IP65 400 5A Split Core CT Clamp CT Transformer

China IP65 400 5A Split Core CT Clamp CT Transformer, Find details about China Clamp CT Transformer, Split Core CT from IP65 400 5A Split Core CT Clamp CT Transformer

Model NO.
LZCK-55
Insulating Medium
Common Insulating Materials
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Types
Split Core Outdoor CT
Accuracy Class
0.5s, 0.5%, 1%, 3%
Range of Primary Rated Current
100-1500A
Range of Rated Load
≤10va
Rated Secondary Current
5A or 1A
Safety Factor Rating
(Fs) <10
Aperture (mm)
Φ55
Trademark
gfuve
Transport Package
Standard Carton Box
Specification
Dimensions (mm) 180× 138× 52
Origin
Beijing China
HS Code
85043110
Model NO.
LZCK-55
Insulating Medium
Common Insulating Materials
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Types
Split Core Outdoor CT
Accuracy Class
0.5s, 0.5%, 1%, 3%
Range of Primary Rated Current
100-1500A
Range of Rated Load
≤10va
Rated Secondary Current
5A or 1A
Safety Factor Rating
(Fs) <10
Aperture (mm)
Φ55
Trademark
gfuve
Transport Package
Standard Carton Box
Specification
Dimensions (mm) 180× 138× 52
Origin
Beijing China
HS Code
85043110
100/ 5a Clamp Outdoor Waterproof Split Core CT  
LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.

PARAMETERS

Technical parameters
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1500A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2
Working conditions
Operating temperature-35°C to +65°C, not exceeding +40°C
Storage temperature-40°C to +70°C
Ingress ProtectionIP65
Environmentoutdoors or indoors
The Height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

SELECTION GUIDE

 ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PC IP65
LMCK185-10300-3000A≤25VAφ185350×283×554.5PC IP65
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)
IP65 400 5A Split Core CT Clamp CT Transformer
IP65 400 5A Split Core CT Clamp CT Transformer