Ultraviolet- Visible Spectrophotometer or UV Spectrophotometer

China Ultraviolet-Visible Spectrophotometer or UV Spectrophotometer, Find details about China Visible Spectrophotometer, Spectrophotometer from Ultraviolet-Visible Spectrophotometer or UV Spectrophotometer

Model NO.
752N
Wavelength Accuracy
±2nm
Wavelength Repeatability
1nm
Spectral Bandwidth
4nm
Power
220V 50Hz 300W
Size
440*370*200mm
Weight
17kg
Trademark
TOP
Transport Package
Carton
Specification
ISO9001
Origin
Zhejiang, China (Mainland)
HS Code
9031809090
Model NO.
752N
Wavelength Accuracy
±2nm
Wavelength Repeatability
1nm
Spectral Bandwidth
4nm
Power
220V 50Hz 300W
Size
440*370*200mm
Weight
17kg
Trademark
TOP
Transport Package
Carton
Specification
ISO9001
Origin
Zhejiang, China (Mainland)
HS Code
9031809090
Name: Visible Spectrophotometer

Model: 752N
Ultraviolet-Visible Spectrophotometer or UV SpectrophotometerUltraviolet-Visible Spectrophotometer or UV Spectrophotometer

Introduction

752N visible spectrophotometer using microprocessor control technology, make qualitative, quantitative analysis in the ultraviolet visible spectral region, is the necessary multi-purpose laboratory analysis instruments, and widely used in medical, clinical examination, biochemical, petroleum chemical industry, environmental protection, quality control and tertiary institutions teaching laboratory and other departments

Technical parameter

Wavelength range: 200-1000nm
Wavelength accuracy: ≤ ± 2nm
Wavelength repeatability: ≤ 1nm
Spectral bandwidth: 4nm
Transmission ratio accuracy: ± 0.05%T
Transmission ratio repeatability: ≤ 0.2%T
Transmission ratio range: 0.0-125%T
Absorbance range: -0.097-2.5A
Parasitic light: 0.5%T(at 220nm, 340, 400nm)
Photometric range: 0-1999F
Photometric precision: ± 0.5%T
Power: 220V 50Hz 300W
Size: 440*370*200mm
Weight: 17kg
NameUltraviolet-Visible Spectrophotometer
Model752/752N
Function1uses sparkle diffraction grating monochromator, the wave length precision, monochromatic good, the mixed astigmatism is low and so on.
2 Can the automatic change tungsten halogen lamp and the deuterium lamp.
3Use three No LED digital, T.A.C Read action
4 Has the analog recorder connection, can make the kinetic energy response test.
5The sample room can hold 0.5 - 5cm the ratio color dish.

 
Principle
 
Technical specification1 Wavelength range:200- 800nm
2 Wavelength Accuracy: ±2nm
3 Wavelength Repeat: 0.5nm
4 Transmittance Accuracy: ±0.5
5 Transmittance Repeat: 0.5
6 T-A Change Accuracy: ±0.004A
7 Spectrum band width: 6nm
8 Mixed light: 0.5
9 stability: 0.5 within 3min