Model NO.
Techsem Thyristor
Encapsulation Structure
Ceramic Packaged Transistor
Power Level
Medium Power
Material
Silicon Transistor
Furnace Spares Package
Paper Box or Wood Box
Spare Parts Delivery Way
Fast Courier
Type
Diode
Function and Usage
Switch Transistor
Operating Frequency
High Frequency Transistor
Current Capacity
Medium Power Transistor
Shielding Way
Sharp Cutoff Shielding Tube
Craft
Planar Transistor
Trademark
HIKING
Transport Package
Paper Box or Plywood Box
Specification
All models for 100kg to 10 tons induction furnace
Origin
Weifang, China
HS Code
85143000
Model NO.
Techsem Thyristor
Encapsulation Structure
Ceramic Packaged Transistor
Power Level
Medium Power
Material
Silicon Transistor
Furnace Spares Package
Paper Box or Wood Box
Spare Parts Delivery Way
Fast Courier
Type
Diode
Function and Usage
Switch Transistor
Operating Frequency
High Frequency Transistor
Current Capacity
Medium Power Transistor
Shielding Way
Sharp Cutoff Shielding Tube
Craft
Planar Transistor
Trademark
HIKING
Transport Package
Paper Box or Plywood Box
Specification
All models for 100kg to 10 tons induction furnace
Origin
Weifang, China
HS Code
85143000
1. Product Name:Thyristor, SCR, Induction furnace spare parts
Induction furnace spare parts, melting furnace spares, main board, MPU-6FK, thyristor, SCR, resistor, capacitor, reactor coil, furnace pot, induction coil, pulse transformer, meters, temperature tester, heat exchanger, water cooler
Techsem Thyristor Used for Induction Furnace in China
Techsem Thyristor Used for Induction Furnace in China
Techsem Thyristor Used for Induction Furnace in China

2. Model: For Induction Melting Furnace,Induction Heating, Induction Hardening, Induction Quenching furnace


Phase Control Thyristors
FeaturesTypical Applications
1.Amplifying gates        
2.International standard cases  
3.Hermetic metal cases with ceramic 
  insulators 
4.Capsule packages for double sided 
  cooling
1.High power industrial and power 
  transmission
2.DC and AC motor control
3.Controlled rectifiers
4.Soft starters for induction motors
5.AC controllers

 
 
 
TypeVDRM/VRRMIT(AV)ITSMIGTVGTVTM/ITMVTOrTRth(j-c)Rth(c-hs)TjmMounting
Force
Outline
 TC55°CTC70°C10 ms25 °C125 °C     
 VAKAmAVV/AV°C/W°C/W°CKN 
Y24KPA200-600660550830-2000.8-2.01.11/10000.750.360.0800.0201253.3-5.5outline
Y30KPA200-60010108601235-2500.8-2.51.23/15000.730.330.0450.0101255.3-10outline
Y38KPA200-600155013001835-3000.8-2.51.04/20000.760.140.0350.00812510-20outline
Y50KPA200-600245021503240-3000.8-3.01.05/30000.750.100.0200.00512519-26outline
Y24KPC400-1000530450530-2000.8-2.01.29/7700.750.700.0800.0201253.3-5.5outline
Y30KPC400-10001000850935-2500.8-2.51.24/15500.700.350.0450.0101255.3-10outline
Y35KPC400-100010809201135-2500.8-2.51.40/15000.80.400.0350.00812510-20outline
Y38KPC400-100011309601335-3000.8-2.51.43/18000.800.350.0350.00812510-20outline
Y40KPC400-1000135011501535-3000.8-2.51.57/24000.850.300.0280.007512515-20outline
Y45KPC400-1000158013402040-3000.8-3.01.63/30000.880.250.0240.00612518-25outline
Y50KPC400-1000225019003040-3000.8-3.01.25/25500.890.120.0200.00512519-26outline
Y60KPC400-1000256021603340-3000.8-3.01.43/40000.950.120.0160.00412521-30outline
Y70KPC400-1000375031703840-3000.8-3.01.22/50000.820.080.0120.003512530-40outline
Y76KPC400-1000437037006040-3000.8-3.01.20/50000.850.070.0100.00312535-47outline
Y89KPC400-1000577049006640-3000.8-3.01.18/50000.880.060.0070.00212563-84outline
Y100KPC400-1000750064007440-3000.8-3.01.18/60000.850.0550.0050.001512581-108outline
Y24KPE1100-18004203604.6530-2000.8-2.02.10/6000.851.200.0800.0201253.3-5.5outline
Y30KPE1100-18006906007.535-2500.8-2.52.11/15500.880.800.0400.0101255.3-10outline
Y38KPE1100-180010408901135-3000.8-2.51.43/17000.850.420.0350.00812510-20outline
Y40KPE1100-1800126010701240-3000.8-3.01.75/24000.910.350.0280.007512515-20outline
Y45KPE1100-1800147012501340-3000.8-3.01.80/30000.930.290.0240.00612518-25outline
Y50KPE1100-1800180015402440-3000.8-3.01.42/25500.910.230.0200.00512519-26outline
Y55KPE1100-1800208017602640-3000.8-3.01.49/30000.950.180.0180.00412521-30outline
Y60KPE1100-1800236020003040-3000.8-3.01.58/40000.980.150.0160.00412521-30outline
Y65KPE1100-1800289024603540-3000.8-3.01.32/32200.870.140.0130.003512527-34outline
Y70KPE1100-1800311026703840-3000.8-3.01.50/50000.800.140.0120.00312530-40outline
Y76KPE1100-1800404034405140-3000.8-3.01.29/50000.840.090.0100.00312535-47outline
Y40KPH1900-30008707501040-30000.8-3.02.37/15001.200.780.0280.007512515-20outline
Y50KPH1900-3000146012402040-3000.8-3.02.02/25501.110.360.0200.00512519-26outline
Y55KPH1900-3000168014301840-3000.8-3.01.78/30000.970.270.0180.00412521-30outline
Y60KPH1900-30001950166023.640-30000.8-3.01.83/30000.980.210.0160.00412521-30outline
Y70KPH1900-3000244020702840-3000.8-3.01.83/40001.070.190.0120.003512530-40outline
Y76KPH1900-3000296025303240-3000.8-3.01.60/30001.050.180.0100.00312535-47outline
Y89KPH1900-3000452038604440-3000.8-3.01.54/50000.990.110.0070.00212563-84outline
Y100KPH1900-3000616052906540-4500.9-3.51.45/60000.910.090.0050.001512581-108outline
Y38KPJ3100-4200590510735-3000.8-2.52.83/11001.181.500.0350.00812510-20outline
Y50KPJ3100-4200122010501340-3000.8-3.02.18/18301.140.570.0200.00512519-26outline
Y65KPJ3100-4200191016402040-3000.8-3.02.30/32201.170.350.0130.003512527-34outline
Y76KPJ3100-4200246021102740-3000.8-3.01.99/30001.150.280.0100.00312535-47outline
Y89KPJ3100-4200375032304040-3000.8-3.01.90/50001.00.180.0070.00212563-84outline
Y100KPJ3100-4200556047906050-3000.9-3.51.48/50000.880.120.0050.001512581-108outline
Y38KPM4300-52006205304.535-3000.8-3.02.83/12001.451.150.0350.00812510-20outline
Y50KPM4300-520010709301040-3000.8-3.02.98/18301.040.840.0200.00512519-26outline
Y65KPM4300-5200154013301740-3000.8-3.02.46/20001.300.580.0130.003512524-34outline
Y76KPM4300-5200219018802440-3000.8-3.02.35/30001.300.350.0100.00312535-47outline
Y89KPM4300-5200329028403440-3000.8-3.01.81/30001.090.240.0070.00212563-84outline
Y100KPM4300-5200453036504540-3000.8-3.01.64/30001.130.210.0050.001512581-108outline
H38KPN4500-55004704004.540-3000.8-3.02.80/10001.081.920.0450.00812510-20outline
H38KPN4500-55005504404.540-3000.8-3.02.80/10001.081.920.0350.00812510-20outline
H50KPN4500-550010108501240-3000.8-3.01.90/10001.070.830.0220.00512519-26outline
H50KPN4500-550010709201240-3000.8-3.01.90/10001.070.830.0200.00512519-26outline
H76KPN4500-5500217018002240-3000.8-3.02.20/30001.010.360.0110.00312535-47outline
H76KPN4500-5500230019202240-3000.8-3.02.20/30001.010.360.0100.00312535-47outline
H89KPN4500-5500282023003240-3000.8-3.01.70/30001.030.250.0090.00212563-84outline
H100KPN4500-5500399035004540-3000.8-3.01.54/30001.020.210.00570.001512581-108outline
H125KPN4500-5500580050107240-3000.8-3.01.50/30001.020.140.0040.001125110-140outline
H38KPR5600-65004303504.540-3000.8-3.03.50/10001.252.200.0450.00812510-20outline
H38KPR5600-65005004204.540-3000.8-3.03.50/10001.252.200.0350.00812510-20outline
H50KPR5600-650090072011.840-3000.8-3.02.40/10001.251.030.0220.00512519-26outline
H50KPR560-650095083011.840-3000.8-3.02.40/10001.251.030.0200.00512519-26outline
H65KPR5600-6500139010001840-3000.8-3.02.35/15001.210.700.0140.003512527-34outline
H65KPR5600-6500145011501840-3000.8-3.02.35/15001210.700.0130.003512527-34outline
H76KPR5600-6500168013702240-3000.8-3.02.12/15001.200.6280.0110.00312535-47outline
H76KPR5600-6500177015002240-3000.8-3.02.12/15001.200.6280.0100.00312535-47outline
H89KPR5600-6500222018003240-3000.8-3.01.90/16001.220.420.0090.00212563-84outline
H100KPR5600-6500353028004540-3000.8-3.02.0/30001.140.270.00570.001512581-108outline
H125KPR5600-6500524042007140-3000.8-3.01.73/30001.150.170.0040.001125110-140outline
H38KPS6600-72003803204.040-3000.8-3.02.90/5001.133.100.0450.00812510-20outline
H50KPS6600-72008106506.440-3000.8-3.02.90/10001.281.320.0220.00512519-26outline
3. Usage: Used for GW Induction furnace
Techsem Thyristor Used for Induction Furnace in China

4. Spare parts list photo:
 
Techsem Thyristor Used for Induction Furnace in China

6. Package: Plastic film protection and paper box or wood box.
 

 
7. Delivery: By fast courier, EMS, TNT, DHL, ARAMEX, OR BY SEA