SCR Series SCR DC Power Supply

China SCR Series SCR DC Power Supply, Find details about China DC Power Supply, SCR Rectifying Power Supply from SCR Series SCR DC Power Supply

Model NO.
SRP
Iron Core Shape
EI
Power Source
Linear Regulated Power Supply
Application Range
Industrial and Mining Enterprises
Brand
Idealtek
Output Voltage
0~800V (Max.)
Output Current
0~20000A (Max.)
Circuit Mode
AC/DC Power Frequency Transformation
Working Mode
Constant Voltage / Constant Current
Output Setting
10-Turn Potentiometer
Output Display
LED or LCD
Protection
Ov, Oc, Oh, Lack Phase
Remote Control
0~10V / 4~20mA Analog Signal Control
Cooling Method
Forced-Air Cooling
Application
Water Treatment, Heating
Trademark
IdealTek
Transport Package
Plywood Case
Specification
transformer, inductance, control circuit
Origin
China
HS Code
85044019
Model NO.
SRP
Iron Core Shape
EI
Power Source
Linear Regulated Power Supply
Application Range
Industrial and Mining Enterprises
Brand
Idealtek
Output Voltage
0~800V (Max.)
Output Current
0~20000A (Max.)
Circuit Mode
AC/DC Power Frequency Transformation
Working Mode
Constant Voltage / Constant Current
Output Setting
10-Turn Potentiometer
Output Display
LED or LCD
Protection
Ov, Oc, Oh, Lack Phase
Remote Control
0~10V / 4~20mA Analog Signal Control
Cooling Method
Forced-Air Cooling
Application
Water Treatment, Heating
Trademark
IdealTek
Transport Package
Plywood Case
Specification
transformer, inductance, control circuit
Origin
China
HS Code
85044019
SCR Series SCR Controlled DC Power Supply

SCR Series SCR DC Power Supply
 
Electrical Characteristics
1. Input,OutputInput: Three-phase380Vac±10% 50Hz/60Hz±10%
Output: DC C.C. and/or C.V.
Max output: as requirements
2. Accuracy (C.V.)Line regulation: ≤0.1% Of the rated value (output voltage change ratio under input ±10% change)
Stability: during 8 hrs≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working)
Temp. coeff.offset: ≤0.04% of the rated value/ºC(output voltage change ratio due to environment temperature changes)
Load regulation(load 0~100%): ≤1% of the rated value (output voltage change ratio due to output current change from 0 to rated value)
3. Accuracy (C.C.)Line regulation(361-418V): ≤0.1% Of the rated value (output current change ratio under input ±10% change)
Stability: during 8 hrs≤0.3% of the rated value(output current change ratio due to 8 hours continuously working)
Temp. coeff.offset: ≤0.04% of the rated value/ºC(output current change ratio due to environment temperature changes)
Load regulation(load 0~100%): ≤1% of the rated value (output current change ratio due to output voltage change from 0 to rated value)
4. Ripple + Noise (r.m.s)C.V: ≤1% of the rated value+10mV (Rated output power)
5. Ripple +Noise (p-p)C.V: ≤5% of the rated value+10mV (Rated output power)
5. Programming output voltageAdjustable (0~rated value) or CV
6. Programming output currentAdjustable (0~rated value) or CC
7. Adjusting mode10-turn Potentiometer
Key button (optional)
9. Protections functionOutput auto-protection and alarm when over voltage / over current / lack phase / over temp.
10. Short protectionWithstand transient short-circuit.
11. Working modeWithstand long-term continual working at full load
12. Read outputDigital LED
LCD (optional)
13. Display precisionDepends on output specification
14. Display accuracy≤±1%±1digit (range:5%~50% of the rated value)
≤±0.5%±1digit (range:50%~100% of the rated value)
15. Load characteristicOn demand
16. Operating conditionLocation: indoor use only.
Temperature:-20°C ~ +40°C
Humidity:≤80%
17. Spare partsCompany standard (fuse, main board, operation CD and other wearing parts)
 
Input Voltage: Power source voltage can be changed to others on request. 
Custom-made specifications are on request.




Products Gallery

SCR Series SCR DC Power SupplySCR Series SCR DC Power SupplySCR Series SCR DC Power SupplySCR Series SCR DC Power SupplySCR Series SCR DC Power Supply

Storage


Pay attention to the following points during temporary & long-term storage.
1. Store the power supply in our packing box
2. Long-term storage would lead to electrolytic capacitor degradation, it should be powered up yearly, at least 5 hours power-on time, input voltage should be increased to rated value by voltage regulator.  



Warranty

1. The warranty period of this product is 12 months, free repair within warranty period except for man‐made damages or irresistible forces.
The following cases during under warranty are not included in free-warranty scope:
(1). Incorrect operation & maintenance of the power source that cause fault.
(2). Natural loss of consumable material (shell, connector etc.)
(3). Manual damage caused by modification or dismantle
(4). Damage caused by external equipments or third-party product or plug-in units.
(5). Force majeure factors, such as fire, flood or input grid abnormal.
(6). Unilateral amendment or modification on our LOGO or part number.
(7). Fault caused by abnormal usage of power source.
(8). Other non-product quality causes
2. Reasonable maintenance & repair costs should be charged after warranty period.