N2xs2y Na2xs2y 6/ 10kv 18/30kv Medium Voltage Cable with XLPE Insulation

China N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation, Find details about China Na2xs2y, N2xs2y from N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation

Model NO.
N2XS2Y
Wire Core Material
Copper or Aluminum
Certification
ISO, CCC, CE, RoHS
Model
N2xs2y / Na2xs2y
Brand
Hongda
Armour
Steel Wire/Tape Armour/No
Conductor Material
Copper/Aluminum
Standard
IEC 60502-1
Quality Guarantee
Ten Years
Core
1core/Multicore
Insulated Color
as Your Requirement
Sheath Color
Black
Sample
Yes
Manufacture
Yes
Trademark
Hongda
Transport Package
Wooden Drum
Specification
single core power cable
Origin
China, Henan
HS Code
8544601200
Model NO.
N2XS2Y
Wire Core Material
Copper or Aluminum
Certification
ISO, CCC, CE, RoHS
Model
N2xs2y / Na2xs2y
Brand
Hongda
Armour
Steel Wire/Tape Armour/No
Conductor Material
Copper/Aluminum
Standard
IEC 60502-1
Quality Guarantee
Ten Years
Core
1core/Multicore
Insulated Color
as Your Requirement
Sheath Color
Black
Sample
Yes
Manufacture
Yes
Trademark
Hongda
Transport Package
Wooden Drum
Specification
single core power cable
Origin
China, Henan
HS Code
8544601200

N2XS2Y NA2XS2Y 6/10kV 18/30kV Medium voltage cable with XLPE insulation

Application:
The cables are suitable for installation indoors, outdoors, in the ground and in water. Installation to be carried out in the ground or in a cable channel.
 
CHARACTERISTICS:
Voltage Rating:  (Uo/U)(Um) 6/10 (15)kV, 12/20 (24)kV, 18/30 (36)kV
Test Voltage: 21kV, 42kV, 63kV
Temperature Rating -20°C to +70°C
Minimum Bending Radius 15 x overall diameter
Sheath Colour Black
N2XS2Y / NA2XS2Y Copper / Aluminium Conductor XLPE PE-Medium voltage Cable
CONSTRUCTION:
N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation
1. ConductorCopper / Aluminum conductor
2. Conductor screenInner semi-conducting layer
3. InsulationXLPE insulation
4. Insulation screenOuter semi-conducting layer
5. TapeConductive tape
6. Metallic shieldCopper wire screen and copper tape
7. Non-conducting tape
8. Outer sheathPE outer sheath

Technical details:
 
Number of cores and nominal cross sectionOverall diameter appr.Overall diameter max. valueWeight appr.
N2XS2Y cableNA2XS2Y cable
mm2mmappr. mmkg/km
N(A)2XS2Y 6/10 kV
1 x 35 RM/162328820,0600,0
1 x 50 RM/162429960,0670,0
1 x 70 RM/1626311.150,0770,0
1 x 95 RM/1627321.450,0880,0
1 x 120 RM/1629341.700,0950,0
1 x 150 RM/2530352.000,01.150,0
1 x 185 RM/2532372.350,01.250,0
1 x 240 RM/2534392.900,01.500,0
1 x 300 RM/2536413.550,01.700,0
1 x 400 RM/3540454.500,02.100,0
1 x 500 RM/3543485.550,0 
N(A)2XS2Y 12/20 kV
1 x 35 RM/1627321.000,0 
1 x 50 RM/1628331.150,0820,0
1 x 70 RM/1630351.350,0930,0
1 x 95 RM/1631361.600,01.050,0
1 x 120 RM/1633381.850,01.150,0
1 x 150 RM/2534392.250,01.350,0
1 x 185 RM/2536412.600,01.500,0
1 x 240 RM/2539443.150,01.750,0
1 x 300 RM/2541463.800,02.000,0
1 x 400 RM/3544494.750,02.350,0
1 x 500 RM/3547525.800,0 
N(A)2XS2Y 18/30 kV
1 x 50 RM/1633381.350,01.100,0
1 x 70 RM/1635401.600,01.200,0
1 x 95 RM/1636411.900,01.350,0
1 x 120 RM/1638432.200,01.450,0
1 x 150 RM/2544442.550,01.700,0
1 x 185 RM/2556462.950,01.850,0
1 x 240 RM/2543483.500,02.050,0
1 x 300 RM/2546514.150,02.350,0
1 x 400 RM/3549545.150,02.800,0
1 x 500 RM/3552576.200,0 

N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation

Medium Voltage cables, or MV cables, is a category defined by the International Electrotechnical Commission (IEC) as having a voltage rating of above 1kV up to 100kV. There does, however, remain some ambiguity over where the medium voltage cable band begins and ends, depending on the countries, the standard setting bodies, and the type of system used as historically engineers only referred to low voltage and high voltage. The concept of medium voltage was only introduced as the level of voltages increased and the need arose for a greater classification range, which now often includes extra low and extra high voltage.

Hongda Cables is a leading supplier of medium voltage cables, which we consider to range between 3.3kV and 45kV. For higher voltages, please visit our high voltage cable specifications to find the right cable for your application.  Our MV XLPE insulated cables are manufactured in accordance with various British and international Standards. These include armoured cable to British Standard BS6622 and BS7835; international Standards including IEC 60502-1 and IEC 60502-2; as well as a wide range of international construction specifications, including N2SXY, N2XS2Y, N2XSEY, NA2XSY and NA2XS2Y.

Voltage Rating for some of our most commonly supplied MV cables (always in production):

British Standard MV cablesVoltage Rating
BS6622 - standard British MV cable6.35/11kV19/33kV 
BS7835 - LSZH British MV cable6.35/11kV19/33kV 
European standard MV cablesVoltage Rating 
N2XSY - single copper core XLPE insulated with PVC oversheath6/10kV12/20kV18/30kV
N2XS2Y - single copper core XLPE insulated with PE oversheath6/10kV12/20kV18/30kV
NA2XSY - single aluminium core XLPE insulated with PVC oversheath6/10kV12/20kV18/30kV
NA2XS2Y - single aluminium core XLPE insulated with PE oversheath6/10kV12/20kV18/30kV
N2XSEY - 3 copper core XLPE insulated with PVC oversheath6/10kV  
N2XS(F)2Y - single copper core XLPE insulated with water blocking powder and PE oversheath6/10kV12/20kV18/30kV
N2XS(FL)2Y  - single copper core XLPE insulated with water blocking powder and aluminium tape tightly bonded to PE sheath6/10kV12/20kV 
NA2XS(F)2Y - single aluminium core XLPE insulated with water blocking powder and PE oversheath6/10kV12/20kV18/30kV
NA2XS(FL)2Y - single aluminium core XLPE insulated with water blocking powder and aluminium tape tightly bonded to PE sheath6/10kV12/20kV18/30kV

European MV cable type designation

NMV cable according to DIN VDE 0276
AAluminium (Al) conductor
[blank]Copper (Cu) conductor
2XCross-linked polyethylene (XLPE) insulation
SScreen of copper wires and copper tape, helically wound
SEScreen of copper wires and copper tape over each individual core, helically wound
YPolyvinyl Chloride (PVC) sheath
2YPolyethylene (PE) sheath
(F)2YLongitudinal water tightness with PE sheath
(FL)2YLongitudinal and transversal water tightness with Al/PE sheath

Our MV cables are available in specific lengths as well as in extended long lengths to facilitate installation and to reduce the number of joints. 

Custom designed medium voltage cables

In addition to standard medium voltage cables, we can design and supply bespoke MV cable products developed for your specific applications. Our custom designed cable solutions provide for variants developed and manufactured around a number of parameters, including:

Cross-sectional area: generally 35mm2 up to 100mm2
Number of cores: generally one or three
Solid or stranded aluminium conductors: for applications requiring a lighter cable weight, also often more economical due to lower aluminium prices. 
Stranded copper conductors: for applications requiring a smaller overall diameter and higher transmitting properties.
Bedding
Bonded or strippable out semi-conducting layer
Water tightness: longitudinal, longitudinal + quasi-radial, longitudinal + radial
Insulation layers (conductor screen, insulation and insulation screen): XLPE, which is more commonly used for MV cables, or EPR which is more flexible and often better suited to marine and offshore applications.
Metallic screen: to nullify the electric field outside the MV cable. Concentric copper wire screens, Aluminium foil laminate, or extruded lead alloy sheath.
Twisted three-core cable or triplex 
Armouring: for mechanical protection. Aluminium wire armoured for single-core cables, Galvanised steel wire armour, strip or tape.
Tapes: Separator tapes to facilitate peeling, water-swellable tapes to prevent water ingress, Conductive tape for core binding.
Outer Sheath: compounds with various properties, tailored to the specific application's requirements, including resistance to oils, greases, rodents, termites, UV and flame, as well as zero halogen emissions.

Medium Voltage cable testing

Some of the tests you would expect from a medium voltage cable manufacturer, and which are performed on our MV cables, include:

Routine tests: These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath

Sample tests: These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test

Type tests: These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.
 
N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation



Packaging&Delivery.
 N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation


Packaging Details:
Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 30 days(detailly depend on the order quantity)

Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.
Vivian Yuan
Mobile:+86 15838290725