Plate Tube RO Membrane for Landfill Leachate Treatment

China Plate Tube RO Membrane for Landfill Leachate Treatment, Find details about China Rcdt Membrane, Plate Tube RO Membrane from Plate Tube RO Membrane for Landfill Leachate Treatment

Cross Replacement
Rochem, Rotreat, Pall
Vessel Material
FRP
Trademark
RisingSun
Transport Package
Wooden Box
Origin
China
HS Code
84212990
Cross Replacement
Rochem, Rotreat, Pall
Vessel Material
FRP
Trademark
RisingSun
Transport Package
Wooden Box
Origin
China
HS Code
84212990
RisingSun Membrane's Disc. Tube membrane module includes RO and NF by using different kinds of membrane sheet. The membrane module structure is completed distinct from the traditional spiral wound membrane. With open flow channels, feed flows through the entrance into the pressure vessel and reach the disc in a short distance. Then the feed flows 180 degrees from one side of the membrane reverse flow into the other side of the membrane, into the next disc again and finally runoff from outlet.

Plate Tube RO Membrane for Landfill Leachate Treatment
This special design makes feed collide with the disc bulge through the membrane surface forming turbulence which increases flow rate and self-cleaning function and long service life of the membrane.


Features:
  • High strength design, up to 160bar operation pressure
  • Simple pre-filtration
  • Open channel configuration enables low flow resistance and low concentration polarization, Minimize membrane scaling and fouling
  • Easy to maintain
  • High rejection and high recovery rates with low energy costs (up to 99.6%)
  • Long membrane life
  • Lower membrane replacement costs
  • High quality product water

Application fields:
  • Treatment & re-use of landfill leachate 
  • High concentration of industrial waste water
  • Effluent & waste water treatment from API, formulation plant & combined effluent from pharmaceuticals industry
  • Effluent treatment from textile industry and dyeing unit
  • Picking & oily waste treatment in steel industry
  • Metal recovery waste recycling
  • Traditional spiral RO / NF concentrate treatment 
  • High COD/BOD waste water treatment (max. COD 20,000ppm)

A typical process diagram:

Plate Tube RO Membrane for Landfill Leachate Treatment




90bar High pressure membrane module specification:
 
ItemsHigh pressure (90bar)
   ModelSP-DTRO5-8042
   Membrane sheet Composite Polyamide (RO5)
   Membrane cushion qty. (pc)209
   Stable rejection**99.5%
   Min.  Rejection (%)99.0%
   Membrane effective area (m2)>9.4
   Feed flux** (l/h)500-1200
   Permeate flux range (l/h)400
   Hydraulic disc materialABS
   Vessel materialFRP
   Operation pressure (bar)90
   Max. TMP (bar)9
   Max. operation temperature (ºC)40
   Chlorine tolerance (ppm)<0.1
   Recommended operation pH3-11
   Chemical cleaning  pH@40ºC2-12
** RO5 test condition: 32,000mg/l NaCl solution at 55bar applied pressure, 25ºC; Permeate flux and stable rejection may vary based on inlet water condition. There may have about ±20% change for individual module permeate flux.

Plate Tube RO Membrane for Landfill Leachate Treatment

 
Operation Pressure (bar)90 bar
     Total module length A (mm) 1400
       Vessel length B (mm)1150
      Module diameter C (mm)220
      Vessel to top of frame D (mm)98
      Inlet to flange center distance E (mm)76
      Outlet to flange center distance F (mm)56
      Inlet & outlet connections diameter (mm)12
      Permeate connection (mm)1 x  G3/8"-90° elbow for 9mm  hose


DTRO / DTNF membrane module structure

Plate Tube RO Membrane for Landfill Leachate Treatment

 
ItemNameItemNameItemNameItemName
1Tie rod7End flange13O-ring 14-219Reinforced top flange
2Thick nut 8Screwing tie rod14O-ring 52-420Membrane vessel
3Top flange9Tie rod gasket15O-ring 48-221Reinforced rod
4Distance fitting10Thin nut16Membrane cushion22Reinforced end flange
5Hydraulic disc11Inlet/Outlet connection17O-ring 39-323Reinforced nut
6Lip seal12Permeate connector18Screwing tie rod  


Plate Tube RO Membrane for Landfill Leachate Treatment

Plate Tube RO Membrane for Landfill Leachate Treatment


Why us?

1. Cost is competitive and fast lead time.
2. Cross reference: Rochem DT module and PF module
3. Cross reference: Rotreat RCDT module