PRF Power factor correction
The power factor approve state of user
To improve the utilization efficiency of electric transformer
Reducing line loss
To improve the voltage quality of power supply
Automatic power factor controller
Item | Name | PFR power factor correction |
1 | LED/LCD Display will show a.three-phase voltage,current, active power, reactive b.power factor and power network frequency, control parameter |
2 | Strong anti-interference ability can resist 2kv impulse test ,keep data |
3 | You can revise control data sheet ,it will save data no power |
4 | Auto analysis phase function |
5 | Current get signal resistor less than 0.05Ω |
6 | Over voltage ,under voltage lack phase protection function |
7 | Input way: static ,Dynamic ,compound |
8 | Rated voltage | AC 220V±10% AC 380V±10% |
9 | Rated current | AC 0-5A |
10 | Rated frequency | 50Hz±5% |
11 | Sensitivity | 100mA |
12 | COS φ Preset | 0.80-0.99; step length 0.01; Factory preset 0.98 input and cutoff time |
13 | Input Delay | dynamic state 100ms-30S; Static state 1-250S;Factory preset dynamic state 5S; static state 30S. |
14 | Over-voltage protection | 230-260V; step length 1V; Return difference 6V reset 240V, |
15 | Under-voltage protection | 180V;return difference 6V |
16 | Auto Discriminating Phase | ON/OFF; factory preset ON(Auto discriminating ON) |
17 | Reactive threshold | OFF-4-100kvar; factory preset OFF (reactive threshold inefficiency) |
18 | CT variation | 50/5A-3000/5A; step length 1; factory preset 500/5A |
19 | Capacitance capacity | 0-99kvar factor preset of each branch 10kvar |
20 | Contact capacity | dynamic state output of each branch DC12V×50mA Static state output of each branch 380V×7A/200V×5A |
21 | size | 113*113 138*138 |
PRF Power factor correction advantage
1.20 years global leading profession manufacture of energy meter
2, the precision of measurement
The current identification: the controller can judge the sampling current polarity and automatic conversion.
3, the display of choice
4, parameter setting function
5, protection function
6. control strategy, capacitors
7. output circuit design
8.Fast delivery : you will get the order when you need it
9.OEM is warmly welcome
10.Convenient : 45 minutes to wenzhou airport
PRF Power factor correction function
Control signal: comprehensive control by using the power factor and reactive current of two physical quantities;
Step :step number selected by the user;
Data storage: after the loss of electricity parameter settings will not be lost, data save permanently;
Adaptability: automatically adapt to the distribution system of different parameters of the controller, does not need to provide the transformation ratio of current transformer and capacitor compensation capacity;
Overvoltage protection: the voltage is higher than the set value quickly over voltage, gradual resection capacitors have been put;
Strong anti-interference: unique design, crash, indiscriminately, indiscriminate cutting phenomenon can not occur in operation;
Switching shocks: can prevent the small current load and over voltage critical values appear repeated switching;
High sensitivity: compensator can work normally in the input signal when the current is 0.10A;
Display error: input signal power of current 0.10A to 5A changes due tonumerical error measurement showed minimal;
The current identification: the controller can judge the sampling current polarity and automatic conversion.
PRF Power factor correction Payment terms
1. 30% T/T advance , the balance against to the copy B/Lor LC at sigh
2. The other specific issues can negorate.
3. Pls confirm the details with us before do the prepayment.
PRF Power factor correction Packing information
1. Inside foam package ,outside strong paper package
2. 12pcs/per CTN
3. G/N.W: 12/11kg
4. We can packing as your required,good looking design
Why choose PRF Power factor correction
1).ISO9001,SGS,Gold golden supplier
2) Monthly Production Capacity -- 100000 Pcs
3)All goods examined before delivery by 10 QC staff
4)Prompt Reply Within 12 Hours
5)8000 square meters work environment