China Zlpower Shenzhen Rack&Towel High Frequency Online UPS 1kl 2kl 3kl 6kl 10kl, Find details about China Rack Towel UPS, High Frequency Online UPS from Zlpower Shenzhen Rack&Towel High Frequency Online UPS 1kl 2kl 3kl 6kl 10kl
Model | RT1K | RT1KL | RT2K | RT2KL | RT3K | RT3KL | RT6K | RT6KL | RT10K | RT10KL | ||
Capacity | VA/W | 1000VA/800W | 1000VA/800W | 2000VA/1600W | 2000VA/1600W | 3000VA/2400W | 3000VA/2400W | 6000VA/4800W | 6000VA/4800W | 10000VA/8000W | 10000VA/8000W | |
Input | Nominal Voltage | 200/208/220/230/240VAC | ||||||||||
Voltage Range | 115~300VAC | 120~275VAC | ||||||||||
Power Factor | ≥0.98 | ≥0.99 | ||||||||||
Frequency Range | 50Hz:46~54Hz; 60Hz:56~64Hz | |||||||||||
Output | Voltage | 200/208/220/230/240(1±1%)VAC | 200/208/220/230/240(1±1%)VAC | |||||||||
Frequency | 50/60Hz (Adjustable); 50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%) 60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%) | |||||||||||
Wave Form | Pure sine wave | |||||||||||
Power Factor | 0.9 | |||||||||||
Harmonic Distortion | ≤4% THD (Linear load) ≤7% THD (Non-Linear load) | ≤2% THD (Linear load) ≤4% THD (Non-Linear load) | ||||||||||
Overload Capacity | 105%~150% maintain 25s-45s then turn to bypass ourput 150%~200% maintain 300ms-25s then turn to bypass ourput ≥200% maintain 200ms then turn to bypass ourput | Load <105% work consistant; 105%<load <125% 1min; 125%<load <150% 30sec | ||||||||||
Current Crest Ratio | 3:01 | |||||||||||
Connections | IEC320-10A*6 | IEC320-10A*8 | IEC320-10A*8 | Terminal block | ||||||||
Efficiency | Battery Mode | 89% | 87% | |||||||||
AC Mode | 94% | 88% | ||||||||||
Battery | Type | Sealed free maintenance lead acid battery | ||||||||||
Nominal DC voltage | 24VDC | 24VDC | 48VDC | 48VDC | 72VDC | 72VDC | 192VDC | 192VDC | 192VDC | 192VDC | ||
Battery Numbers&Capacity | 2*12V 9AH | Long backup | 4*12V 9AH | Long backup | 6*12V 9AH | Long backup | 16*12V 9AH | Long back up | 16*12V 9AH | Long back up | ||
Backup Time (Full Load) | ≥2.5min | Depens on capacity of external battery bank | ≥3min | Depens on capacity of external battery bank | ≥3min | Depens on capacity of external battery bank | ≥5min | Depens on capacity of external battery bank | ≥4min | Depens on capacity of external battery bank | ||
Charge Current (Max) | 1.0A | 2.0A | 1.0A | 2.0A | 1.0A | 2.0A | 1.0A | 4.5A | 1.0A | 4.5A | ||
Charge Voltage (VDC) | 27.4V±0.2VDC | 27.4V±0.2VDC | 54.8V±0.4VDC | 54.8V±0.4VDC | 82.2V±0.6VDC | 82.2V±0.6VDC | 218.4V±2VDC | 218.4V±2VDC | 218.4V±2VDC | 218.4V±2VDC | ||
Recharge Time | 5hours to 90% | Depends on the capacity of internal battery bank | 5hours to 90% | Depends on the capacity of internal battery bank | 5hours to 90% | Depends on the capacity of internal battery bank | 7hours to 90% | Depends on the capacity of internal battery bank | 7hours to 90% | Depends on the capacity of internal battery bank | ||
Bypass | Automatic Transfer | On overload and UPS failure | ||||||||||
Before UPS Power-on | YES | |||||||||||
Transfer Time | 0 ms(from imain to battery and vice versa); Less than 4ms from inverter to bypass and vice versa | |||||||||||
indicators | LCD Display | UPS status, Battery capacity, loading, Fault code (LCD: I/P&O/P voltage&frequency, Battery voltage) | ||||||||||
Audible | Bypass, Battery mode, Battery low, Overload, Fault | |||||||||||
Communications | Intelligent RS232 serial port | Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC | ||||||||||
SNMP (Optional) | Remote control UPS through SNMP management and Internet | |||||||||||
USB (Optional) | Windows family software and Mac OS | |||||||||||
Environmental | Operating Temperature | 0~40ºC | ||||||||||
Operating Humidity | 20~90% (No condensing) |