China AC to DC 110V 5A 550W Switching Power Supply 30V 50V 60V 100V 120V 200V 300V 100A 200A 300A 400A 500A SMPS, Find details about China AC DC Power Supply, Compact Size Power Supply from AC to DC 110V 5A 550W Switching Power Supply 30V 50V 60V 100V 120V 200V 300V 100A 200A 300A 400A 500A SMPS
MODEL | HSJ-550-110 | |
OUTPUT | DC VOLTAGE | 110V |
RATED CURRENT | 5A | |
CURRENT RANGE | 0 ~ 5A | |
RATED POWER | 550W | |
RIPPLE & NOISE (max.) Note.2 | 300mVp-p | |
VOLTAGE ADJ. RANGE | 100~ 120V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±2.0% | |
SETUP, RISE TIME | 2500ms, 50ms/230VAC | |
HOLD UP TIME (Typ.) | 20ms/230VAC | |
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 176 ~ 264VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 91% | |
AC CURRENT (Typ.) | 1.2A/230VAC 0.6A/230VAC | |
INRUSH CURRENT(Typ.) | 50A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVER LOAD | 105 ~ 140% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 125~ 130V | |
Protection type :Hiccup mode, recovers automatically after fault condition is removed | ||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +60°C (Refer to derating curve) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85°C , 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | U60950-1 approved |
WITHSTAND VOLTAGE Note 6 | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |
OTHERS | MTBF | 235K hrs min. MIL-HDBK-217F (25°C ) |
DIMENSION | 215*115*50mm (L*W*H) | |
PACKING | 0.95Kg; 20pcs/20Kg/0.79CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |