Portable Waterproof Dissolved Oxygen Meter (DO meter)

China Portable Waterproof Dissolved Oxygen Meter (DO meter), Find details about China Dissolved Oxygen Meter, Dissolved Oxygen Tester from Portable Waterproof Dissolved Oxygen Meter (DO meter)

Model NO.
DO-161
Measured Signal
Pulse Peak
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Rang
0 to 199.9%
Battery
2*AAA
Model
Waterproof
Accuracy
±1.5% Fs
Trademark
OEM HP
Transport Package
Carton Box
Specification
25 kgs/bag
Origin
China
HS Code
84219990
Model NO.
DO-161
Measured Signal
Pulse Peak
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Rang
0 to 199.9%
Battery
2*AAA
Model
Waterproof
Accuracy
±1.5% Fs
Trademark
OEM HP
Transport Package
Carton Box
Specification
25 kgs/bag
Origin
China
HS Code
84219990

DO Meter
 
Mode%Mg/LTemperature
Range0 to 199.90~19.990.0-50.0ºC
(32-122ºF)
resolution0.10.010.1ºF (0.1ºC)
Accuracy±1.5% FS±1.5% FS±0.9ºF(±0.5ºC)
Responding Time1min1min1min
CalibrationAt most 2 points
Temperature CompensationAuto (ATC) from 32-122ºF or 0-50ºC
Operating Temperature32-122ºF(0~50ºC) 
Battery2*AAA
ProbePlastic electrode
 
 
DO Calibration  
Calibration
Turn on the meter or return to the Measurement Mode
 
Select % Mode and Immerse the DO probe in the zero-oxygen solution until READY shows.(Get high accuracy ,please immerse the probe for 3min or longer .
The next steps must be performed only when the expectation value will be below 5%.)
 
Press MODE a few times until the Calibrating is flashing on the Second Display, press HOLD/SET to enter Calibration Mode. (Calibrating stop flashing)
 
The meter will automatically recognize the standard solution and automatic calibration. During this process, calibration value will be shown on the Second Display.
 
After Calibration, meter automatically returns to Measurement Mode.
 
100% Calibration
In the Measurement Mode  
 
Turn on the meter or return to the Measurement Mode
 
Select % Mode and Place the probe at 1cm above the liquid until READY shows.(Get high accuracy ,please keep the probe for 1min or longer .)
 
Press MODE a few times until the Calibrating is flashing on the Second Display, press HOLD/SET to enter Calibration Mode. (Calibrating stop flashing)
 
The meter will automatically recognize the standard solution and automatic calibration. During this process, calibration value will be shown on the Second Display.
After Calibration, meter automatically returns to Measurement Mode.
 
At most 2 points calibration: 0% and 100%, when the solution cannot be recognized, show "Err" for 2s. Then automatically returns to Measurement Mode.
NOTE: For 100% calibration, air calibration way is a simple, quick, approximate method.
(For high accuracy, we recommend that users should regularly calibrate. In the following situation, users must recalibrate meters.)
 
Replace probe
l after measuring aggressive chemicals
 
Restore Factory Default   
Press MODE six times, R flash on the Main Display,press HOLD/SET to    
restore factory default and meter will return to Measurement Mode after LCD full-shown for 1S. 
 
AUTO POWER-OFF  
The meter will automatically power off without any operation for 8 min.