China Climate Chamber for humidity/ temperature/ vibration/ low pressure environmental testing, Find details about China Climatic Chamber, Environmental Testing Chamber from Climate Chamber for humidity/ temperature/ vibration/ low pressure environmental testing
Specification:
Main technical parameters (ambient temperature +25 ºC and circulate water temperature +25 ºC, no specimen)
Model | CW/T0670W5 | CW/T1270W5 | CW/T2770W5 | ||||
with humidity-CW | CW/T0670W10 | CW/T1270W10 | CW/T2770W10 | ||||
without humidity-CT | CW/T0670W15 | CW/T1270W15 | CW/T2770W15 | ||||
Nominal interior volume ( L) | 613 | 1200 | 2730 | ||||
Performance | Temperature range | -70 ºC ~ +150 ºC | |||||
Humidity range | (20 ~ 98) %RH/ (20 ~ 85) ºC | ||||||
(only humidity type) | |||||||
Temperature fluctuation | ≤ 0.5 ºC (according to GB/T5170.2-2008) | ||||||
Temperature deviation | ±1.5 ºC | ||||||
Humidity deviation | ±3.0%RH(humidity > 75%RH), ±5.0%RH ( humidity ≤ 75%RH) | ||||||
(only humidity type) | |||||||
Temperature | 5/10/15 ºC/min (The whole process is average with standard load , | ||||||
change rate | and measured at the control point of inlet area under -55 ºC ~ +70 ºC ) | ||||||
Standard load | 15kg aluminium ingots, | 50kg aluminium ingots | 100kg aluminium ingots | ||||
350W heating power | 700W heating power | 1000W heating power | |||||
Inside dimensions | W | 800 | 1000 | 1300 | |||
(mm) | H | 1100 | 1200 | 1500 | |||
D | 700 | 1000 | 1400 | ||||
Power supply | 380V (three phase four wires + protective grounding wire) | ||||||
condensing method | Water-cooled |