Programmable Cyclic Corrosion Test Chamber
Description:
Cyclic corrosion testing simulates the closet actual natural environment, such as salt spray, drying, humidity and temperature alternating. The testing is strict than natural environment, and can be programmed or tested individually.
QCC510 Features:
1, Powerful LCD touch screen temperature and humidity controller
2, Optional recorder used to save temperature and humidity curve graph
3, Programmable control system, continuously and cyclic spray
4, Support power off memory, available to continue testing after power recovery
5, Auto or manual water refilling system makes sure non-stopping testing
6, Precision glass nozzle makes sure fog diffuses well-distributed
7, Auto descending and ascending system for testing cover, makes operation easy and safe
8, Clearly observe testing samples with auto defrost system
QCC510 Control System:
1, High precision P. I. D. Temperature controller to limit the temperature differences
2, Optional continuously or cyclic spray, apply fully automatic detecting system
3, Double over-heating protection systems protect both of chamber and operator.
4, Optional RS232 interface used to connect with computer
QCC510 Testing standards:
ISO9227-2012 Corrosion tests in artificial atmospheres salt spray tests
ASTM B117 Standard Practice for operating salt spray apparatus
JIS H8502 Methods of corrosion resistance test for metallic coatings
JIS Z2371 Methods of salt spray testing
IEC68-2-52 Test Kb: Salt mist, cyclic
CNS. 4158 method of salt spray (fog) test for surface finishing
ISO14993-2001 Corrosion of metals and alloys - Accelerated testing involving cyclic exposure to salt mist, "dry" and "wet" conditions
QCC510 Specifications:
Environment Temp. And Humid. Range: +5 deg~ +35deg / <85%RH
Air pressure: 86~ 106Kpa
Testing Temperature: NSS ACSS 35deg± 1deg; CASS 50deg± 1deg
Pressure Barrel Temperature: NSS ACSS) 47deg± 1deg; CASS 63deg± 1deg
Drying Test: Chamber temperature at 40deg-70deg( ± 0.5deg); Humidity at 30%-98% (± 5%RH)
Temperature and Humidity Test: Chamber temperature range is RTdeg-70deg(± 2deg) (Low temperature: Below 25deg without humidity)
Cooling Time: -70deg~RTdeg within 35min
Heating Time: RT-50deg within 60 min
Temperature Uniformity: ± 2deg
Humidity Range: 30%-98% (uniformity: ± 2%RH)
Solution Consistence: NaCi 5%
Model | QCC-270 | QCC-510 | QCC-816 | QCC-1200 |
Interior dimensions (mm) | W | 900 | 1200 | 1600 | 2000 |
D | 600 | 850 | 850 | 1000 |
H | 500 | 500 | 600 | 600 |
Exterior dimensions (mm) | W | 1460 | 2200 | 2600 | 3000 |
D | 910 | 1200 | 1450 | 1650 |
H | 1280 | 1450 | 1550 | 1600 |
Interior Volume | 270L | 480L | 800L | 1440L |
Solution Tank | 25 | 40 |
Power Supply | AC 220V /50HZ/1P | AC380V/50HZ/3P |
Environment temp. & humid. range | +5deg~ +35deg / <85%RH |
Air pressure | 86~ 106Kpa |
Testing Temperature | NSS ACSS 35deg±1deg / CASS 50deg±1deg |
Pressure barrel temperature | NSS ACSS) 47deg±1deg /CASS 63deg±1deg |
Drying test | Chamber temperature: 40deg-70deg( ±0.5deg), Humidity: 30%-98% (±5%RH) |
Temperature and humidity test | Chamber temperature range: RTdeg-70deg(±2deg) (Low temperature: below 25deg without humidity) |
Cooling time: -70deg~RTdeg within 35min Heating time:RT-50deg within 60 min |
Temperature uniformity: ±2deg Humidity range: 30%-98% (uniformity: ±2%RH) |
temperature humidity test | Temperature test:45deg±2deg | Humidity test:85%~98% ±2%RH |
Solution Consistence | NaCi 5% |
PH Value | NSS ACSS:6.5~7.2; CASS:3.0~3.2 |
Air pressure | 1.00±0.01kgf/cm2 |
Temperature fluctuation | <±0.5deg |
Temperature uniformity | <2. 0deg |
Temperature deviation | <±2.0deg |
Spray quantum | 1.0~2.0ml/80cm2/h |
Material | Polyvinyl chloride (P.V.C) |
Heater | Corrosion-resistant titanium tube |
Temperature sensor | Platinum Resistance PT-100 |
Controller | LCD touch screen temperature and humidity controller |
Safety device | Over-temperature protection , leakage protection |