Split Core CT with 20A

China Split Core CT with 20A, Find details about China Split Core CT, CT from Split Core CT with 20A

Model NO.
H-CT005-10D
Usage
Distribution Transformer
Frequency Characteristics
Low Frequency
Shape of Core
Ring
Brand
E-Power
Model
H-CT005-10d
Diameter
10mm
Current Ratio
20A/10mA
Rate Primary Current
20A
Max Primary Current
24A
Secondary Turns
2000
Wire Lead
AWG#22
DC Resistance
460ohms +/-20% at 20
Frequency
50/60Hz
Manufacturer
Jiaxing Haihan Electron Co.,Ltd
Trademark
E-Power
Transport Package
Standary Export Carton.
Specification
50*40*30cm
Origin
China
HS Code
8504500000
Model NO.
H-CT005-10D
Usage
Distribution Transformer
Frequency Characteristics
Low Frequency
Shape of Core
Ring
Brand
E-Power
Model
H-CT005-10d
Diameter
10mm
Current Ratio
20A/10mA
Rate Primary Current
20A
Max Primary Current
24A
Secondary Turns
2000
Wire Lead
AWG#22
DC Resistance
460ohms +/-20% at 20
Frequency
50/60Hz
Manufacturer
Jiaxing Haihan Electron Co.,Ltd
Trademark
E-Power
Transport Package
Standary Export Carton.
Specification
50*40*30cm
Origin
China
HS Code
8504500000
The H-CT005 Series are split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These current transformer's can be mounted without removing existing cables for easier installation.

1, Electrical Specifications

Model
Current ratio

Current  range

Turn ratio

Rate primary

Max primary

secondary current

Load resistance

Accuracy
H-CT005-10D
5A/2.5mA

0-6A

2000:1

5A

6A

2.5mA

50Ω

0.5Class

20A/10mA

0-24A

2000:1

20A

24A

10mA

20Ω

0.5Class

50A/20mA

0-60A

2500:1

50A

60A

20mA

20Ω

0.5Class

60A/20mA

0-72A

3000:1

60A

72A

20mA

100Ω

0.5Class

60A/30mA

0-72A

2000:1

60A

72A

30mA

100Ω

0.5Class



1), Rated Primary Current(AMP. ) 50/60Hz: 50nom(1~42A max)

2), Max. Current (continuous): 60A

3), Turn ratio: Np: Ns=1: 2000

4), Current Ratio: 50A/0.333V

5), D. C. Resistance Max at 20 º C: 460 Ω

6), Accuracy@RL≤ 10Ω : 1%

7), Linearity@RL≤ 10Ω : 0.5%

8), Phase error at rated current range: ≤ 4°

9), Operating Temperature Range: -25~65º C

10), Storage Temperature Range: -35~85º C

11), Dielectric Withstanding Voltage(Hi-pot): 2.5KV/1mA/1min

12), Impulse Withstand Voltage: 5KV Peak

13), Insulation Resistance: DC500V/100MΩ Min

2, Applications.
A, Portable/Curret instruments.

B, Sub-metering.

C, Monitor Motor Loads

3, Feature
A, Small size.

B, Low cost

C, High secondary turns.

D, Secure locking hings

E, Full RoHS compliant

F, Mounting easy.