Middle Esp Duct Air Conditioner with Various Air Supply Types

China Middle Esp Duct Air Conditioner with Various Air Supply Types, Find details about China Inverter Air Conditioner, Commercial Air Conditioner from Middle Esp Duct Air Conditioner with Various Air Supply Types

Model NO.
BLA-24D (24K)
Condition
New
Material
Galvanized Steel Powder Coated
Service
OEM
Controller
Remote Controller
Control
WiFi/RS485
Cooling Capacity
24K
Design
Split
Trademark
Blueway
Transport Package
Carton Packing for Container Order
Origin
Guangdong, China
HS Code
8415102210
Model NO.
BLA-24D (24K)
Condition
New
Material
Galvanized Steel Powder Coated
Service
OEM
Controller
Remote Controller
Control
WiFi/RS485
Cooling Capacity
24K
Design
Split
Trademark
Blueway
Transport Package
Carton Packing for Container Order
Origin
Guangdong, China
HS Code
8415102210

PRODUCTION DESCRIPTION


Duct Air Conditioning systems are designed to perform well in any kind of weather, providing you with convenient comfort throughout all four seasons. With R410a eco-friendly refrigerant, optional on-off and inverter type, customized order is acceptable due to outsatnding R&D capacity from Blueway Company.
 

KEY FEATURES

Super Slim Body


Super sim body(height 200mm), Minimum depth only 450mm, smaller than other suppliers, saving much installation space.

Middle Esp Duct Air Conditioner with Various Air Supply Types
 
Middle Esp Duct Air Conditioner with Various Air Supply Types

Built-in drain pump


Cassette with built-in drain pump, can lift water up to 750mm, convinient for installation and improving drainage efficiency.

 

UItra Low Noise


Indoor units run stable and reliable with high efficiency fan motor, and noise down to 23dB.

Middle Esp Duct Air Conditioner with Various Air Supply Types
 
Middle Esp Duct Air Conditioner with Various Air Supply Types

High-grade Exquisite Arc Panel (optional)


Double air guide panel design, remote control receiving head hidden under the panel, function area delicate digital display, and interior decoration integration, enjoy comfor-table, highlight taste.

Wide ESP Range

The Maximum air supply ESP up to 30Pa can connect longer duct tube. supply strong cooling or heating wind and fasten air cycle.

 

Personalized Return Air Way


Standard built air return box, easy to adjust the back air return or down air return based installation requirment.

Middle Esp Duct Air Conditioner with Various Air Supply Types
 

TECHNICAL SPECIFICATIONS

Options: R410a Split Duct Air Conditioner (Inverter & On-Off, Normal & Low Ambient Type)

Specifications of Inverter Universal Outdoor Unit (R410A Cooling & Heating)
Outdoor UnitModelBLA-18HA/DVOBLA-24HA/DVOBLA-36HA/DVOBLA-48HA/DVOBLA-60HA/DV3O
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.050 10.550 14.000 16.000 
Heating CapacityBtu/h1980026400396005280060500
kW5.800 7.750 11.600 15.500 17.600 
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph380-415V~/50Hz/3Ph380-415V~/50Hz/3Ph
Air Flow Volumem³/h26003500490063006300
Noise LeveldB(A)5558596060
Outdoor DimensionUnit(W×H×D)mm780×605×290930×700×3301015×810×445940×1360×440940×1360×440
Packing(W×H×D)mm863×653×412980×760×3801065×865×4851030×1480×4501030×1480×450
Outdoor WeightNetkg33527298108
Grosskg365777108117
Piping SizeLiquid Pipe Sizemmφ6.35φ9.52φ9.52φ9.52φ9.52
Gas Pipe Sizemmφ12.7φ15.88φ15.88φ15.88φ15.88
Max.Pipe Lengthm3535505050
Max.Height Differencem2525303030
Operating RangeCoolingºC21~4321~4321~4321~4321~43
HeatingºC-7~24-7~24-7~24-7~24-7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of Inverter Duct Air Conditioner (R410A Cooling & Heating)
Indoor UnitModelBLA-18D2HRA/DVIBLA-24D2HRA/DVIBLA-36D2HRA/DVIBLA-48D2HRA/DV3IBLA-60D2HRA/DV3I
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.050 10.550 14.000 16.000 
Heating CapacityBtu/h2000026500400005000060500
kW5.80 7.90 11.70 14.650 17.731
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph
Power Input(W)Cooling16352180305041805420
Heating18102350322444405460
PerformanceEERW/W3.323.223.463.353.23
COPW/W3.43 3.343.633.50 3.37
Air Flow Volumem³/h1100/900/7001300/1100/9001650/1450/10502000/1700/12502200/1800/1600
External Static PressurePa405080100100
Indoor DimensionNoise Level  (dB(A))Hi/Med/Low43/40/3646/41/3747/44/4049/47/4451/49/46
Unit(W×H×D)mm1010×210×4701190×250×6401425×250×6401425×250×6401425×250×640
Indoor WeightPacking(W×H×D)mm1110×240×5101255×315×7201490×315×7201490×315×7201490×315×720
Netkg2326354545
Grosskg2830405252
Piping SizeLiquidmmφ6.35φ9.52φ9.52φ9.52φ9.52
Gasmmφ12.7φ15.88φ15.88φ15.88φ15.88
DrainagemmOD25OD25OD25OD25OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Universal Outdoor Unit - Normal Ambient Type (R410A Cooling & Heating)
Outdoor UnitModelBLC-18HRA/UOBLC-24HRA/UOBLC-36HRA/UOBLC-48HRA/U3OBLA-60HRA/U3O
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.050 10.550 14.000 16.000 
Heating CapacityBtu/h2000026500400005000060500
kW5.900 7.900 12.000 14.650 17.731
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph380-415V~/50Hz/3Ph380-415V~/50Hz/3Ph380-415V~/50Hz/3Ph
Air Flow Volumem³/h21003500490063006300
Noise LeveldB(A)4954586057
Outdoor DimensionUnit(W×H×D)mm780×605×290930×700×3301015×810×445940×1360×440940×1360×440
Packing(W×H×D)mm863×653×412980×760×3801065×865×4851030×1480×4501030×1480×450
Outdoor WeightNetkg38517298108
Grosskg425477108117
Piping SizeLiquid Pipe Sizemmφ6.35φ9.52φ9.52φ9.52φ9.52
Gas Pipe Sizemmφ12.7φ15.88φ15.88φ15.88φ15.88
Max.Pipe Lengthm2530305050
Max.Height Differencem1515203030
Operating RangeCoolingºC21~4321~4321~4321~4321~43
HeatingºC-7~24-7~24-7~24-7~24-7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating)
Indoor UnitModelBLC-18D2HRA/UIBLC-24D2HRA/UIBLC-36D2HRA/UIBLC-48D2HRA/UIBLC-60D2HRA/UI
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.200 10.550 14.000 16.119 
Heating CapacityBtu/h2000026500400005000060500
kW5.900 7.900 12.000 14.650 17.731
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph
Power Input(W)Cooling17612351358445605694
Heating15132388346844464845
PerformanceEERW/W3.013.062.943.072.83
COPW/W3.90 3.313.463.30 3.66
Air Flow Volumem³/h1170/770/6501400/950/8001800/1500/13502100/1750/15502200/1800/1600
External Static PressurePa707080100100
Indoor DimensionNoise Level  (dB(A))Hi/Med/Low43/35/3246/43/4146/44/4247/44/4247/45/43
Unit(W×H×D)mm1010×210×4701190×250×6401425×250×6401425×250×6401425×250×640
Indoor WeightPacking(W×H×D)mm1110×240×5101255×315×7201490×315×7201490×315×7201490×315×720
Netkg2326354545
Grosskg2830405252
Piping SizeLiquidmmφ6.35φ9.52φ9.52φ9.52φ9.52
Gasmmφ12.7φ15.88φ15.88φ15.88φ15.88
DrainagemmOD25OD25OD25OD25OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Universal Outdoor Unit - Low Ambient Type (R410A Cooling & Heating)
Outdoor UnitModelBLC-18CHRA/UO-LBLC-24HRA/UO-LBLC-36HA/U3O-LBLC-48HA/U3O-LBLC-60HA/U3O-L
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.050 10.550 14.000 16.000 
Heating CapacityBtu/h2000026500400005000060500
kW5.900 7.900 12.000 14.650 17.731
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph380-415V~/50Hz/3Ph380-415V~/50Hz/3Ph380-415V~/50Hz/3Ph
Air Flow Volumem³/h21003500490063006300
Noise LeveldB(A)4954586057
Outdoor DimensionUnit(W×H×D)mm780×605×290930×700×3301015×810×445940×1360×440940×1360×440
Packing(W×H×D)mm863×653×412980×760×3801065×865×4851030×1480×4501030×1480×450
Outdoor WeightNetkg38517298108
Grosskg425477108117
Piping SizeLiquid Pipe Sizemmφ6.35φ9.52φ9.52φ9.52φ9.52
Gas Pipe Sizemmφ12.7φ15.88φ15.88φ15.88φ15.88
Max.Pipe Lengthm2530305050
Max.Height Differencem1515203030
Operating RangeCoolingºC-15~43-15~43-15~43-15~43-15~43
HeatingºC-7~24-7~24-7~24-7~24-7~24
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 
Specifications of On/Off Duct Air Conditioner (R410A Cooling & Heating)
Indoor UnitModelBLC-18D2HRA/UIBLC-24D2HRA/UIBLC-36D2HRA/UIBLC-48D2HRA/U3IBLC-60D2HRA/U3I
CapacityCooling CapacityBtu/h1800024000360004800055000
kW5.300 7.200 10.550 14.000 16.119 
Heating CapacityBtu/h2000026500400005000060500
kW5.900 7.900 12.000 14.650 17.731
Electrical PartsPower SupplyV/Hz/Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph220-240V~/50Hz/1Ph
Power Input(W)Cooling17612351358445605694
Heating15132388346844464845
PerformanceEERW/W3.013.062.943.072.83
COPW/W3.90 3.313.463.30 3.66
Air Flow Volumem³/h1170/770/6501400/950/8001800/1500/13502100/1750/15502200/1800/1600
External Static PressurePa707080100100
Indoor DimensionNoise Level  (dB(A))Hi/Med/Low43/35/3246/43/4146/44/4247/44/4247/45/43
Unit(W×H×D)mm1010×210×4701190×250×6401425×250×6401425×250×6401425×250×640
Indoor WeightPacking(W×H×D)mm1110×240×5101255×315×7201490×315×7201490×315×7201490×315×720
Netkg2326354545
Grosskg2830405252
Piping SizeLiquidmmφ6.35φ9.52φ9.52φ9.52φ9.52
Gasmmφ12.7φ15.88φ15.88φ15.88φ15.88
DrainagemmOD25OD25OD25OD25OD25
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
 

MANUFACTURING & SHIPMENT

 

Middle Esp Duct Air Conditioner with Various Air Supply Types

 

ADVANTAGES & MARKET OVERVIEW

 

1.Blueway has around 30 years of rich HVAC manufacturing experience.

2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.

3.Over 10000 engineering solutions with great success provided by Blueway.

4.Online technical service is available twenty-four hours a day without break.

5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
 

With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.

 

So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
 

Middle Esp Duct Air Conditioner with Various Air Supply Types

 

FAQ

Q: Recommended places of use?

A: Superthin Low ESP Duct type for living room, dining room, bedroom, hotel room, etc. Middle ESP Duct type for shops, lobbies, offices, clubs, etc.

 

Q: Whether with drain water pump?

A: Yes, cassette with built-in drain pump, which can lift water up, convenient for installation and improving drainage efficiency.

 

Q: What's the hot selling range?

A: 30K & 48K On-Off and inverter Duct Split Air Conditioning.

 

Q: Adopt which refrigerant type?

A: R410a.

 

Q: With remote controller?

A: It depends on the customers, wired or remote controller, WIFI control are for options.

 

Q: Hong long is the warranty time?

A: 1 year for the whole unit, 3 years for the compressor.

 

Q: Can be customized?

A: Yes, we can provide customized product based on the actual condition of the engineering site.