China 1200c/1400c/1600c, 10PA Laboratory Vacuum Furnace for University Sintering/Heating Treatment/Experiment/Price List, Vacuum Heat Treatment Furnace/Oven, Find details about China Vacuum Heat Treatment Furnace, Lab Vacuum Furnace from 1200c/1400c/1600c, 10PA Laboratory Vacuum Furnace for University Sintering/Heating Treatment/Experiment/Price List, Vacuum Heat Treatment Furnace/Oven
Introduction for Vacuum Furnace
1200C/1400C/1600C, 10Pa laboratory vacuum furnace for university sintering/heating treatment/experiment/price list,vacuum heat treatment furnace/oven
HIQ high temperature vacuum atmosphere furnaces facilitate operation of firing
cycles where atmosphere condition can be altered during operation cycle, from
oxidizing, (such as air to inert atmosphere), or argon/nitrogen to vacuum. This type
of vacuum furnace makes multi-atmosphere process in one cycle possible: binder
burn out in air and parts sintering under vacuum or inert gas atmosphere. These
atmosphere furnaces are designed for accurate air/inert gas flow rate control,
accurate temperature control, excellent temperature uniformity, long lasting
performance and safe operations. This vacuum atmosphere furnace is ideal for
vacuum atmosphere brazing, sintering, surface treatment, thermal heat treatment
and high temperature material process including stainless steel, titanium, aerospace
material, silicon carbide wafer, other metals and ceramics.
vacuum furnace
1200C/1400C/1600C, 10Pa laboratory vacuum furnace for university sintering/heating treatment/experiment/price list,vacuum heat treatment furnace/oven
Features for Vacuum Furnace
1.Excellent temperature uniformity
vacuum furnace
2.51 Segment Easy Use PID Programmable Temperature Controller, allows
the control of heating rates, dwells (time holds) and cooling rates
vacuum furnace
Technical Parameter for Vacuum Furnace
1200C/1400C/1600C, 10Pa laboratory vacuum furnace for university sintering/heating treatment/experiment/price list,vacuum heat treatment furnace/oven
Model | 1200XV | 1400XV | 1700XV |
Max temperature | 1200C | 1400C | 1700C |
Working temperature | 1100C | 1300C | 1600C |
Heating rate | 0~20C/min | 0~15C/min | 0~15C/min |
Accuracy of temperature control | +/-1C | +/-1C | +/-1C |
Heating elements | Electric resistance wire with molybdenum | SiC rode | MoSi2 rode |
Refractory material | 1430 type alumina ceramic fiber | 1600 type alumina ceramic fiber | 1800 type alumina ceramic fiber |
Furnace structure | Double water cooling system | Double water cooling system | Double water cooling system |
Thermocouple | K | S | B |
Max.Vacuum level(supporting customized products) | 7X10-3 Pa | 7X10-3 Pa | 7X10-3 Pa |
Normal voltage | 110-415V 50/60Hz | 110-415V 50/60Hz | 110-415V 50/60Hz |
Chamber Size | 150x150x150mm (6"x6"x6") 150x150x200mm (6"x6"x8") 200x200x200mm (8"x8"x8") 200x200x300mm (8"x8"x12") 250x250x300mm (10"x10"x12") 300x300x400mm (12"x12"x16") 350x350x400mm (14"x14"x16") 400x400x400mm (16"x16"x16") 500x500x500mm (20"x20"x20") |
Our services
Guarantee:
· One year, We provide permanent technology support.Warranty period appear quality problems free maintenance.After the warranty we need to replace parts we provide at cost price.
· Any technology question, we can provide video instruction, remote video instruction or fly to your country.
· Any problem we will handle in time within 24 hours
Quality
fessional QC team and every steps of processing we will strictly on quality.
· Our products will be conform international standards and has the CE certificate.
Servicing equipment during a breakdown is the worst possible scenario. System failure is unexpected, surprising and always at the wrong time. Alarge is prepared to deal with these situations. In order to raise the service reliability of your equipment, we offer comprehensive support services.
The engineering team at HIQ has the knowledge and experience to manage fleets of heat treating equipment in a planned and professional manner regardless of the equipment manufacturer. The solutions we offer are universal because they are based on best practices for failure prevention in the best sense of the word. Professional Technical Services provided by HIQ is more than the repair in case of failure. We understand how the equipment works and we increase uptime with the help of automated process maintenance that supports equipment architecture and technology solutions including renovation, modernization, and relocation services. Alarge carries out preventive inspections and the subsequent preventive measures using advanced tools in the field of metering and reporting.
You no longer have to worry about downtime and additional costs.
HIQ services are available around the clock, 7 days a week.