China CJBP20 EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 630A 1250A Dead Break Separable Surge Arrester Connectors (Outside Cone Type), Find details about China Cable Termination, GIS Termination from CJBP20 EN50181 11kV 12kV 15kV 24kV 25kV 33kV 35kV 36kV 630A 1250A Dead Break Separable Surge Arrester Connectors (Outside Cone Type)
Test Item | Unit | CJBP20 / CJBKP20 | CJBP20 / CJBKP20 | CJBKP30 | CJBKP30 | CJBKP30 |
YH5WZ-26/66 | YH5W-30/85 | YH5WZ-34/85 | YH5W-36/121 | YH5W-45/118 | ||
Rated voltage ( Ur) | kV | 26 | 30 | 34 | 36 | 45 |
Continuous operating voltage (Uc) | kV | 20.8 | 24 | 27.2 | 28.8 | 36 |
AC reference voltage (U1mA) | kV | U1mA AC≥ 26 | U1mA AC≥ 30 | U1mA AC≥ 34 | U1mA AC≥ 36 | U1mA AC≥ 45 |
DC reference voltage (U1mA) | kV | ≥37 | ≥43 | ≥48 | ≥51.6 | ≥64.5 |
Leakage current under DC 0.75U1mA | μA | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 |
Nominal discharge current | kA | 5 | 5 | 5 | 5 | 5 |
Steep current impulse residual voltage (Peak value) | kV | ≤76 | ≤98 | ≤95 | ≤139 | ≤136 |
8/20μs Lightning impulse residual voltage (Peak value) | kV | ≤66 | ≤85 | ≤85 | ≤121 | ≤118 |
Switching impulse residual voltage (Peak value) | kV | ≤56 | ≤72.2 | ≤75 | ≤103 | ≤100 |
Long-duration current impulse, 2ms | A | 150 | 250 | 150 | 400 | 250 |
4/10μs high current impulse | kA | 65 | 65 | 65 | 65 | 65 |
Partial discharge | - | 21.8kV, ≤10pC | 25.2kV, ≤10pC | 28.6kV, ≤10pC | 30.3kV, ≤10pC | 37.8kV, ≤10pC |
Height (h) | mm | 286 | 318 | 345 | 345 | 420 |
Test Item | Unit | CJBP20, CJBKP20 | CJBP20, CJBKP20 | CJBP20, CJBKP20 | CJBKP30 | CJBKP30 | CJBKP30 |
YH10WZ-26/72 | YH10WZ-30/85 | YH10W-30/91 | YH10WZ-34/95 | YH10W-36/121 | YH10W-45/127.5 | ||
Rated voltage ( Ur) | kV | 26 | 30 | 30kV | 34 | 36 | 45 |
Continuous operating voltage( Uc) | kV | 20.8 | 24 | 24kV | 27.2 | 28.8 | 36 |
AC reference voltage (U1mA) | kV | U1mA AC≥ 26 | U1mA AC≥ 30 | U1mA AC≥ | U1mA AC≥ 34 | U1mA AC≥ 36 | U1mA AC≥ 45 |
DC reference voltage (U1mA) | kV | ≥37 | ≥43 | 43 | ≥48 | ≥51.6 | ≥64.5 |
Leakage current under DC 0.75U1mA | μA | ≤ 50μA | ≤50 | ≤ 20 | ≤50 | ≤50 | ≤50 |
Nominal discharge current | kA | 10 | 10 | 10 | 10 | 10 | 10 |
Steep current impulse residual voltage (Peak value) | kV | ≤ 85 | ≤98 | ≤104 | ≤105 | ≤139 | ≤146.5 |
8/20μs Lightning impulse residual voltage (Peak value) | kV | ≤ 72 | ≤85 | ≤91 | ≤95 | ≤121 | ≤127.5 |
Switching impulse residual voltage (Peak value) | kV | ≤ 65 | ≤64.9 | ≤77 | ≤85 | ≤103 | ≤108.5 |
Long-duration current impulse, 2ms | A | 400 | 400 | 350 | 400 | 400 | 400 |
4/10μs high current impulse | kA | 100 | 100 | 65 | 100 | 100 | 100 |
Partial discharge | - | 21.8kV, ≤10pC | 25.2kV, ≤10pC | 25.2kV, ≤10pC | 28.6kV, ≤10pC | 30.3kV, ≤10pC | 37.8kV, ≤10pC |
Height (h) | mm | 286 | 318 | 318 | 345 | 345 | 450 |