China Patient Health Monitoring Hospital Portable 7 Inch Color TFT LCD Vital Signs Monitor, Find details about China Vital Signs Monitor, Monitoring Vitals from Patient Health Monitoring Hospital Portable 7 Inch Color TFT LCD Vital Signs Monitor
General | |
Product name | 7 Inch Color TFT LCD Vital Signs Monitor |
Size and Weight | Size: 160x130x260mm (WxHxD) Weight: (2.5 kg) (Including a lithium battery) |
Display | Type: 7" Color Anti-glare TFT LCD Resolution: 234x480 pixels |
Power supply | Input voltage: AC: 100V~240V, 50Hz/60Hz Input power: 70VA |
Battery | Type: 11.1V 4000mAh rechargeable lithium ion battery Operating time: >8 hours Charge time: 6h to 100% ( Standby) |
Data Storage | Clinic Mode: Patient quantity: 1000 Recording number: 16000 Single patient clinic record number: 1~16000 Monitor Mode: Patient quantity: 1 Trend data: resolution 1Min: can store 96 hours resolution 5 Min: can store 480 hours resolution 10 Min: can store 960 hours Alarm events: 1000 NIBP measurement record: 5000 |
Environmental Specifications | Operating Temperature: (5~40) C Humidity : <85% (noncondensing) Atmospheric Pressure: (700~ 1060) hPa Transportation and Storage Temperature: (-20~ +55) Humidity : ≤93% (noncondensing) Atmospheric Pressure: (500~ 1060) hPa |
PR | Measurement range: 20~ 250 bpm Resolution: 1 bpm Accuracy: ±1% or±1 bpm, whichever is the greater |
Performance | |
BLT Digital SpO2 | Measurement range (0~ 100) % Resolution: 1% Accuracy:±2% (70%~ 100%) ±3% (35%~69% ) unspecified (0~34% ) |
Masimo SpO2(Option) | Measurement range: (0~100)% Resolution: 1% Accuracy:±2% (70% to 100% ) (adult/pediatric, non-motion conditions) ±3% (70% to 100%) (neonate, non-motion conditions) ±3% (70% to 100%) (motion conditions) Unspecified (0% to 69% ) |
Nellcor SpO2 (Option) | Measurement range: (0~ 100) % Resolution: 1% Accuracy:±2% (70%~ 100%) (adult) ±3% (70%~100%) (neonate ) ±2% (70%~ 100%) (low perfusion) unspecified (0~69)% |
NIBP | Technique: Automaticoscillometry Range: Adult: 10~ 270mmHg Child: 10~235mmHg Neonate: 10~135mmHg Accuracy: Static ±3 mm Hg Clinic: Average error: ±5 mmHg standard deviation: ≤8 mmHg Unit: mmHg.kPa Pulse rate range: 40-240 bpm |
Microstream EtCO2 (Option) | Measurement way: Infrared spectrum Measurement mode: sidestream Sample flow rate: 50 ml/min±10 ml/min Measurement range: (0~19.7) %,(0~150 mmHg) Resolution: 0.1% or 1mmHg Unit: %, mmHg, kPa Accuracy: ±2 mmHg 0 mmHg to 40 mmHg, ±5% of reading 41 mmHg to 70 mmHg, ±8% of reading 71 mmHg to 100 mmHg, ±10% of reading 101 mmHg to 1 50 mmHg, ( 760mmHg, temperature is 25 °C ) (when RR > 80 rpm, all the range is ±12% of reading) |