China Hybrid off Grid Inverter with MPPT 40A/60A Solar Charger Controller, Find details about China off Grid Inverter, Solar Power Inverter from Hybrid off Grid Inverter with MPPT 40A/60A Solar Charger Controller
Parameters | GW Plus1KW | GW Plus2KW | GW Plus3KW | |
AC Input | Nominal Power | 1000W | 2000W | 3000W |
Input Voltage Waveform | Sinusoidal (utility or generator) | |||
Nominal input Voltage | 120/230VAC | |||
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |||
Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |||
High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |||
High Line Re-connect | 131Vac±4%(Normal) or 135Vac±4% (Wide) for 120V 253Vac±4%(Normal) or 253Vac±4%(Wide) for 230V | |||
Max AC input Voltage | 120V for Max150V / 230V for Max270V | |||
Frequency | 50Hz:41-54Hz / 60Hz:51-64Hz | |||
AC output | Output Voltage Waveform | Sine wave | ||
Power Factor | 0.9~1.0 | |||
Nominal Output Voltage (V) | LV:120Vac ±10%rms / HV:230Vac ±10%rms | |||
Nominal Output | 50Hz ± 0.3Hz / 60Hz ± 0.3Hz | |||
Frequency (Hz) | ||||
Transfer Time | 20ms(max) | |||
Solar charger | Rated Charge Current | 40A | 60A | |
PV Input Voltage range | 30VDC-55VDC for 24VDC / 60-110VDC for 48V | |||
Max. PV open circuitarray voltage | 12V for 40Vdc,24V for 55Vdc,48V for 110Vdc | |||
Charger mode | MPPT | |||
Efficiency | ≥97% | |||
AC Charger | Nominal Charger | 35A/50A/70A/90A(According to the inverter model) | ||
Current | 5 stages adjustable charging current | |||
Over charge Protection | Bat.V≥15.5VDC for 12V battery,Bat.V≥31.0VDC for 24V battery,Bat.V≥62.0VDC for 48V battery ,beeps 0.5s every 1s & fault after 60s | |||
Efficiency | Efficiency(Battery Mode) | ≥87% | ||
Efficiency (Line Mode) | >98% | |||
Battery Voltage | Nominal DC input Voltage | 12/24/48VDC | ||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | |||
21VDC±0.6VDC for 24VDC | ||||
42VDC±1.2VDC for 48VDC | ||||
High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC | |||
32VDC±0.6VDC for 24VDC | ||||
64VDC±1.2VDC for 48VDC | ||||
System Paramete | Over-Load Protection | 110%150%,beeps 0.5s every 1s,and Fault after 20s | ||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||
Surge Rating(10s) | 1:3(VA) | |||
Protections | Low battery, over charging, over load, over temp | |||
General Specifications | Storage Temperature | -15ºC~60ºC | ||
Audible Noise | 60dB max | |||
cooling | Forced air , variable speed fan | |||
Dimension(L*W*H) | 480*336*190mm | |||