40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer

China 40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer, Find details about China Sectionalizer, Sf6 Load Break Switch Sectionalizer from 40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer

Model NO.
RPS
HS Code
8535210000
Model NO.
RPS
HS Code
8535210000
KEMA TEST REPORT
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer

Summary


Pole-mounted load break switch(pole-LBS) applies up to 36KV 400/630A, 50Hz pole-LBS associated with a state of the art controller. This SF6 gas-insulated switch can corporate with the distribution automation system, and also isolate a faulted section of distribution line from the control center.

A simple pole-mounting arrangement contribute to quick and low cost installation, and the switch can be operated manually with a electronic controller. Electronic controller is contained in a stainless steel cabinet for an all weather environmental conditions. Remote monitoring and control can also be provided mounting wire or wireless modem in a cabinet.

Standard service condition

It shall be principal that this SF6 Gas Load Break Switch shall be used in the following service condition:
Ambient temperature
Short period peak value:50ºC
Average over a period of 24 hours: 40ºC
Lower limit over 24 hours: -25ºC
Relative humidity: 100%
Maximum altitude:1,000 meter

Features

 
  1. rugged switch
  2. drivepipe with large diversity
  3. quick operation
  4. inflation valve
  5. high pressure relief alarm
  6. HD gas-pressure meter
  7. Manual locking device
  8. Low pressure warning device
  9. Visible open/close status
  10. Cintact position indicator
  11. Manual operation on ground
  12. To provide one-stop service, please consult!
 
Product mode RPS-15RPS-24RPS-38
Rated voltageKV152438
6/12/17.525.836
Rated frequencyHz50/6050/6050/60
Lightning impulse withstand voltageKV110125200
Power frequency withstand voltage 1minDryKV5075110
wet406095
Rated currentA400/630
Peak withstand currentKA505050
Rated short time making currentKA202020
Rated short time withstand currentKA/S20/420/420/4
Rated cable charging breaking currentA101620
Rated line charging breaking currentA11.52
Rated closed-loop breaking currentA400/630
Rated current breaking timesTimes≥400
Rated working pressureMpa0.05
Per-phase main circuit resistance≤80
Relative gas leakage rateYear≤1%
Operation of mechanical stabilityTimes6000
weightkg115125135
Institutions boxes and controller protection classIP67
Type of mountingThe lifting type(suspended)/block(horizontal)
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer
40.5kv Outdoor Lbs Pole Mounted Sf6 Load Break Switch Sectionalizer