Agreed thermal current lth | 20 | 40 | 63 | 80 | 100 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 |
Rated insulation voltage Ui | 750V | 1000V | |||||||||||||||
Rated impulse withstand voltage Uimp | 8KV | 12KV | |||||||||||||||
Rated voltage of the switch copper | AC 440V | ||||||||||||||||
Rated work curret le AC-33A | 20 | 40 | 63 | 80 | 100 | 125 | 160 | 250 | 400 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3200 |
Rated connection capability | 10 le | ||||||||||||||||
Rated breaking capability | 10 le | ||||||||||||||||
Rated conditional short-circuit current | 100KA | 70KA | 100KA | 120KA | 80KA | ||||||||||||
Rated short-time withstand current IS | 7KA | 9KA | 13KA | 26KA | 50KA | 55KA | |||||||||||
Transfer time I-II or II -I | 0.45s | 0.6s | 1.2s | 2.4s | |||||||||||||
Control voltage of the switch motor | DC24V AC220V AC280V |
1, Double complex contact, horizontal and vertical type frame basically, it have come to "Zero" arc(no arc chute); |
2, Reliable machine interlock and elecric interlock, the executive union parts adopt independency overload disconnect switch, it makes more reliable and safety. |
3, "zero" techinique, can force to set"zero" under emergency situation(break off two ways power supply at the same time).Meet the requirement of the fire protection linkage. |
4, Operate overload disconnect switch change over adopt singless electromotor drive, switch over smooth and reliable, no noise, little wallop |
5, Operate machine drive motor use only under the executive overload disconnect switch change over instanecus current across, outstanding energy saying. |
6, Perform overload disconnect switch with mechanism interlock device. It ensure the common use, standby power working reliable and not interference. |
7, Distinct on and off position indicator, padlock function et.c safe realize the isolator between electric power and overload |
8, High security, high automatization, high retiablility, use life more than 8000times |
Item No | Qty/Carton | Net Weight(KGS) | Gross weight (KGS) | Carton Size (MM) | ||
L | w | H | ||||
SKT2-100/X/CK | 6 | 21 | 26.5 | 375 | 330 | 640 |
SKT1-125/M1/CK | 4 | 21.2 | 26.5 | 510 | 375 | 440 |
SKT1-160/M1/CK | 4 | 21.2 | 26.5 | 510 | 375 | 440 |
SKT1-250/M1/CK | 4 | 28 | 34 | 510 | 445 | 440 |
SKT1-400/N/CK | 2 | 34 | 38 | 535 | 340 | 685 |
SKT1-630/N/CK | 2 | 34 | 38 | 535 | 340 | 685 |
SKT1-800/N/CK | 1 | 39.7 | 46.7 | 665 | 360 | 370 |
SKT1-1000/N/CK | 1 | 40.5 | 47.5 | 665 | 360 | 370 |
SKT1-1250/N/CK | 1 | 41 | 48 | 665 | 360 | 370 |
SKT1-1600/N/CK | 1 | 49 | 56 | 665 | 360 | 370 |
SKT1-2000/N/CK | 1 | 98 | 109 | 670 | 550 | 590 |
SKT1-2500/N/CK | 1 | 100 | 111 | 670 | 550 | 590 |
SKT1-3200/N/CK | 1 | 10 | 113 | 670 | 550 | 590 |