Conductor De Aluminio (AAAC)
1.Applacation of aaac (Conductor De Aluminio) conductor
The AAAC is used for overhead power transmission lines , especially the electric power augmentation of old transmission lines. We specialized in the research and application of AAAC for almost ten years. When replacing the aluminium conductor steel reinforced , the AAAC can save 5-8% of the construction cost. This AAAC covers aluminium alloy (hard solution, heat-treated, cold worked, and artifically aged) round wires for electrical purposes to be used as component wires of alu246.7 MCM AAAC Conductor with AAAC Allianceminium alloy conductor and aluminium alloy conductor steel reinforced.
2.Specification of aaac (Conductor De Alumino) conductor
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6) rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7) aluminimum conductor aluminimum alloy reinforced(ACAR)
3.General standard of aaac (Conductor De Aluminio) conductor
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) as per BS-215-II-1970
(AACSR) as per IEC-1089-1191
4.Technical data sheet of AAAC (Conductor De Aluminio) Conductor
sectional area | core number/diameter | count sectional area | outside diameter(mm) | direct current resistance | pulling strength | weight |
(mm²) | (mm) | (mm²) | (Ω/km) | (N) | (kg/km) |
16 | 7/1.70 | 15.89 | 5.1 | 1.802 | 2340 | 43.5 |
25 | 7/2.15 | 25.41 | 6.45 | 1.127 | 4355 | 69.6 |
35 | 7/2.50 | 34.36 | 7.5 | 0.8332 | 5760 | 94.1 |
50 | 7/3.00 | 49.48 | 9 | 0.5786 | 7930 | 135.5 |
70 | 7/3.60 | 71.25 | 10.8 | 0.4018 | 10950 | 195.1 |
95 | 7/4.16 | 95.14 | 12.48 | 0.3009 | 14450 | 260.5 |
120 | 19/2.85 | 121.21 | 14.25 | 0.2373 | 19420 | 333.5 |
150 | 19/3.15 | 148.07 | 15.75 | 0.1943 | 23310 | 407.4 |
185 | 19/3.50 | 182.8 | 17.5 | 0.1574 | 28440 | 503 |
210 | 19/3.75 | 209.85 | 18.75 | 0.1371 | 32260 | 577.4 |
240 | 19/4.00 | 238.76 | 20 | 0.1205 | 36260 | 656.9 |
300 | 37/3.20 | 297.57 | 22.4 | 0.09689 | 46850 | 820.4 |
400 | 37/3.70 | 397.83 | 25.9 | 0.07247 | 61150 | 1097 |
500 | 37/4.16 | 502.9 | 29.12 | 0.05733 | 76370 | 1387 |
630 | 61/3.63 | 631.3 | 32.67 | 0.04577 | 91940 | 1744 |
800 | 61/4.10 | 805.36 | 36.9 | 0.03588 | 115900 | 2225 |
We could produce most of the standards cables, such as ASTM, BS, CSA, DIN, GB and IEC Standards, etc.
ISO9001:2008, OHSAS, CCC, TUV Certifications.
People's Cable Group Co., Ltd. Was founded in 2007, With good transport facilities which adjacent to the 310 national highway-Lian Huo highway. Our company had 2 factories(Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than 10 million USD, with 630 staff members, 65 of which are professional and technical experts, which is a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.