Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC

China Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC, Find details about China Hba11c, HPLC from Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC

Report Range
3-18%
Autoloader Capacity
110 Tubes
Trademark
LABNOVATION
Transport Package
Carton
Specification
760mm*600mm*570mm
Origin
China
HS Code
9027809990
Report Range
3-18%
Autoloader Capacity
110 Tubes
Trademark
LABNOVATION
Transport Package
Carton
Specification
760mm*600mm*570mm
Origin
China
HS Code
9027809990
The Fully Automated HbA1c Analyzer-------LD-600
Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC
 
INTENDED USE
The Fully Automated HbA1c Analyzer is used to detect the percentage of HbA1c in total hemoglobin in blood samples.
PRINCIPLE
The Fully Automated HbA1c Analyzer uses high performance liquid chromatography and the stationary phase used is a weak acidic cation exchanger. The glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin and then it becomes electrically neutral. Non-glycosylated hemoglobin carries a positive charge. According to the different nature of hemoglobin, washing solution of different pH and ionic strength are used in turn. High performance liquid chromatography is used to separate several hemoglobin constituents including HbA1c.

Performance Parameters
Linearity range: linearity range of HbA1c 3%-18%; correlation coefficient: r ≥ 0.99.
Reference range: HbA1c: 4%-6% (NGSP units)
Accuracy: The relative deviation should be within ± 5%.
Reproducibility: CV ≤2.0%

Specification 
ModelLD-600Precision 
Detection principlehigh performance liquid chromatography HPLC methodWorking environment conditionstemperature: 15-30ºC
Test itemglycosylated hemoglobin HbA1Chumidity: 30-85%
Detection speed65S/testVoltage100-240VA
Detection wavelengthdual wavelength 420/600nmFrequency50/60Hz
Sample typewhole blood, pre-dilutedInstrument size760mm*600mm*570mm
Sample loading capacity110 samples can be loaded at one time, and continuous sample injection is supported
Reagent kiteluent A, eluent B, hemolytic agent, chromatography column kit

CERTIFICATE
Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLCLd-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC
COMPANY INFORMATION

LABNOVATION TECHNOLOGOES, INC was established in 2001 and has been recognized as a "National High-tech Enterprise". The registered capital (including its wholly-owned subsidiaries) is RMB 20 million, and it is one of the earliest companies exporting in vitro diagnostic reagents in China. The product sales network has covered more than 110 countries and regions around the world.
It is the first in the industry to pass the ISO9001:2008.ISO13485:2012/AC:2012 quality system TUV certification, and obtain the EU CE certification and FDA certification.
The company invests more than 10% of its sales into product research and development, hardware construction and update every year, and 85% of the company's R&D team employees have more than 5 years of industry experience.Ld-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLCLd-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLCLd-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLCLd-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLCLd-600 High-Quality Glycosylated Hemoglobin Analyzer with Anti-Mutant Protein Interference CV Value Less Than 2% by HPLC