4-12V DC) |
Other requirement could be OEM |