China 12kw off Grid Pure Sine Wave Solar Power Inverter, Find details about China Power Inverter, Solar Inverter from 12kw off Grid Pure Sine Wave Solar Power Inverter
Model Parameters | GS1000 | GS2000 | GS3000 | GS4000 | GS5000 | GS6000 | GS8K | GS10K | GS12K | |
AC Input | Nominal Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8KW | 10KW | 12KW |
Input Voltage Waveform | sinusoidal(utility or generator) | sinusoidal(utility or generator) | sinusoidal(utility or generator) | |||||||
Nominal input Voltage | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 120VAC/230VAC | 230VAC | 230VAC | 230VAC | |
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |||||||
Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |||||||
High Line Disconnect | 136Vac±4%(Normal) or 145Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |||||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | 120V for Max150V, 230V for Max270V | 230V for Max270V | |||||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | 50Hz:41-54Hz, 60Hz:51-64Hz | 50Hz:41-54Hz, 60Hz:51-64Hz | |||||||
AC Output | Output Voltage Waveform | Sine wave | Sine wave | Sine wave | ||||||
Power Factor | 0.9~1.0 | 0.9~1.0 | 0.9~1.0 | |||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | LV:120Vac ±10%rms, HV:230Vac ±10%rms | LV:120Vac ±10%rms, HV:230Vac ±10%rms | |||||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 50Hz ± 0.3Hz | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz | |||||||
Solar charger | Rated Charge Current | 40A | 60A | 60A/120A | 60A/120A | |||||
PV Input Voltage range | 15VDC-40VDC for 12VDC, 25VDC-75VDC for 24VDC, 55-145VDC for 48V | 25VDC-75VDC for 24VDC, 55-145VDC for 48V | 55-145VDC for 48V | |||||||
Max.PV open circuit array voltage | 12V for 40Vdc, 24V for 75Vdc, 48V for 145Vdc | 24V for 75Vdc, 48V for 145Vdc | 48V for 145Vdc | |||||||
Charger mode | MPPT | MPPT | MPPT | |||||||
PV Low Voltage Re-connect | PV≥Bat.V+3V | PV≥Bat.V+3V | PV≥Bat.V+3V | |||||||
PV Low Voltage Disconnect | PV<=Bat.V | PV<=Bat.V | PV<=Bat.V | |||||||
Efficiency | ≥97% | ≥97% | ≥97% | |||||||
AC Charger | Nominal Charger Current | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | 20A/35A/50A/70A/90A( 5 stages adjustable charging current) | ||||||
Over charge Protection | Bat.V≥15.5VDC for 12V battery Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | |||||||
Efficiency | Efficiency(Battery Mode) | ≥87% | ≥87% | ≥87% | ||||||
Efficiency (Line Mode) | >98% | >98% | >98% | |||||||
Battery Voltage | Nominal DC input Voltage | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 24VDC/48VDC | 24VDC/48VDC | 24VDC/48VDC | 48VDC | 48VDC | 48VDC |
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC 21VDC±0.6VDC for 24VDC 42VDC±1.2VDC for 48VDC | 21VDC±0.6VDC for 24VDC 42VDC±1.2VDC for 48VDC | 42VDC±1.2VDC for 48VDC | |||||||
Low DC input shut & down | 10VDC±0.3VDC for 12VDC 20VDC±0.6VDC for 24VDC 40VDC±1.2VDC for 48VDC | 20VDC±0.6VDC for 24VDC 40VDC±1.2VDC for 48VDC | 40VDC±1.2VDC for 48VDC | |||||||
High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC 32VDC±0.6VDC for 24VDC 64VDC±1.2VDC for 48VDC | 32VDC±0.6VDC for 24VDC 64VDC±1.2VDC for 48VDC | 64VDC±1.2VDC for 48VDC | |||||||
Transfer Time | AC to DC | 20ms(max) | 20ms(max) | 20ms(max) | ||||||
DC to AC | 15ms(max) | 15ms(max) | 15ms(max) | |||||||
System Parameter | Over-Load Protection | 110%<load<150%, beeps 0.5s every 1s, and Fault after 60s off the output,load>150%, beeps 0.5s every 1s, and Fault after 20s | 110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s | 110%<load<150%,beeps 0.5s every 1s,and Fault after 60s off the output,load>150%,beeps 0.5s every 1s,and Fault after 20s | ||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | Current limit (Fault after 10s) | Current limit (Fault after 10s) | |||||||
Surge Rating(10s) | 1:3(VA) | 1:3(VA) | 1:3(VA) | |||||||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | |||||||
Protections | Low battery, over charging, over load, over temp | Low battery, over charging, over load, over temp | Low battery, over charging, over load, over temp | |||||||
Indicators | LED+LCD Display | LED+LCD Display | LED+LCD Display | |||||||
General Specifications | Operating Temperature Range | 0ºC~40ºC | 0ºC~40ºC | 0ºC~40ºC | ||||||
Storage Temperature | -15ºC~60ºC | -15ºC~60ºC | -15ºC~60ºC | |||||||
Operation humidity | 5% to 95%(non-condensing) | 5% to 95%(non-condensing) | 5% to 95%(non-condensing) | |||||||
Audible Noise | 60dB max | 60dB max | 60dB max | |||||||
cooling | Forced air,variable speed fan | Forced air, variable speed fan | Forced air, variable speed fan | |||||||
Dimension(L*W*H) | 480*336*190mm | 530*400*190mm | 627*416*204mm | |||||||
Net Weight(kg) | 19.5kg | 23.5kg | 28kg | 30kg | 35.5kg | 39kg | 52.5kg | 58.5kg | 66.5kg |