30kw 35kw 50kw Silent Yuchai Chinese Diesel Engine Diesel Generator, Find details about China Dg Set, 25 kVA Generator from 30kw 35kw 50kw Silent Yuchai Chinese Diesel Engine Diesel Generator
Genset Main Technical Data | ||||||||||||||||||
Genset Model | MC2DC | |||||||||||||||||
Prime Power | 16kW | |||||||||||||||||
Standby Power | 17.6KW | |||||||||||||||||
Frequency/Speed | 50Hz/1500rpm | |||||||||||||||||
Standard Voltage | 230/400V, Others as Application Requested | |||||||||||||||||
Phases | Three phases, four wires | |||||||||||||||||
Dimensions(L×W×H)mm | Open/Silent dimension as below list | |||||||||||||||||
100% Fuel Cons. (L/H) | 3.9~77.6 | |||||||||||||||||
Base Fuel tank (hour) | 8~10 |
Alternator Specifications | ||||||||||||||||||
Alternator Model | MECCA | |||||||||||||||||
Output power | 16kW-660kW | |||||||||||||||||
Voltage control | AVR | |||||||||||||||||
Number of phase | 3 | |||||||||||||||||
Power factor (Cos Phi) | 0.8 | |||||||||||||||||
Insulation Class | H | |||||||||||||||||
Number of Wires | 6 | |||||||||||||||||
Protection | 23 | |||||||||||||||||
Altitude | ≤ 1000 m | |||||||||||||||||
Number of Pole | 4 | |||||||||||||||||
Exciter type | AREP | |||||||||||||||||
Voltage regulation | ±0.5% | |||||||||||||||||
Totale Harmonic distortion | at no load < 4 % - on load < 4 % | |||||||||||||||||
Bearing | Single | |||||||||||||||||
Coupling | Direct |
Alternator Data | ||||||||||||||||||
♦ Operate either 50Hz or 60Hz. | ♦Stator grease insulation covered | |||||||||||||||||
♦ Standard enclosure IP23, but IP44, IP55 for option | ♦Rotator and excitation high polymer | |||||||||||||||||
♦ Insulation class H. | ♦ Resist the corruption oil and acid | |||||||||||||||||
♦ Shunt excitataion systems. | ♦Rotator balance is in accordance with BS5625 | |||||||||||||||||
♦ AREP or PMG system for options. | standard 12.5 | |||||||||||||||||
♦ Automatic voltage regulator | ♦High-quality lubrication sealed long-time bearing | |||||||||||||||||
♦ Single bearing alternator | ♦Rotator silicon steel close tight |
Standard Accessories | ||||||||||||||||||
*Auto Control Panel | *Starting Motor | |||||||||||||||||
*Main Ciruit Breaker | *Exhaust silencer | |||||||||||||||||
*Fuel tank | *Starting battery | |||||||||||||||||
*Base Frame | *Float battery charger | |||||||||||||||||
*Filter | *Flange |
, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators, with self-owned factory assets, independent R&D team, complete infrastructure equipment, provides a professional solution for the design, production and application support of intelligent generator sets with a broad and diverse range of gen-set power products that can operate independently, paralleled, on-site or remotely controlled.
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm | Low oil pressure alarm | When oil pressure does not reduce normally, the light is on. | -General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm | High water temperature alarm | When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm | Low fuel level alarm | When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm | Battery charger fault alarm | If the charging system has fault, when engine running, the light is off. | -Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm | Crank failure alarm | When the generator set failed three times (or six times) in a row starting, the light is on. | -Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm | Overload or breaker tripping alarm | When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. | -In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |