Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

China Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection, Find details about China Accumulator Tank, Accumulator from Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

Model NO.
TK-ITW-50L-004
Power
Pneumatic
Start Up
Start Pump
Type
Jet Pump
Application
Submersible Pump
Industry
Food Pumps
Media
Water
Performance
Sanitary Pumps
Theory
Jet Pump
Nominal Volume
50 Liter
Useful Volume Max
40 Liter
Max. Working Pressure
10 Bar
Max. Temperature
99 °c
Factory Air Pre-Charge
4 Bar
Pre-Charged Gas
Nitrogen Gas
Shell
Carbon Steel Body
Tank Shell Treatment
Epoxy Polyester Paint
Connections
Carbon Steel Flange G 1 1/2"
Membrane
Interchangeable Rubber Membrane
Vessel Color
Ral 5015 Sky Blue/
Vessel Diameter
410 mm
Vessel Height
610 mm
Test Pressure
15 Bar
Orientation
Horizontal
Trademark
Aqualeader/Dezhi
Transport Package
Paper Box
Specification
10/16/20/25/35 BAR Wroking Pressure
Origin
Taizhou, China
HS Code
8413609090
Model NO.
TK-ITW-50L-004
Power
Pneumatic
Start Up
Start Pump
Type
Jet Pump
Application
Submersible Pump
Industry
Food Pumps
Media
Water
Performance
Sanitary Pumps
Theory
Jet Pump
Nominal Volume
50 Liter
Useful Volume Max
40 Liter
Max. Working Pressure
10 Bar
Max. Temperature
99 °c
Factory Air Pre-Charge
4 Bar
Pre-Charged Gas
Nitrogen Gas
Shell
Carbon Steel Body
Tank Shell Treatment
Epoxy Polyester Paint
Connections
Carbon Steel Flange G 1 1/2"
Membrane
Interchangeable Rubber Membrane
Vessel Color
Ral 5015 Sky Blue/
Vessel Diameter
410 mm
Vessel Height
610 mm
Test Pressure
15 Bar
Orientation
Horizontal
Trademark
Aqualeader/Dezhi
Transport Package
Paper Box
Specification
10/16/20/25/35 BAR Wroking Pressure
Origin
Taizhou, China
HS Code
8413609090
s40 Cuztomized Export Model is the model for Export Only,In order to protect our oversea area dealers ,no sales to inside China ,only direct export to authorized countries.Or you can find the equivalent model from our open models

Please contact Mr.Tom Lee For details


Yours Attentions ,please 

Why do I need an accumulator tank?


An accumulator tank is an important part of any pressurised water system that includes a pressure-controlled pump. (Some modern computer-controlled pumps may not require an accumulator tank) Fitted close to the discharge port of the pressurised water pump, the accumulator tank acts as a pressure buffer, ensuring a smooth flow of water from the outlets. Without an accumulator tank, the pump is liable to switch itself rapidly on and off whenever its flow rate exceeds demand from the outlets. Constant on-off cycling leads to increased pump wear and unnecessary battery drain. The accumulator tank stops this rapid cycling, resulting in smooth water flow (important in showers) and an extended pump life.

Where do I fit an accumulator tank?

The accumulator tank should be fitted in the discharge line from the pump, as close as possible to the pump itself (see diagram). The tank will serve no useful function if fitted in the pump inlet pipework.

How do I install an accumulator tank?

The tank should be installed in a dry place. Tanks may be fitted in any attitude, vertical or horizontal. The tank may be secured by stout strapping or by stainless steel bands, or it may be mounted in a wooden cradle. The steel tank casing is robust, but care should be taken during installation not to scratch, dent or puncture it. A special bracket mounting kit (contact Tom for details) is available for the 2 to  40 liter capacity models.
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

What size of accumulator tank do I need?

This depends on the number of outlets in your system, their frequency of use, on the flow rate of the pump and on the space available. The larger the tank, the less frequently the pump will start, and the longer it will run before stopping. Contact Tom Or Other Guys From Taizhou Tianyang Electrical Co., Ltd.  if you require advice.

At what pressure should I set the accumulator tank?

The pressure in the tank is adjusted by means of the air valve in the closed end. The tank is supplied with an internal pressure of about 2.8 bar (35 psi). Reduce this pressure to 2 - 3 psi below the cut-in pressure of the pump (refer to pump instructions for details). This pressure adjustment is best done before installation of the tank, using a car-type pressure gauge to determine when the required pressure is reached, as follows:

(We can add pressure Gauage For 35 liter capacity Or Above,please contact tom for details)

A. Depress the central pin of the Schrader valve with your finger, to release gas

B. Release gas a little at a time, until the pressure is correct

C. If you release too much gas by mistake, air may be pumped back in with a hand - or foot-pump.

WARNING

Make sure that there is adequate ventilation when setting or adjusting pressure in an accumulator tank. Nitrogen is nontoxic, but oxygen levels may be reduced in confined spaces.


If the tank pressure requires adjustment after installation, ensure first that the pump is switched off and that an outlet is open, so that there is no pressure in the system. Then regulate the pressure as indicated above. Check the accumulator tank performance in this way every 3/6 months,depends on air valve you have choosen from us, and adjust the pressure if necessary.
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

There are two main types of Expansion Vessel dependent on what application you have. You will normally find a Red Vessel (Heating Vessels) to be used on a Sealed System Heating application whilst the most common use for a Blue Vessel or White Vessel (Potable Vessels) would be in a potable application such as an Unvented Water Heater or a Pumped System.

Potable Expansion Vessels are built from different materials than Heating Expansion Vessels to ensure that the water is contaminant free and safe for human consumption. Expansion Vessels operate on the basis that the internal chamber is separated by a rubber membrane, inside this membrane sits the water and surrounding this sits a pocket of air--For some models are filled with nitrogen gas up to 99.9% purified. As the water inside the sealed system is heated the water pressure increases, as water is non compressible the air inside the air chamber of the Expansion Vessel will become compressed thus leaving the system safe from over pressurization. As water can increase by 4.5% volume when heated from 0-100 DegC an Expansion Vessel is a vital part of any sealed heating system.

Expansion Vessels can be supplied with a replaceable or fixed membrane depending on your preference and the pressure within the Vessel is set using a Schrader Valve just like you would find on a bicycle tyre.

Expansion Vessels are commonly used on pumped systems to remove the requirements of a continuous pump. This works as the user will set a low and high pressure on the pump settings, when the water pressure reaches the lowest setting the pump will engage and fill the Expansion Vessel to the high pressure point and stop. Once this cycle has been completed the Expansion Vessel puts the stored water under pressure ensuring higher pressure water. This will continue until the Expansion Vessels pressure drops to the lower point and the pump starts its cycle again.

At  Taizhou Tianyang  Electrical Co.,LTD,  we manufacture Expansion Vessels according to afferent requirements from other clients , to help you find the vessel you require please find below contact information of our sales staff,we can make our best offer to you as soon as your details requirements come.

Please find the open model by referring to our catalog.

We have a lot of stock for fast shipment with Dezhi/Auqa Leader Brand.If you have your own drawing for tanks or your own trade mark for OEM Service,feel free to contact us.

Cuztomized Export Model is the model for export ONLY,In order to protect our area oversea dealers ,no sales to inside China ,only direct export .

Description:

An expansion vessel, pre-charged with nitrogen instead of compressed air, to meet the requirements of most heating systems and for use with potable water. The Expansion vessels for potable water systems are manufactured to meet the requirements of PED 97/23/EC Directive and BS EN 13831:2007 'Closed expansion vessels with built in diaphragm for installation in water'.

Why use Nitrogen Instead of Compressed Air?

The oxygen in compressed air permeates through the membrane, reducing the pre charge pressure. During
normal function, oxygen oxidizes the membrane in the vessel, causing under-inflation and deterioration of the rubber.

Dry nitrogen by comparison maintains proper inflation pressure longer, will not corrode the inside of the vessel
and extends valve and expansion vessel life. Industry research indicates that oxidative aging is one of
the primary causes of decreased vessel life. Oxidative aging that is caused by the diffusion of oxygen from the
pressurized air cavity of the vessel to the outside atmosphere.

Tests have shown that if vessels are inflated with nitrogen, there is a significant reduction in failure.

How does Nitrogen help?

While both nitrogen and oxygen can permeate rubber,nitrogen does it much more slowly. It might take 6 months
to lose 2psi with nitrogen, compared to just a month with air. And nitrogen is far less reactive. It doesn't cause rust
or corrosion on steel or aluminum, and it doesn't degrade the rubber seal used in the pre charge valve extending valve core life and help prevent core leaks.

Technical Parameter 
 
NamePotable Water Expansion Vessel
ApplicationFor sanitary hot water systems
Max. working pressure10 bar
Max. temperature:100°C
Factory air pre-charge:2.0 bar nitrogen
Capacity:50 Ltr
Useful Capacity40 Liter
ShellCarbon steel
ConnectionsG Stainless Steel Grade 304
DiaphragmReplaceable
Membrane Material Synthetic rubber compound
Vessel Diameter410 mm
Vessel Height610  mm
Contact PersonMr.Tom Lee (aqualeader.en.made-in-china.com)

Technical Drawing For Your Reference

Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Different Optional Flange/Membrane For Our Dealer Only

Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection


Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Company profile 

Taizhou Tianyang Electrical co., LTD. Is located in Shangma industrial Zone, Shitang Town, WenlingCity, Zhejiang rovince, covering an area of 15, 000 square meters. Our Company has over 30 years experience in mold design and exploition. "DEZHI"and "AQUALEADER" are our proprietary brand of our company. We have produced pressure tank for more than 20 years. Available volumes range from 0.15 to 1500 liters. and working pressure from 4 bar to 25bar. Our products are applied to pump systems. Our products are exported to numerous overseas clients. We can custom design and manufacture products according to client-supplied requirements. 
We adhere to the business philosphy"Credibility, Quality and service", our scientific management is based on the domestic market, but facing to the world. Warmly welcome customers both domestic and from abroad. We sincerely hope to cooperate and develop together to create a better future. 
Taizhou Tianyang Electrical Co., Ltd. Is always your most loyal partner.  

Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

I would like to take this opportunity to introduce our company to you. I am contacting you on behalf of Taizhou Tianyang Electrical Co., LTD.

We are the factory from China for making Pressure Tanks for Fire Protection, Residential Water and Irrigation, Sport Turf and Landscape Irrigation, Agriculture and Horticulture Irrigation, Water Filtration, Treatment & Recycle, Solar and Stock Water System, Rain Water Harvesting, Pump Systems. Based on ISO quality management system, we have obtained CE, KC, ISO 9001, ISO14001, OHSAS 18001, SGS, Water Mark, and Wras Certificates for our company & our Pressure Tanks. Welcome to visit Taizhou Tianyang Electrical Co., LTD when it is more convenient for you. 

Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection

FAQ Details:  

1. Q: What is your MOQ of this item?
  A: We are a factory, have stock. 1PCS is ok!

  2. Q: What is the delivery time?
  A: 7-25 days after receiving orginal L/C or deposit by TT.

  3. Q: Is it all right to make customer's own brand name?
  A: Yes we supply OEM service. Please send us a authorization doc.

  4. Q: Where is your Loading Port?
  A: Ningbo, Zhejiang, China.

  5. Q: What are your payment terms? For Bulk Quantity Purchase
 A: 30% deposit and balance T/T against copy of Bill of Lading or L/C at sight.
  For Samll amount Trial Order, Please arrange the full payment

  6. Q: What is your company's available production capacity?
  A: 50000~60000 pieces of Pressure Tank per month. 

Welcome To Visit Us 

Please do not hesitate to contact me if you have any questions.  

Aqua Leader 50 Litre Potable Expansion Vessel with 1" Connection
Yours Sincerely 

Tom Lee

-----------------------------------------------------------
Tom Lee 
Business Development Manager
Taizhou Tianyang Electrical Co., LTD
Ph: +86-21-57813120
 
Fax: +86-576-86818392
aqualeader.en.made-in-china.com