High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures

China High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures, Find details about China Flux Cored Welding Wires, Low Temperature Welding Wire from High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures

Model NO.
AWS A5.29 E81T1-K2C
Trademark
TOKO
Specification
0.9mm, 1.0mm, 1.2mm, 1.4mm, 1.6mm
Origin
China
HS Code
83112000
Model NO.
AWS A5.29 E81T1-K2C
Trademark
TOKO
Specification
0.9mm, 1.0mm, 1.2mm, 1.4mm, 1.6mm
Origin
China
HS Code
83112000
 TOKO High Tensile Steel Flux Cored Welding wire for low temperatures

Flux Cored Welding Wire AWS A5.29 E81T1-K2C
EN ISO 1763-A-T 46 6 1.5Ni  P C 1 H5
High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures

Characteristics and Application:

TOKO Brand, High tensile steel AWS A5.29 E81T1-K2C for low temperature (-60ºC),  a titania type flux-cored wire, is designed for welding 560 N/mm2 high tensile steel for low temperatures. The weld metal contains about 1.5%-Ni and makes good notch toughness at temperatures down to -60ºC under as welded condition.

It provides excellent usability with stable arc and efficiency in all-position welding. It is suitable for butt or fillet welding of offshore structures for low-temperature districts, LNG and LPG carriers, and storage tanks, etc. 
High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures

Mill Test Certificate:       

Contract No.: TOKO20191202                           
Mfg date: 12/22/2019                       
Specification: φ1.2MM                          
Weight: 23520Kg                         

Chemical Composition of deposited metal (%)

Item

C

Mn

Si

P

S

Cr

Ni

Mo

V

Standard

≤0.15

0.50~1.75

≤0.80

≤0.030

≤0.030

≤0.15

1.00~2.00

≤0.35

≤0.05

Test

0.05

1.25

0.20

0.012

0.007

0.02

1.20

0.003

0.007

Mechanical Properties of Deposited Metal

Item

Yield Strength

(MPa)

Tensile Strength

(MPa)

Elongation

(%)

Charpy V-notch Impact Toughness

Welding Condition

Test Temp.

(ºC)

Impact Energy

(J)

Average

(J)

Type of Current

Amperage

Arc Voltage

Shielding Gas

Standard

≥470

550~690

≥19

-30

≥47

 

DCEP

250-280A

28-30V

CO2

Test

590

651

26.5

-40

70  71  72

71

DCEP

250-280A

28-30V

CO2

Radiographic Test: PASS                       Fillet Weld Test:PASS       
Classification:AWS A5.29 E81T1-K2C              Lot No.: 91222712

TOKO, we hereby certify that this report is correct and that all test results are in compliance with the specification described herein.

Inspector: Zhang mei      
Quality Director: Ma Xue                                  
Date: 2019-12-23                     
TOKO Group Ltd               
High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures
High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures

High Tensile Steel Flux Cored Welding Wire Aws A5.29 E81t1-K2c for Low Temperatures