CE Certificate Home Use Easy Operate Sinewave Inverter From Must Power

China CE Certificate Home Use Easy Operate Sinewave Inverter From Must Power, Find details about China Sinewave Inverter, Sine Wave Inverter from CE Certificate Home Use Easy Operate Sinewave Inverter From Must Power

Model NO.
EP3000
Colour
Black, White
Power
1kw-6kw
DC
12V/24V/48V
Input voltage
155-265VAC for 230VAC, 90-120VAC for 120VAC
Input Frequency
40-80Hz
Charge Current
70A Max
Charge Currante Adjustable
Yes
Remote Control
Option
RS232
Option
Phase
Single
Power Source
Electric Power
Trademark
MUST
Transport Package
Carton and Wooden Box
Specification
CE, ISO,
Origin
Shenzhen, China
HS Code
8504409990
Model NO.
EP3000
Colour
Black, White
Power
1kw-6kw
DC
12V/24V/48V
Input voltage
155-265VAC for 230VAC, 90-120VAC for 120VAC
Input Frequency
40-80Hz
Charge Current
70A Max
Charge Currante Adjustable
Yes
Remote Control
Option
RS232
Option
Phase
Single
Power Source
Electric Power
Trademark
MUST
Transport Package
Carton and Wooden Box
Specification
CE, ISO,
Origin
Shenzhen, China
HS Code
8504409990
CE Certificate Home Use Easy Operate Sinewave Inverter

Pure sine wave inverter solar inverter
Durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads;
Built-in starting control circuits for two- and three-wire generator starting systems;
Simplified controls with a snap-on cover that protects settings from being accidentally changed;
Better thermal performance allows full output power to 50° C (122° F) without de-rating;
High surge capacity starts more difficult loads and handles overload conditions reliably;
Durable powder coated, corrosion resistant steel chassis.
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging, plus incorporates a robust ON/OFF switch and status indicators;
70-AMP automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance;
New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery charging algorithm, reduces electricity draw and generator run-time.
MODEL 
(EP3000)
HV Model
1012E1024E2012E2024E3024E4048E5048E6048E
Line Mode Specifications:
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac(120VAC selectable)
Low Line Disconnect184Vac±4%
Low Line Re-connect194Vac ±4%
High Line Disconnect265Vac±4%
High Line Re-connect255Vac±4%
Max AC Input Voltage270Vrms
Nominal Input Frequency50Hz/ 60Hz  (Auto detection)
Low Line Frequency Re-connect58+0.3Hz for 60Hz;48+0.3Hz for 50Hz;
Low Line Frequency Disconnect57+0.3Hz for 60Hz;47+0.3Hz for 50Hz;
High Line Frequency Re-connect64+0.3Hz for 60Hz;54+0.3Hz for 50Hz;
High Line Frequency Disconnect
65+0.3Hz for 60Hz;55+0.3Hz for 50Hz;
Output Voltage WaveformAs same as Input Waveform
Over-Load Protection(SMPSload)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Efficiency (Line Mode)>95%
Transfer Switch Rating30A
Transfer Time (Ac to Dc)10ms (typical)
Transfer Time (Dc to Ac)10ms (typical)
Pass through without BatteryYes
Max Bypass Overload Current30A
Invert Mode Specifications:
Output Voltage WaveformSine wave
Rated Output Power (VA)100020003000400050006000
Rated Output Power (W)100020003000400050006000
Power Factor0~1.0
Nominal Output Voltage (V)230Vac
Nominal Output Frequency (Hz)50Hz ± 0.3Hz
Auto tracking Main Frequency(Hz)Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz
Output Voltage Regulation±10% rms
Nominal Efficiency>80%

Over-Load Protection
(SMPS load)
(110% 150% ±10%:  Fault (shutdown output) after 20s;
Surge rating (10s)3000VA6000VA9000VA12000VA15000 VA18000VA
Capable of starting electric motor1 HP1 HP2 HP3 HP
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Inverter overload Breaker Size30A30A30A35A50A
Nominal DC Input Voltage12V24V12V24V24V48V48V
Min DC start voltage10V/20V/40V
Low Battery Alarm10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery
Low DC input Shut-down10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery
High DC input Alarm & Fault16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery
High DC input Recovery15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery
Power saverLoad ≤25W (Enabled on "P/S auto" setting of Remote control)
Charge Mode Specifications:
Nominal Input Voltage230Vac
Input Voltage Range196~243Vac
Nominal Output VoltageAccording to the battery type
Nominal Charge Current35A35A65A35A45A35A40A50A
Charge Current Regulation± 5Adc
Battery initial voltage0 -15.7 Vdc (can operate with 0V battery)
Charger Short Circuit ProtectionCircuit breaker
Over Charge ProtectionBat. V ≥15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60s
General Specifications
Safety CertificationCE(EN62040-1)
EMC ClassificationEN62040-2,C2 
Operating Temperature Range0°C to 40°C
Storage temperature15°C below zero to 60°C
Operation humidity5% to 95%
Audible Noise60dB max
CoolingForced air, variable speed fan
Size1012E/1024E2012/2024E/2048E:381mm*217mm*179mm