Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor

China Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor, Find details about China Portable Fetal Monitor, Ctg Machine from Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor

Model NO.
Ysfm100
Display Update Rate
0.25second
Measurement Range
Us 30 to 240 Bpm
Resolution
1 Unit
Temperature
0-40oc
Trademark
YSENMED
Transport Package
Carton
Specification
32cm (W)*26cm (D)*8cm (H)
Origin
China
Model NO.
Ysfm100
Display Update Rate
0.25second
Measurement Range
Us 30 to 240 Bpm
Resolution
1 Unit
Temperature
0-40oc
Trademark
YSENMED
Transport Package
Carton
Specification
32cm (W)*26cm (D)*8cm (H)
Origin
China
Fetal & Maternal Monitor (10.4 inches)
YSFM100
Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor


Products
Unicare MARS K SERIES are high-tech fetal & maternal monitor, it offers a 
reliable, high-performance solution for fetal monitoring needs in the clinic 
and hospital, from pre-natal check-ups to antepartum monitoring of high-risk 
pregnancies. Mars K Series is your best partner from Antepartum through 
Intrapartum till Delivery
 
Features:
 
l Folded 10.4 inches TFT LCD high-brightness screen
l 12-crystal waterproof pulse Doppler transducer (optional), providing 
wider beam area and more homogeneous signal, thus realizing better 
performance for beside monitors than conventional transducers.
l Event Marker makes it easy to annotate perceived fetal movements (FM), 
or other events on the strip chart.
l Fetal Movement Profile(FMP) detects and automatically records gross 
fetal body movements.
l Heart rate offset mode makes it easy to visually distinguish between 
the heart rates of twins by allowing you to offset the secondary FHR + 30BPM.
l Heartbeat Coincidence recognition provides visual and audible indication 
when it detects synchronous fetal or maternal heart-rate signals, indicating 
that you may be monitoring a duplicate signal.
l Fetal heart rate alarm provides both audible and visual alerts if the heart rate
is outside of the user-defined high/low range.
l Easy-to-load Z-fold paper stacks itself neatly upon exiting the recorder, 
facilitating easy storage.
l Internal Li-on battery power or AC power from external power supply.
l Supporting TCP/IP or wireless connection to the central monitoring station
l NST Report (Fetus health report) 
 
Fetal Acoustic Stimulator(FASt)
The optional Fetal Acoustic Stimulator uses low frequency vibro-acoustic stimuli(VAS) to "wake" the fetus, increasing the efficiency of antepartum 
testing and improving retest consistency. VAS indicated with a musical note on the 
strip

Specification
Physical Specifications
Dimension and WeightDimension32cm (W)*26cm (D)*8cm (H)
Weightstandard configuration: 2.8 kg
Operation EnvironmentPower requirementsAC100-240V , 50/60Hz
Power50VA
Temperature0-40ºC
Humidity 0-93% non-condensing
Fetal/Maternal Performance Specifications
Performance SpecificationsDisplay 10.4 inches (1024×768 pixel) color TFT -LCD
IndicatorVisual on-display and integrated, alarm light, 
audible alarm
BatteryInternal rechargeable Li-ion battery power
AlarmVisual on-display and integrated, alarm light, 
audible alarm
Memory24-hours memory for fetal traces
150 groups patient data
PrinterAmerica standard/international standard   
Built-in thermal printer (paper width:110mm) 
1/2/3cm/min real-time printing speed, fast print speed (stored traces)
PaperZ-fold, thermosensitive
Record MessageID, name, age, date, time, print speed etc
CMSSupport connecting to central monitoring station 
through LAN (TCP/IP) or wireless connection
Fetal/Maternal Technical Specifications
Ultrasound (FHR)Measurement rangeUS30 to 240 bpm
ResolutionDisplay1bpm
Printer1bpm
jitter@200 bpm≤3bpm
Display update rate0.25second
Beat to bea change(max.) 
for ultrasound
28bpm
US frequency1MHz±5%Hz
TOCOMeasurement methodStrain gauge sensor element
Sensitivity  1 unit =2.5g
Resolution1 unit
Measurement range500 units
Baseline setting0, 5,10, 15, 20 can be selective 
Update rate0.25 second
Auto offset correction3 second after connecting the 
transducer
Auto zero adjust  TOCO value is set to zero negative 
following a negative Measure value 
for 5 seconds
Auto Fetal Movement (AFM)TechniquePulsed doppler ultrasound
Range    0-100%
Resolution1%
Automatic fetal movement actograph 
Manual fetal movement marker
Maternal NIBP(MNIBP)Operation modeManual/automatic/ STAT
Measurement unitmmHg / kPa  selectable
Test interval0-480 minutes
AccuracyMax.Std.deviation:8 mmHg(1.1kPa)
Max. mean Error: ±5mmHg(±0.7kPa)
Measurement rangeSystolic30 to 270 mmHg(4 to 36 kPa)  
Diastolic10 to 245 mmHg(1.5 to 32kPa)
Mean20 to 255 mmHg(2.5 to 34kPa)
Pulse rate range20-250bpm
Over-pressure protectionYes
Maternal SpO2 (MSpO2)Measurement range0%-100%
Resolution1%
Accuracy±2%
Pulse rate range accuracy±3bpm                                  


Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor
Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor
Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor
Ysfm100 Hospital Hot Sale Portable Patient Fetal Monitor