Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1

China Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1, Find details about China AVR, R450t from Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1

Model NO.
SSAYEC432 LSA461901, LSA461-09-01, LSA461-9-01
Stock
Yes
Gross Weight
0.8kg
Warranty
1 Year
Specification
14.5*10*6 cm
Origin
Fuzhou
HS Code
8503009090
Model NO.
SSAYEC432 LSA461901, LSA461-09-01, LSA461-9-01
Stock
Yes
Gross Weight
0.8kg
Warranty
1 Year
Specification
14.5*10*6 cm
Origin
Fuzhou
HS Code
8503009090

R450T AVR is powered by two auxiliary windings which are independent of the voltage equal circuit. The power supply voltage is rectified and filtered before being used by the AVR monitoring transistor. With PMG excitation, a permanent magnet generator (PMG) added to the alternator supplies the AVR with voltage.

On Application of load, the rotation speed of the generator set deceases, when it passes below the preset frequency threshold the LAM causes the voltage to drop by approximately13% or 25% and consequently the quantity of active load applied is reduced by approximately 25% to 45%, until the speed reaches its rated value again. Hence the LAM can be used either to reduce the speed variation (frequency) and its duration for a given applied load, or to increase the applied load probable for one speed variation (turbo-charged engine).

1. Leroy SomerAutomatic Voltage Regulator R450

2. Single or three phase voltage sensing with optional module.
3. Load acceptance module, PMG / AREP excitation system
4. Phase to phase voltage sensing.
5. Suitable for high levels of vibration and harsh environments      

Main characteristics:

Voltage regulation +/- 0.5% at steady state and constant speed.

 Control by transistor means that the regulation quality is independant of applied load.

Phase to phase voltage sensing.

Suitable for high levels of vibration and harsh environments.

Integrated "LAM" and " auto adaptative LAM" system to cope with load impacts applied to the engine

AREP or PMG excitation with normal or fast response.

Single or three phase voltage sensing with optional module.

Rotating switch facilitating selection.

 

 Voltage 230± 2V 
 Voltage Steady Range ± 1V
 Starting Excitation Voltage ≥1.5V 
 Loading Capacity With 110% loading, the regulator can work normally
 Output Voltage Steady on hot and cool condition ≤2V 
 Temperature float on Output Voltage ≤2V 



Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1
Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1
Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1
Leroy Somer Generator Alternator Diode 82pfr80 and 82PF80 Diode Bridge 330-25777 Alt411kd001 Lsa432-442 Diode Bridge 922-220 Cii111pm004 Rectifier Diode Lsa49.1