Features &Benefits:
  1. 12.1" color TFT display, high resolution: 800×600dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
  4. Real time S-T segment analysis, and ARR analysis;
  5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  6. Parameter waveform and characters color selectable
  7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  8. Standby mode for Energy saving and suspend monitoring;
  9. 7-lead ECG waveforms display in phase;
  10. Capture dynamic waveforms;
  11. Built-in rechargeable lithium battery, and battery volume checking,
  12. AC power checking
  13. Efficient resistance to interference of defibrillator and HF knife;
  14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  15. Networking capacity and TCP/IP networking platform enable abundant future upgrade
  16. Time delay switch-off function keep the monitor data restart monitor;
  17. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,



Performance Specifications
Display:                 12.1"color TFT
Rolling and refreshing waveform display
Resolution: 800×600
Multi display selectable including:
Large-font display
Trend coexist display
OxyCRG dynamic view display.
Bed-to-bed view display
Trace:                9 waveforms(7 ECG, 1 SPO2 and 1 RESP)
Sweep speed:12.5mm/s,25mm/s,50mm/s
Indicator:             Power/battery indicator light
QRS beep and alarm sound
Battery:               Rechargeable lead acid cell, 12v/4AH
Max.24 hour for charging, 4 hours for continue working
Trend:             Parameter graphic and tabular trends:
5s/piece,8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece,1000 hours.

Storage:           NIBP: 1000 groups
Alarm: 200 groups
Full disclosure waveforms: 3600S
SD card external storage
Alarm:                    User-adjustable High, Medium and Low limits 3-level
 Audible and visual alarm
Networking:          Connected to central monitoring system
TCP/IP netting platform
Recorder:              Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type:        Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record

Standard parameter:
ECG:

Lead mode:                                5 -lead(R,L,F,N,C)
Lead selection :                         I,II,III,avR,avL,avF,V
Waveform:                          3 and 7 channel selectable
Gain selection:                         0.5mm/mv,1mm/mv,2mm/mv
Sweep speed:                          12.5mm/s;25mm/s;50mm/s
Heart rate range:                       Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy:                                   +1bpm or +1%,whichecer is greater
Resolution:                          1bpm
Filter:                                            surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal:                           1mv,+3%
Protection:                         withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:                             15~350bpm
S-T segment detecton:                  
Measurement range:  2.0mV~+2.0mV                         
 
 Alarm Range:         -2.0mV~ +2.0mV
Accuracy:            -0.8mV ~+0.8Mv
Error:               +0.02Mv
 
Arrhythmia analysis:      YES

SPO2
Measurement range:        0~100%
Resolution:                1%
Accuracy:                 +2%(70-100%);0-69% unspecified
Alarm range               0~100%
Pluse Rate:               
range:        20~300bpm
Resolution:   1bpm
Error:        +1bpm or +2%,whichever is greater

NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic/continuous
Auto measurement time:      Adjustable(1~480min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean 
Measurement tange:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                    Systolic.Diastolic,Mean


RESPIRATION
Method:                     Thoracic impedance
Measurement range:           Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm:                 YES,10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm


TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution :                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1
Average measuring time:        <10s

FHR
Transducer:   Multi-crystal, Pulsed Doppler
Measurement range:  50~210 BPM
Working frequency:   1 MHz
Strength:   <5mW/cm2
Signal processing: 
special DSP system and modern recognization.
Resolution:   1BPM
Accuracy:    ±1BPM
Alarm Range:  High: 160,170,180,190 BPM,
Low: 100,110,120 BPM

FM
Manual button marking,
automatic FM identifying function

TOCO Measuring
Transducer:  External pressure transducer
Measurement range:  0~100 units
Resolution:  1rpm
Accuracy:  ±2 rpm


IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP

EtCO2( Sidertream CO2)
Measurement range:   0~99mmHg
Accuracy:   +2mmHg (0~40mmHg)
Sampling Range:   100ml/min
Sampling rate accuracy:   15%
Respiration rate:   0~120rmp
Respiration accuracy:  +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time:   <240msec (10% to 90%)
Delay time:  <2s

EtCO2 (mainstreaam CO2)
Method:   Infrared Spectrum
Range:   0.0-10% (0~76%)
Resolution:   1mmHg (0.1%)
Accuracy:   <5%(±4.0 mmHg)
         Or<10%(of Readings)

Recorder:     
Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type:  Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record