400/5A 10va IP65 Outdoors Split Core CT Current Transformer

China 400/5A 10va IP65 Outdoors Split Core CT Current Transformer, Find details about China Current Transformer, Split Core CT from 400/5A 10va IP65 Outdoors Split Core CT Current Transformer

Model NO.
LZCK-55
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Accuracy
0.5%, 0.5s, 1%
Standards
GB1208-2006;IEC 60044-1;Ntc 2205
Safety Factor Rating
< 10
Rated Frequency
50Hz or 60Hz
Environment
Outdoors or Indoors
Rated Secondary Current
5A or 1A
Secondary Winding Power Frequency Withst
3kv/1min
Types
Split Core Current Transformer
Ratio
100-1500A/5A
Output Signal
10m Cable
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
0.5% or 1%
Origin
Beijing, China
HS Code
8504311000
Model NO.
LZCK-55
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Accuracy
0.5%, 0.5s, 1%
Standards
GB1208-2006;IEC 60044-1;Ntc 2205
Safety Factor Rating
< 10
Rated Frequency
50Hz or 60Hz
Environment
Outdoors or Indoors
Rated Secondary Current
5A or 1A
Secondary Winding Power Frequency Withst
3kv/1min
Types
Split Core Current Transformer
Ratio
100-1500A/5A
Output Signal
10m Cable
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
0.5% or 1%
Origin
Beijing, China
HS Code
8504311000
LZCK-55 400/5A 10VA IP65 Outdoors Split Core ct Current Transformer for 10KV power line
400/5A 10va IP65 Outdoors Split Core CT Current Transformer

400/5A 10va IP65 Outdoors Split Core CT Current Transformer
400/5A 10va IP65 Outdoors Split Core CT Current Transformer
LZCK series IP65 outdoors instrument split core current transformers applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV, and microcomputer protection. This type of current transformer employs imported silican steel which with high permeability as magnetic material, have the characteristics of Small magnetic circuit loss and can be cut, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1500A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters 
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2
Working conditions 
Operating temperature-35°C to +65°C, average  not exceeding +40°C
Storage temperature-40°C to +70°C
Ingress ProtectionIP65
Environmentoutdoors or indoors
The Height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

Selection Type
TypeLZCK-55(2.5m cable)
PurposeMeasuring current transformer
RatioAccuracy class and rated load(VA)
I1/I20.5S0.513
100/5  1.52.5
150/5  1.52.5
200/52.52.52.53
250/52.52.52.53
300/52.52.52.55
400/55555
500/55555
600/55555
750/55555
800/5551010
1000/510101010
1200/510101010
1250/510101010
1500/510101020