China BVVB Cable Used for Electircal, Find details about China BVVB, BVVB Cable from BVVB Cable Used for Electircal
Applications
1.5mm twin and earth cable for ring main and sockets. Maximum current 27 amp. Solid, Plain annealed Copper. BASEC approved, conforms
with BS6004. New harmonised core identification. PVC insulation. Brown = Live - Blue = Neutral - Earth = Bare Wire
Product Details
Brand | ShanHua |
Standard | G8/T5023-2008 JB8734-1998 |
Nominal Cross Area: Nominal Cross Area | 3*0.75 mm² |
Conductor Material | 99.9% oxygen free copper |
Insulation Material | Eco-friendly PVC |
Insulation Thickness | 0.8mm |
Standard Length | 100M ( ±0.5M ) |
Rated Voltage | 450V / 750V |
MAX OD | 4.9mm |
Approx Weight | 63KG/KM |
Main Colors | Red, Yellow,Green,Blue, Bi-Colors(yellow and green) |
Applications | Laundry machine, plug-in water heater, refrigerator, floor air conditioner |
Used In | Indoors / outdoor household dection, engineering construction projects |
Product Selection Guide
Item Name | Soft or Hard | Cable Core No | Oxidation | Stability | Working Life | Insulation | Sheath |
BV | Solid Wire | Single Core | Hard to be oxidized | Excellent | 50 years if no human damage | Yes | No |
BVR | Flexible Cable | Multi Cores | Hard to be oxidized | Excellent | 50 years if no human damage | Yes | No |
BVVB | Double-Lines Cable | 2 or more cores(separate single wire) | hard to be oxidized | Excellent | 50 years if no human damage | Yes | Yes |
RVV | Double-Lines Cable | 2 or more cores(separate single wire) | hard to be oxidized | Excellent | 50 years if no human damage | Yes | Yes |
BV Solid Cable BVR Flexible Cable BVVB Double-lines Cable RVV Double-lines Cable
1. Differences between Flame Retardant and Common Cables
Flame retardant cables used mostly in industrial and mining enterprises and hotels. It`s not burn readily,and it will be out when away from fire.
Acc. to the retardant grades of ZA/ZB/ZC/(ZR),household may choose the ZR/ZC items.
2.
Red cable is for live wire, the Yellow & Green Cables are for earth wire
Green,white,yellow,blue,black are for null wires
3. Voltage
Nominal Cross Area | 220V | 380V | Nominal Cross Area | 220V | 380V |
1.5mm² | 4900 watt | 14000 watt | 10mm² | 12500 watt | 35500 watt |
2.5mm² | 5500 watt | 15500 watt | 16mm² | 16200 watt | 46000 watt |
4mm² | 7200 watt | 20500 watt | 25mm² | 21100 watt | 60000 watt |
6mm² | 9200 watt | 26000 watt | 35mm² | 26400 watt | 75000 watt |
Note: Above voltages are all MAX(maximum), Acc. to specific working environment differences, there is a bit deviation, please keep 20%
Tolerance. It`s just for reference.
4. Cable Consumption Calculation
Note: Specified Quantity Depends on Actual Execution and Construction
Decration Area | 50-70m² | 70-100m² | 100-140m² |
Lightings | 1.5mm², 200m | 1.5mm², 300m | 1.5mm², 400m |
Outlets | 2.5mm², 300m | 2.5mm², 500m | 2.5mm², 600m |
Air condition and water heating | 4mm², 50m | 4mm², 100m | 4mm², 150m |
Centrial air-conditioning | ------ | 6mm², 50m | 6mm², 50m |
House service wire | 6mm², 50m | 6mm², 50m | 6mm², 50m |