Power Distribution Pole Mounted Vacuum Automatic Circuit Recloser 12kVThe AR-3S-33 series circuit reclosers are recently-developed pole-mounted intelligent vacuum circuit reclosers of a new generation, which absorb the advanced domestic and foreign technologies adopted by our company. It is
intelligent, energy-saving, environemntally-friendly and maintenance-free.
This product integrates such functions as control, protection, measurement, fault positioning, online monitoring and synchronous closing. With full functions and high digitalized and intelligent degree, it is a best choice for power distribution equipment network automation and intellectualization process.
This product conforms to
IEC60044-1, IEC60060, IEC60068-2, IEC60099-4, IEC60255-27, IEC60270, IEC60280.1, IEC60529, IEC60694, IEC60815-1, IEC60870-5-101, IEC61000-4, IEC61243-5, IEC62271, standards, etc.
Major Technical Parameters are shown below:
Rated voltage | kV | 12 | 24 | 40.5 |
Rated current | A | 630/800 | 630/800 | 800 |
Rated frequency | Hz | 50/60 | 50/60 | 50/60 |
1min power frequency withstand voltage | kV | 42/48 | 65/79 | 70 |
Lightning impulse withstand voltage | kV | 75/85 | 125/150 | 170 |
Rated short circuit breaking current | kA | 16 | 20 | 20 |
Rated short circuit making current | kA | 31.5 | 40 | 40 |
Rated peak withstand current | kA | 31.5 | 40 | 40 |
Rated short time withstand current, 3s | kA | 16 | 20 | 20 |
Operations of short-circuit breaking current interruption | times | 30 | 30 | 30 |
Mechanical life | times | 30,000 | 30,000 | 30,000 |
Operation sequence | | O-0.3s-CO-3s-CO-3s-CO |
Our advantages:
1. Most parts are manufactured ourselves, like: frame, cabinet, permanent magnet mechanism, insulation part, control panel, etc. That means the process quality control is effectively controlled.
2. Adopt fast algorithm with patent technology (patent number: ZL200720037710.7) so as to obtain fast breaking capacity of circuit breaker. As a result, it can isolate fault circuit rapidly. It takes less than 25ms from inspecting fault to cut fault circuit by separate circuit breaker. It can avoid the problem of override trip effectively.
3. Adopt single phase earthing protection system with patent technology (patent number: ZL201020178325.6). It can realize on-line judgment to single phase earthing fault of low current earthing system without adding device. Releases warning or tripping action according to setting valueOur service:
1. Pre-sale technical support, training;
2. On-site factory inspection is accepted;
3. Open atitude for cooperation;
4. Punctual goods delivery;
5. After-sale technical support and service.