China Outdoor Three Phase Step Down Ground Mounted GM Distribution Transformer, Find details about China Toroidal, 33kv Distribution from Outdoor Three Phase Step Down Ground Mounted GM Distribution Transformer
1.Power Capacity: 25-20000KVA
2.Voltage Level: 10KV,11KV, 13.8KV,15KV,17.5KV ,20KV,22KV ,24KV ,30KV,33KV 35KV 36KV and Others as customers requirement
3.Type of Voltage Regulation: Off-circuit or On-Ioad
4.Tapping Range: ±5 % ±2x2.5 % ±4x2.5 %
5.Frequency: 50Hz or 60Hz
6.Phases: Three or single
7.Connection Symbol: Dyn11,Yyn0 ( or as requested)
8.Short- circuit Impedance: Standard Impedance
9.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.
TECHNICAL SPECIFICATION FOR TRANSFORMERS | ||||
NO. | Description | Unit | Guaranteed Value | |
1 | Country of Origin | CHINA | ||
2 | Standard | IEC60076 | ||
3 | Type | Oil immersed type | ||
4 | Brand | Yawei | ||
5 | Installation | Outdoor | ||
6 | Max. ambient temperature | -30ºC~40ºC | ||
7 | Altitude | ≤1000m | ||
8 | Rated Power | kVA | 600 | |
9 | Primary Voltage | kV | 34.50 | |
10 | Secondary Voltage | kV | 3-0.75 | |
11 | Rated Frequency | Hz | 60 | |
13 | Number of winding | 2 | ||
14 | Number of phase | 3 | ||
15 | Tap Range | ±2X2.5% | ||
16 | Refrigerant | Mineral oil (PCB FREE) | ||
17 | Cooling Method | ONAN | ||
18 | No-load losses | w | 1230 | |
19 | Load losses | w | 9900 | |
20 | Impedance | % | 6.50 | |
21 | The temperature rise -Top oil | K | 60 | |
22 | The temperature rise --Winding | K | 65 | |
23 | Basic insulation level(BIL) | |||
a) | Primary | kV | 170 | |
b) | Secondary | kV | 60/0 | |
24 | Power frequency withstand voltage | |||
a) | Primary | kV | 70 | |
b) | Secondary | kV | 20 | |
25 | Vector Group | Dyn11 | ||
26 | Core material | Grain oriented silicon steel | ||
27 | Winding material(HV/LV) | COPPER |
No. | Item | Data |
1 | Aplication | photovoltaic |
2 | Type | insulating mineral oil ,according to standard IEC 60296 |
3 | Cooling method | ONAN |
4 | Installation | Outdoor / Indoor |
5 | Primary nominal voltage | 34.5 KV (available 13.2KV, 13.8KV 15KV ,11KV..) |
6 | Secondary nominal voltage | 800 V |
7 | Frequency | 60 Hz |
8 | connection group | Dyn11 Yn11 (secondary double winding) |
9 | Losses | Reduced |
10 | Max. losses in empty (no load) | BK36B036 |
11 | Max losses in load | BK36B036 |
12 | Tapping changer | ± 2 x 2.5% , manual |
13 | short-circuit impedance | 6% |
14 | class | A |
15 | Corrosion | C 4 |
16 | Electrostatic screen between MT/BT | Yes, connect to ground |
17 | DV/DT | 500V /us |
18 | MT side connection | by angled plug-in terminals |
19 | BT side connection | through terminals on copper plate |
20 | Connection protections MT side | metal drawer cover for outdoor IP55 (Optional) |
21 | Connection protections BT side | IP55 metal outdoor cover drawer with cable glands for BT cable entry (optional) |
22 | Cuba oil collection and filter | optional |
23 | wheels | yes |
24 | lifting lugs | yes |
25 | filling arrangement oil and drainage | yes |
26 | communication and control | DGPT2 digital output signals |
27 | product warranty | ≥ 2 years |
"Jiangxi Yawei Electrical Co.,Ltd." is engaged in manufacturing,development,service ,solution,maintenance & marketing of H.V./L.V. power distribution equipments,switchgears,transformers,substations..etc .for all over the world. As a leading & professional manufacturer in China,we mainly manufacture below items and supply their electrical accessories:
· H.V.& L.V.switchgears
· Power Distribution Board (PDB)
· M.V solid insulated switchgears (SIS)
· compact substations /Package substation/kiosk substation
· single phase & three phase pad mounted transformers(PMT)
· Gas insulated switchgears(GIS)
· Cable Brach box
· Ring main units (RMU)
· Oil-immersed transformers and dry type transformers
· Vacuum circuit breakers (VCB),Air circuit breakers(ACB),vacuum switch and contactors.