China 3 Phase Online High Frequency 10kVA UPS for Computer Room, Find details about China Online UPS, High Frequency UPS from 3 Phase Online High Frequency 10kVA UPS for Computer Room
ItA19:H51 | Model | XG10KL | XG10K | XG15KL | XG15K | XG20KL | XG20K |
Capacity | VA / Watts | 10KVA / 8KW | 15KVA/12KW | 20KVA/16KW | |||
Input | Normal voltage | 380VAC, 3PH+N+G | |||||
Turn on Voltage range | Phase Voltage(120+-5~274+-5)VAC | ||||||
Frequency range | 40~60Hz+-0.2(adjustable) | ||||||
Input power factor | >0.99(220VAC,full R load) | ||||||
Generator | Support generator input(Generator rating≥2*UPS rating ) | ||||||
line low loss/comeback | Phase voltage (120±5)VAC/(140±5)VAC when Load≤50% | ||||||
Phase voltage (150±5)VAC/(165±5)VAC when 50%< Load≤80% | |||||||
Phase voltage (160±5)VAC/(180±5)VAC when 80%< Load≤90% | |||||||
Phase voltage(175±5)VAC/(190±5)VAC when Load>90% | |||||||
Output | Voltage range | Single phase ,200VAC/208VAC/220VAC/230VAC/240VAC, need confirm before order(Could be adjusted by software,10% derating for 208VAC/200VAC) | |||||
Frequency range | 40~60Hz+-0.2(adjustable) | ||||||
Wave form | Pure Sine Wave | ||||||
Transfer time | 0 ms, Between Line mode and Bat mode | ||||||
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode | |||||||
Voltage distortion | ≤6%,Full RCD load | ||||||
Voltage distortion | ≤2%,Full R load | ||||||
Overload capacity | ≤105%+-5% warning only, 105%+-5%<Load≤125% +-5%1minto bypass ; 125%±5%<load≤150%±5% 30S to bypass,Load>150%±5% 300MS to bypass | ||||||
Load peak ratio | 3:1(max) | ||||||
Battery | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | |||||
Battery voltage | 192VDC or 240VDC | ||||||
Battery capacity | External | External | External | ||||
Recharge time | Depended on battery capacity | Depended on battery capacity | Depended on battery capacity | ||||
Charge Current | Normal 5Amp. Max 7Amp | Normal 5Amp. Max 7Amp | Normal 5Amp. Max 7Amp | ||||
Display | LED Mode | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | |||||
LCD Mode | LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. Fault Code ,LED for line,bat, Inverter, Bypss,Fault | ||||||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | |||||
Overload | Beeping twice every second | ||||||
Fault | Beeping Continuously | ||||||
Bettery low/charger fault | Beeping every 1 second | ||||||
Bypass mode | Beeping every 2 min | ||||||
L/N inverse | Beeping every 2 min | ||||||
Communications | RS-232/USB Interface | With monitoring software | |||||
Working Environment | Surge protection | RJ-45 I/O port available for network or Fax/Modem | |||||
Working temperature | - 20ºC~40ºC | ||||||
Humidity | 0-95% non-condensing | ||||||
Product size | WxDxH (mm) | 533*260*501 | 560*260*717 | 533*260*501 | 560*260*717 | 533*260*501 | 560*260*717 |
Product Weight | Kg | 23 | 73 | 32 | 83 | 33 | 84 |
PCS/CTN | 1 | 1 | 1 | 1 | 1 | 1 | |
CTN size | WxDxH (mm) | 640*360*760 | 705*430*960 | 640*360*760 | 705*430*960 | 640*360*760 | 705*430*960 |
CTN Weight(G/W) | Kg | 26 | 82 | 35 | 92 | 36 | 93 |
REMARK | 3XG*K --- Standard Type Internal battery with Wheel ,3XG*KL---- Long Time Type,External battery, No wheel |