1200 AMP Split Core Current Transformer Ct's with 0.2 0.5 Class

China 1200 AMP Split Core Current Transformer Ct′s with 0.2 0.5 Class, Find details about China 0.2 0.5 Class Current Transformer, 0.2 Split Core Ct′s from 1200 AMP Split Core Current Transformer Ct′s with 0.2 0.5 Class

Model NO.
LZCK-55
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Key Words
CT Analizer Eltel
Accuracy
0.5s, 0.5%, 1%, 3%
Rated Voltage
35kv
Range of Primary Rated Current
100-1500A
Range of Rated Load
≤10va
Rated Frequency
50/60Hz
Rated Secondary Current
5A or 1A
Aperture (mm)
Φ55
Output Signal
1A, 5A, 333mv, 1V or 5V(Customized)
Model
High Frequency Current Transformer
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
180mm× 138mm× 52mm
Origin
Beijing, China
Model NO.
LZCK-55
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Key Words
CT Analizer Eltel
Accuracy
0.5s, 0.5%, 1%, 3%
Rated Voltage
35kv
Range of Primary Rated Current
100-1500A
Range of Rated Load
≤10va
Rated Frequency
50/60Hz
Rated Secondary Current
5A or 1A
Aperture (mm)
Φ55
Output Signal
1A, 5A, 333mv, 1V or 5V(Customized)
Model
High Frequency Current Transformer
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
180mm× 138mm× 52mm
Origin
Beijing, China
Product Description
LZCK55 USA high frequency hobut split core  current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1500A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2
Working conditions
Operating temperature-35°C to +65°C, not exceeding +40°C
Storage temperature-40°C to +70°C
Ingress ProtectionIP65
Environmentoutdoors or indoors
The Height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.