China Hot Sale CT PT Turn Ratio Polarity Tester Meter Test Machine, Find details about China CT Analyzer, CT Analyzer Price from Hot Sale CT PT Turn Ratio Polarity Tester Meter Test Machine
Type | ZC-102F | |
Application | Test CT: excitation characteristics, variable ratio, polarity, ratio error and angle error etc. Test PT: excitation characteristics, ratio, polarity, secondary winding resistance, ratio error, etc. | |
Working power supply | Input voltage | 185Vac~250Vac |
Allowable Input Voltage | 85Vac~264Vac | |
Frequency | 50/60Hz | |
Allowable frequency | 45Hz~65Hz | |
Input power | 5000VA | |
Connector | Standard AC socket 60320 | |
Built-in booster | Output range | 0~2500V(220V power) |
0~20A | ||
Volt-ampere characteristic test reference load capability | 1A/2500V | |
2A/1500V | ||
5A/600V | ||
10A/220V | ||
20A/30V | ||
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.5 class Variable Ratio Measurement Accuracy: 0.5 class | |
External booster | Output range | 0~4000V/1A |
Volt-ampere characteristic test reference load capability | 1A/4000V | |
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.5 class Variable Ratio Measurement Accuracy: 0.5 class | |
Up-flow Reactor | Output range | 0~600A |
Volt-ampere characteristic test reference load capability | 800VA | |
Measurement Accuracy | Variable Ratio Measurement Accuracy:<1% | |
Environment condition | Operating temperature | -10ºC~+50ºC |
Storage temperature | -25ºC~+70ºC | |
Relative humidity | 5%~95%,No condensation | |
Physical characteristics | Size | 425×300×290mm3 |
Weight | ≈26kg(not include accessories ) |