440V 25kvar Three Phase Power Factor Correction Unit for Sale

China 440V 25kvar Three Phase Power Factor Correction Unit for Sale, Find details about China Power Capacitor, Power Factor Correction Capacitor from 440V 25kvar Three Phase Power Factor Correction Unit for Sale

Model NO.
BSMJ0.44-25KVAR-3
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Tuning, Filter, Low Frequency Bypass
Tuning
Polystyrene Capacitor
Filter
Composite Paper Capacitor
Compensate
Reactive Energy
Power Transformer
Prove Transmission Power Factor
Using Range
Motor or Inductive Power
Power Supply
Only Supply Reactive for Load
Warranty
2 Years
Di Electrical
50 Degree Solid Wax
Trademark
OEM
Transport Package
Wooden
Specification
CE ROHS
Origin
Zhejiang Yueqing
HS Code
85321000
Model NO.
BSMJ0.44-25KVAR-3
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Tuning, Filter, Low Frequency Bypass
Tuning
Polystyrene Capacitor
Filter
Composite Paper Capacitor
Compensate
Reactive Energy
Power Transformer
Prove Transmission Power Factor
Using Range
Motor or Inductive Power
Power Supply
Only Supply Reactive for Load
Warranty
2 Years
Di Electrical
50 Degree Solid Wax
Trademark
OEM
Transport Package
Wooden
Specification
CE ROHS
Origin
Zhejiang Yueqing
HS Code
85321000
440V 25KVAR three phase Power Factor Correction Unit for Sale
What is reactive power

How does reactive power come into being? The AC system provides two forms of electric energy, active power and passive power.
Active power: All inductive devices operating in the AC system convert electrical energy from the power supply system into mechanical energy and thermal energy, which is called active power.
Reactive power: In order to achieve this transformation, it is necessary to establish magnetic fields in the equipment, and these magnetic fields are related to another form of electrical energy provided in the power supply system, which is called reactive power energy.
The existing forms of reactive power are as follows:
Reactive Power (Transformer, Motor, etc.) Required by Inductance Circuit
Reactive Power (Cable, etc.) Required by Capacitance Circuit
Active power KW = P, reactive power KVAR = Q, inductance reactive power + Q, capacitor reactive power - Q
Apparent power KVA = S
As long as the user has electric load such as motor transformer on site, he will consume reactive power, so the demand for reactive power is just needed for the user.
What is the power factor?
The power factor is the active power KW. The closer the power factor is to the maximum value of 1, the more favorable PF = P (KW)/S (KVA) is for users and power supply departments.
For example, if the power factor is only 0.7, if the power factor is not up to the standard, there will be a penalty for the electricity charge. The power factor reaches 0.95. If the power factor exceeds the assessment index, the power supply bureau will award a calendar.
Increase of efficiency
Correction of Power Factor to Improve Equipment Efficiency
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale
440V 25kvar Three Phase Power Factor Correction Unit for Sale