China Prefab Factory Building Steel Structure Poultry Warehouse Construction Materials, Find details about China Isolated Hospital, Thunder God Mountain Isolated Hospital from Prefab Factory Building Steel Structure Poultry Warehouse Construction Materials
No. | Sort | Name | Specification: |
1 | Specification | length | No limited |
2 | Width | Less than 11m | |
3 | Wall height | 2600mm/2800mm | |
4 | Clear height | 2600mm/2800mm | |
5 | Roof slope | 15° | |
6 | Standard accessory | Wall board | 75mm thickness double color-steel sandwich panel with polystyrene foam inside. Heat Insulated coefficient is 0.041w/m.k. Heat transfer coefficient is 0.546w/ m².k. |
7 | False ceiling | 75mm thickness double color-steel sandwich panel with polystyrene foam inside. Heat Insulated coefficient is 0.041w/m.k. Heat transfer coefficient is 0.546w/ m².k. | |
8 | Roof board | color steel corrugated sheet, 0.5mm thickness | |
9 | Outside door | Security door, single door with dimensions of 900*2100mm, furnished with a handle lock with 3keys. Doorframe is made of 1.2mm steel, and door is made of 0.7 mm steel, 90mm thick rock wool insulation foam. | |
10 | Inside door | SIP, single door with dimensions of 750*2000mm, furnished with a cylinder lock with 3keys. Doorframe is made of aluminum, 50mm thick EPS insulation foam. | |
11 | Window(W-1) | PVC, white color, with dimensions of 1200*1200mm, glazed with glass in a thickness of 5mm, two bay fixed, and two bay sliding, supplied with fly screen. | |
12 | Window(W-2) | PVC, white color, with dimensions 500*500mm, glazed with glass in a thickness of 5mm, casement opening, supplied with fly screen. | |
13 | Channel | Galvanized Steel Plain Sheet press moulding Material: Q235. Painted | |
14 | Post | Square steel tube Material: Q235. Painted | |
15 | Purline | Square steel tube Material: Q235. Painted | |
16 | Roof truss | Square steel tube Material: Q235. Painted | |
17 | Decoration and connection | color steel sheet, 0.35mm thickness | |
18 | Option | Decorative floor | PVC, laminated or ceramic tile |
19 | Drainage system | Provided plan, design and construction | |
20 | Electric system | Provided plan, design and construction | |
21 | Technical parameter | Bearing load | 30kg/m2 |
22 | Wind pressure: | 0.45KN/M2 | |
23 | Fire proof | B2 grade | |
24 | Resistant temperature | -20 ºC to 50º |
1 | Location (where will be built?) | _____country, area |
2 | Size: length*width*height | _____mm*_____mm*_____mm |
3 | wind load (max. wind speed) | _____kn/m2, _____km/h, _____m/s |
4 | snow load (max. snow height) | _____kn/m2, _____mm |
5 | anti-earthquake | _____level |
6 | brickwall needed or not | If yes, 1.2m high or 1.5m high |
7 | thermal insulation | If yes, EPS, fiberglass wool, rockwool, PU sandwich panels will be suggested; . if not, the metal steel sheets will be ok. The cost of the latter will be much lower than that of the former |
8 | door quantity & size | _____units, _____(width)mm*_____(height)mm |
9 | window quanity & size | _____units, _____(width)mm*_____(height)mm |
10 | crane needed or not | If yes, _____units, max. lifting weight____tons; max. lifting height _____m |