Hybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000W

China Hybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000W, Find details about China off Rid Inverter, on Grid Inverter from Hybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000W

Type
DC/AC Inverters
Power Source
Solar Power
Nature of Wave String
Sine Wave Inverter
Efficiency (DC to AC)
93.5%
Frequency Range
50Hz/60Hz (Auto Sensing)
Maximum AC Input Current
60A
Maximum Solar Charge Current
100A
Acceptable Input Voltage Range
90-280VAC or 170-280 VAC
Phases
Single Phase
Trademark
longcom
Specification
100 x 300 x 440
Origin
China
Type
DC/AC Inverters
Power Source
Solar Power
Nature of Wave String
Sine Wave Inverter
Efficiency (DC to AC)
93.5%
Frequency Range
50Hz/60Hz (Auto Sensing)
Maximum AC Input Current
60A
Maximum Solar Charge Current
100A
Acceptable Input Voltage Range
90-280VAC or 170-280 VAC
Phases
Single Phase
Trademark
longcom
Specification
100 x 300 x 440
Origin
China
Hybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000W

 Key Features:

 
Pure sine wave solar inverter
Output power factor 1
Parallel operation up to 9 units
High PV input voltage range
Battery independent design
Built-in 100A MPPT solar charger
Battery equalization function to optimize battery performance and extend lifecycle
Built-in anti-dusk kit for harsh environment
REVO VM II Series Off Grid Energy Storage Inverter
Anti-Dust Kit:
After installing this anti-dust kit, inverter will automatically detect
this kit and activate internal thermal sensor to adjust internal
temperature. By virtue of the dustproof design, it dramatically
increases product reliability in harsh environment.

 

 

 

 

Hybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000WHybrid Solar Inverter MPPT DC 12V 24V 48V 220V AC on off Grid Power Inverter 1kw 2kw 3kw 4kw 5kw 3000W 5000W

 

Product Parameters
REVO VM II Series
Wall Mounted Integrated Solar Inverter Technical Specifification
Built-in MPPT Solar Controller
MODELREVO VM II 3000-24REVO VM II 5500-48
Rated Power3000VA / 3000W5500VA / 5500W
INPUT
Voltage230 VAC
Selectable Voltage Range170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances)
Frequency Range50 Hz/60 Hz (Auto sensing)
OUTPUT
ACVoltage Regulation(Batt. Mode)230VAC ± 5%
Surge Power6000VA11000VA
Efficiency (Peak)90% ~ 93%
Transfer Time10 ms  (For Personal Computers) ; 20 ms (For Home Appliances)
WaveformPure sine wave
BATTERY
Battery Voltage24 VDC48 VDC
Floating Charge Voltage27 VDC54 VDC
Overcharge Protection33 VDC63 VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage500 VDC500 VDC
Maximum PV Array Power55005500 W
MPP Range @ Operating Voltage120~450 VDC120~450 VDC
Maximum Solar Charge Current100 A100 A
Maximum AC Charge Current80 A80 A
Maximum Charge Current100 A100 A
PHYSICAL
Dimension, D x W x H (mm)100 x 300 x 440
Net Weight (kgs)910
Communication InterfaceUSB/RS232
ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C

 

 
FAQ

1. How to choose suitable inverter?
 
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
 
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
 
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................

2. How do I choose the size of the inverter?
 
Different types of load demand for power are different. You can view the load power values to determine the 
size of the power inverter.
 
Notice:
 
Resistive load: you can choose the same power as the load. 
 
Capacitive loads: according to the load, you can choose 2-5 times power.
 
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
 
3. How connection between batteries and an power inverter?
 
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
 
4. How to calculate the load of working hours requires configuration of the battery size?

 
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
 
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)