Battery Pack for storage

China Battery Pack for storage, Find details about China Lithium Battery Li-ion Battery, LFP LiFePO4 from Battery Pack for storage

Model NO.
AP48100
Rated Capacity
50ah 100ah
Standard Voltage
48V
Usage
Home storage Ess Bess
Electrolyte
Li-ion
Trademark
Allsparkpower
Transport Package
Standard Export Package
Specification
LFP 48V 100Ah
Origin
China
HS Code
8504402000
Model NO.
AP48100
Rated Capacity
50ah 100ah
Standard Voltage
48V
Usage
Home storage Ess Bess
Electrolyte
Li-ion
Trademark
Allsparkpower
Transport Package
Standard Export Package
Specification
LFP 48V 100Ah
Origin
China
HS Code
8504402000
ItemparametersNote






Cell
TypeLiFePO4 Battery 
Cell ModelLF50116160-100 LFP
Nominal Capacity100AhDischarge : 0.5C Cut-off Voltage:2.5V
Minimum Capacity100AhDischarge : 0.5C Cut-off Voltage: 2.5V
Nominal voltage3.2V 
Internal Impedance1.5mΩ 
DimensionMax.49.9x116x160mm 
WeightApprox.1.95kg  




















Batterypack
Pack Method15S1P 
Nominal Capacity100AHDischarge : 0.5C
Cut-off Voltage:37.5V
Minimum Capacity100AHDischarge : 0.5C
Cut-off Voltage: 37.5V
Nominal Voltage48V 
Energy4800Wh 
Charge Voltage54.75V 
Discharge cut-off voltage37.5V 
Charge MethodCC/CV 
Standard Charge
Current
50A 
Max. Charge Current100A 
Standard Discharge
Current
50A 
Max. Continues
Discharge current
100A 
Cycle Life3500 times() 
Internal Impedance15mΩ 
DimensionL482(L1
442)xW420Xh177.5mm
 
Output Wire/ 

Output Connector
UES0601LBNBA ,25
,,6.0 ,
Charge discharge port
CommunicationRS485/RS232/CAN 
 
 
 
  
 
Weight
Approx.48kg 
Working Temperature RangeCharge: 0°C--45°C Discharge: -20°C--60°C 
Storage Temperature-10°C--50°C 
 
  1. BMS BMS Parameters
    1. main parameters setting

No.

Item
Default parameters
Setting or not

note





1

Cell overcharge protection
Alarm voltage3600mVYes 
Protection voltage3700mVYes
Protection time delay4.0SYes
Cell overcharge protection releasedReleased voltage3380mVYes
Released CapacitySOC<96%Yes
Discharging releasedDischarging current > 1A



2
Cell over discharge protectionAlarm voltage2800mVYes
After 30 seconds of over‐discharge protection, if it still cannot be recovered, it will enter the low
Protection voltage2500mVYes
Protection time delay1.0SYes
Cell over discharge protection releasedReleased voltage2900mVYes
ChargingConnect with charger




3

Pack overcharge protection
Alarm voltage54VYes 
Protection voltage55.5VYes
Protection time delay4.0SYes
Pack overcharge protection releasedReleased voltage50.7VYes
Released CapacitySOC<96%Yes
Discharging releasedDischarging current > 1A



4
Pack over discharge protectionAlarm voltage42VYes
After 30 seconds of over‐discharge protection, if it still cannot be recovered, it
will enter the low
Protection voltage37.5VYes
Protection time delay1.0SYes
Pack over discharge protection releasedReleased voltage43.5VYes
ChargingConnect with charger


5
Over charge current protectionAlarm current105AYes10 times consecutive occurrences will lock this state and will no longer be automatically released
Protection current110AYes
Protection time delay1.0SYes
Released over charge current protectionAutomatic releaseAfter 1min
  ChargingDischarging current > 1A 





6
Over discharge current protection 1Alarm current105AYes
10 times consecutive occurrences will lock this state and will no longer be automatically released
Protection current110AYes
Protection time delay1.0SYes
Released over discharge current protection 1Automatic releaseAfter 1min
       
 
 
  Charging releaseDischarging current > 1A 



7

Over discharge current protection 2
Protection current150AYes10 times consecutive occurrences will lock this state and will no
longer be automatically
Protection time delay100mSYes
Released over discharge currentAutomatic releaseAfter 1min
Charging releaseDischarging current > 1A 



8

short‐circuit protection
Protection current≥350A 
Protection time delay≤300μS

Protection released
charging
Off load

9
MOS High temperature
protection
Alarm temperature90ºCYes 
Protection Temperature110ºCYes
Released temperature85ºCYes













10













Cell temperature protection
Low temperature charging0ºCYes 
Low temperature charging Protection‐5ºCYes
Low temperature charging Protection released0ºCYes
High temperature charging alarm55ºCYes
High temperature charging Protection60ºCYes
High temperature charging Protection released50ºCYes
Low temperature
discharging alarm
‐15ºCYes 
Low temperature discharging Protection‐20ºCYes
Low temperature
discharging Protection
‐15ºCYes
High temperature discharging alarm60ºCYes
High temperature
discharging Protection
65ºCYes
High temperature discharging Protection55ºCYes






11
Ambient temperature protectionLow temperature alarm‐15ºCYes 
Low temperature protection‐20ºCYes
Low temperature protection
released
‐15ºCYes
high temperature alarm65ºCYes
High temperature75ºCYes
High temperature protection released65ºCYes
 Current consumption
Working self‐consumption
≤45mA(with display) 
 
 
12 current≤40mA(without display) 
Low Energy running mode≤100μA

13

Balancing
Pack voltage difference3500mVYesopen
Cell Voltage difference30mVYes
14Default capacityLow capacity alarmSOC<5%YesThere is no alarm when charging
15Sleep featuresleep Voltage3150mVYes 
Time delay5minYes 

3.2.LED LED instruction

Table 1    LED Working status indicator


 
 
Status
Normal/Alarm
/Protection
ON/ OFFRUNALMLED status 
Note
         
ShutdownSleepOffOffOffOffOffOffOffOffOffAll off

Standby
NormalNormally onflicker 1Off
The battery capacity status
 
AlarmNormally onFlicker1Flicker3Low voltage






Charging
NormalNormally onNormally onOff
The battery capacity status ( max capacity LED flicker 2)
Over charge status, the ALM light will not flicker
AlarmNormally onNormally onFlicker3

Over charge protection
Normally on
Normally on

Off
ononononononIf no charging, the LED status will be standby
Temperature,over current , failure protectionNormally on
Off

Normally on

Off

Off

Off

Off

Off

Off

Stop charging
 
 

Discharging
NormalNormally onFlicker3Off
The battery capacity status
 
AlarmNormally onFlicker3Flicker3
Low voltage protectionNormally onOffOffOffOffOffOffOffOffStop discharging
Temperature,over current , failure protectionNormally on
Off

Normally on

Off

Off

Off

Off

Off

Off

Stop discharging
Failure OffOffNormally onOffOffOffOffOffOffStop charging or discharging
 
Table    2    battery capacity status specification
 
status chargingdischarging


Capacity LED light
L6
 
L5
 
L4
 
L3
 
L2
 
L1
 
L6
 
L5
 
L4
 
L3
 
L2
 
L1
 





capacity(%)

0~16.6%

Off

Off

Off

Off

Off

F2

Off

Off

Off

Off

Off

ON 1
16.6~33.2%OffOffOffOffF2On 1OffOffOffOffOn 1On 1
33.2~49.8%OffOffOffF2On 1On 1OffOffOffOn 1On 1On 1
49.8~66.4%OffOffF2On 1On 1On 1OffOffOn 1On 1On 1On 1
66.4~83.0%OffF2On 1On 1On 1On 1OffOn 1On 1On 1On 1On 1
83.0~100%F2On 1On 1On 1On 1On 1On 1On 1On 1On 1On 1On 1
Running LED Normally onF3
Note: F2: flicker 2 ; On 1: normally on ; F3: flicker 3

Table    3    LED flicker status
Flicker modelonoff
Flicker 10.25S3.75S
Flicker 20.5S0.5S
Flicker 30.5S1.5S
 
    1. Description of buzzer action
Fault: Every second, Buzzer works 0.25S;
Protection: Every 2 seconds, Buzzer works 0.25S;(except over voltage protection) Alarm: Every 3 seconds, Buzzer works 0.25S;(except over voltage protection)
The buzzer function can be enabled or disabled by the host computer, and the factory default is disabled.
    1. Buttons Description
When the BMS is in the sleep state, press the button (3~6S) and release, the protection board is activated, and the LED indicator lights up in sequence from "RUN" for 0.5 seconds.
When the BMS is activated, press the button (3~6S) and release it, the protection board is dormant, and the LED indicator lights up in order from the lowest battery light for 0.5 seconds.
When the BMS is in the activated state, press the button (6~10S) and release it, the protection board is reset, and the LED lights are all lit simultaneously for 1.5 seconds.
After the BMS is reset, the parameters and functions set by the host computer are retained. If you need to restore the initial parameters, you can use the "restore default value" of the host computer to achieve, but the related operating records and stored data remain unchanged (such as power, cycle number, Record protection, etc.)
    1. Sleep and wake up status
      1. Sleep status
When any of the following conditions are met, the system enters a low‐power mode:
  1. The single or overall over‐discharge protection has not been released within 60 seconds.
  2. Press the button (3~6S) and release it.
  3. The lowest monomer voltage is lower than the sleep voltage, and the duration reaches the sleep delay time (at the same
 
time, no communication, no protection, no balance, no current).
  1. Standby time exceeds 24 hours (no communication, no charge and discharge, no commercial power).
  2. Forced shutdown by the host computer software. Before entering sleep, make sure that the input terminal is not connected to an external voltage, otherwise it will not be able to enter the low power consumption mode.
      1. Wake up status
When the system is in low‐power mode and meets any of the following conditions, the system will exit low‐power mode and enter normal operation mode:
        1. Connect the charger, and the charger output voltage must be greater than 48V.
        2. Press the button (3~6S) and release it.
        3. RS232 communication is activated (this method cannot wake up the motherboard due to over‐discharge).
Remarks: After single or total over‐discharge protection enters low power consumption mode, it wakes up regularly every 4 hours and turns on charge and discharge MOS. If it can be charged, it will exit the sleep state and enter normal charging; if it can not be charged after 10 consecutive automatic wakeups, it will no longer automatically wake up.
When the system is defined as the end of charging, the recovery voltage has not been reached after 2 days of standby (standby time setting value), and the charging is forced to resume until the end of recharging.

 
  1. Appearance
,,,,,,.
It shall be free from any defects such as scratch, distortion, contamination and leakage.

 
  1. Performance
    1. Standard Test Condition
,,: :20±5ºC,: 65±20%,,15A ,, 5 ,
The battery shall be evaluated within 1 month from the arrival date.
Unless otherwise stated in these specifications, the following test shall be carried out in an ambient temperature of 20±5ºC, relative humidity of 65±20%
Discharge capacity when the battery is discharged at 15A to 37.5V after being standard charged. Five cycles are permitted for this test. The test shall be terminated at the end of the first cycle which meets the requirement.

 
    1. Testing Instrument or Apparatus
      1. Dimension Measuring Instrument
0.01mm.
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm specified.

 
      1. Voltmeter and Ammeter
10K/V, 0.01. Voltmeters and ammeters shall be equal or more precision instruments of 10K/V and 0.01.
 
      1. Impedance Meter
(1kHz LCR)
Impedance shall be measured by a sinusoidal alternating current method (1kHz LCR meter)


 
    1. Electrical Performance
ItemConditionSpecification

Open-Circuit Voltage
,24
The open-circuit voltage shall be measured within
24hours after standard charge

≥49.5V


Battery Capacity
, 1 , 15A ,
The discharge time at 15A shall be measured after
standard charge at 20±5ºC and rest 30mins


≥100%




Cycle Life
20±5ºC, 50A ,≤0.02C; 1 , 50A ; 1 , 3500 ,The discharge time on standard discharge shall be measured after 3500 cycles of standard charge and discharge at 20±5ºC,0.5C charge and discharge.


≥80%

Charge(capacity) retention
20±5ºC,, 28 ,
15A ,
The discharge time at 15A shall be measured after standard charge and then storage at 20±5 ºC for 28days


≥80%

1 Temperature Characteristic1
, 55±2ºC 5h, 15A ,
After standard charging at 20±5ºC, laying the battery at 55ºC for 2hour, then discharge at 15A to 37.5V, record the discharge time


≥80%

2 Temperature Characteristic2
,-10±2ºC 16-24h, 15A
,
After standard charging at 20±5ºC, laying the battery at
-10 ºC for 4hour, then discharge at 15A to 37.5V, record the discharge time


≥60%
 
  1. Mechanical Performance
ItemConditionSpecification




Crush Test
,32mm , 17.2Mpa, 13KN,
A battery is to be crushed between two flat surfaces. The force for the crushing is to be applied by a hydraulic ram with a 32mm diameter piston. The crushing is to be continued until a pressure reading of 17.2mmPa is reached on the hydraulic ram, applied force of 13kN. Once the maximum pressure has been obtained it is to be released.




,
No fire, No explosion
 
 


Drop Test
1m ,() 1
The battery has only two axes of symmetry in which case only two directions shall be tested. The battery is to be dropped from a height of 1 meter twice onto
concrete ground.

,,
No explosion, No fire, No smoke



Vibration
, X,Y,Z 30 , 1.6mm
A full-charged battery is to be subjected to simple harmonic motion with an amplitude of 1.6mm total maximum excursion. The frequency is to be varied at the rate of 1 hertz per minute between 10 and 55 hertz. The cell shall be vibrated for 30 minutes per
axis o XYZ axes.


,,
No leakage, No Fire, No explosion



 
  1. Cell Safety Performance   
ItemConditionSpecification



Over charge
20±5ºC, 1C 4V,4V 0A,, 10ºC,.
At 20±5ºC, charging battery with constant current 1C
to voltage 4V, then with constant voltage 4V till current decline to 0.


,
No explosion, No fire



Over discharge
.20±5ºC, , 30mΩ 24 .
At 20±5ºC, according to the requirement of the standard of discharge after discharge to termination voltage, 30 m Ω external load discharge within 24
hours.


,,
No explosion, No fire



Short-circuit
20±5ºC,, 50mΩ, 6 .
At 20±5ºC, Standard charge, across the electrodes of the battery with a less than 50 m Ω wire connection, 6 hours
, 150ºC No explosion, No fire The temperature of the surface of the cell are
lower than 150ºC


Heating
, 5±2ºC, 130ºC, 30
Battery is heated in a circulating air oven at a rate of 5±2ºC per mins to 130ºC, an then placed 30 mins at
130ºC


,
No explosion, no fire
 
  1. Delivery Conditon  
, 20-50%,,,:48.75-50.1V
Approx. 20-50% charged Shipment voltage: 48.75-50.1V