Hybrid off Grid Inverter with MPPT 40A/60A Solar Charger Controller

China Hybrid off Grid Inverter with MPPT 40A/60A Solar Charger Controller, Find details about China off Grid Inverter, Solar Power Inverter from Hybrid off Grid Inverter with MPPT 40A/60A Solar Charger Controller

Model NO.
GW Plus Series
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Rated Power
1000~12kw
Input Voltage
120/230VAC
Efficiency(Battery Mode)
>=85%
Efficiemcy(Line Mode)
>96%
Battery Voltage
12/24/48V
AC/DC Priority Modes
Yes
Restart
Generator Restart Signal
Peak Power
3times
Protection
Overload, Output Short-Circuit
Display
LED/LCD
Trademark
ZLPOWER
Transport Package
Standard Export Package
Specification
Depend
Origin
Mainland(China)
HS Code
8504403090
Model NO.
GW Plus Series
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Rated Power
1000~12kw
Input Voltage
120/230VAC
Efficiency(Battery Mode)
>=85%
Efficiemcy(Line Mode)
>96%
Battery Voltage
12/24/48V
AC/DC Priority Modes
Yes
Restart
Generator Restart Signal
Peak Power
3times
Protection
Overload, Output Short-Circuit
Display
LED/LCD
Trademark
ZLPOWER
Transport Package
Standard Export Package
Specification
Depend
Origin
Mainland(China)
HS Code
8504403090
GW Plus. with MPPT solar charge controller can maximize and regulate DC power from solar array to charge battery bank.to start up motor-type loads such as refrigerators,motors,pumps,compressor and laser printers as well as electronic loads like TV's, Computers and power tool,etc.

Features:
AC/Solar charge hybrid off grid inverter.
LED/LCD display, Enhanced funvtions setting via LCD, Man-machine intelligent design.
Built-in 40A/60A MPPT solar charger controller.AC charging current. AC charging also can be closed.
AC/DC priority modes can be set.
Generator restart signal(Dry cotact).
3 times peak power, strong loading capacity.
Overload,output short-circuit protection.

 
                                      ParametersGW Plus1KWGW Plus2KWGW Plus3KW
AC
Input
Nominal Power1000W2000W3000W
Input Voltage WaveformSinusoidal (utility or generator)
Nominal input Voltage120/230VAC
Low Line  Disconnect85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V
Low Line  Re-connect95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V  194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V
High Line  Disconnect136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V  263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V
High Line Re-connect131Vac±4%(Normal) or 135Vac±4% (Wide) for 120V 253Vac±4%(Normal) or 253Vac±4%(Wide) for 230V
Max AC input Voltage120V for Max150V / 230V for Max270V
Frequency50Hz:41-54Hz / 60Hz:51-64Hz
AC
output
Output Voltage WaveformSine wave
Power Factor0.9~1.0
Nominal Output Voltage (V)LV:120Vac ±10%rms / HV:230Vac ±10%rms
Nominal Output50Hz ± 0.3Hz / 60Hz ± 0.3Hz
Frequency   (Hz)
Transfer Time20ms(max)
Solar
charger
Rated Charge Current40A60A
PV Input Voltage range30VDC-55VDC for 24VDC / 60-110VDC for 48V
Max. PV open circuitarray voltage12V for 40Vdc,24V for 55Vdc,48V for 110Vdc
Charger  modeMPPT
Efficiency≥97%
AC
Charger
Nominal Charger35A/50A/70A/90A(According to the inverter model)
Current5 stages adjustable charging current
Over charge ProtectionBat.V≥15.5VDC for 12V battery,Bat.V≥31.0VDC for 24V battery,Bat.V≥62.0VDC for 48V battery ,beeps 0.5s every 1s & fault after 60s
EfficiencyEfficiency(Battery Mode)≥87%
Efficiency (Line Mode)>98%
Battery
Voltage
Nominal DC input Voltage12/24/48VDC
Low Battery Alarm10.5VDC±0.3VDC for 12VDC
21VDC±0.6VDC for 24VDC
42VDC±1.2VDC for 48VDC
High DC input Alarm & Fault16VDC±0.3VDC for 12VDC
32VDC±0.6VDC for 24VDC
64VDC±1.2VDC for 48VDC
System ParameteOver-Load Protection110%150%,beeps 0.5s every 1s,and Fault after 20s
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Surge Rating(10s)1:3(VA)
ProtectionsLow battery, over charging, over load, over temp
General
Specifications
Storage Temperature-15ºC~60ºC
Audible Noise60dB  max
coolingForced air , variable speed fan
Dimension(L*W*H)480*336*190mm
Net Weight(kg)22.523.8