China Cummins 50kw Open Type Power Genset by Hydrogen, Find details about China 50kw Hydrogen Genset, Power Genset by Hydrogen from Cummins 50kw Open Type Power Genset by Hydrogen
1. GENERATOR DATA
Voltage Available:
50Hz: 380-400-415V/220-230-240V;
60Hz: 220-380-416-440-480V/110-208-220-240V
Any special voltage is also available as client's request
Prime Power:
Comply with GB/T2820-97(eqv.ISO8528).
Genset can run unlimitedly under certain power range.
One hour 10% over load in every 12 running hours is allowed;
Standby Power:
standby power is the limit value of maximum output for emergency use.
It is off-oil power,overloading is prohibited
2. MAIN SPECIFICATION
Model | Prime output(kw/kva) | Standby output(kw/kva) | Engine model | Alternator model |
KPC68.8-HG | 50/62.5 | 55/68.8 | 6LT8.9 | FD2C-4 |
Genset Data | Size & Weight (Open type) | 2500*1000*1500mm (1900kgs) | ||
Frequency | 60Hz | |||
Standard Features | Radiator 50OC max,fans are driven by belt, with safety guard/Ripple flex exhaust pipe, exhaust siphone, flange, muffler | |||
Voltage | 380/220V | |||
Phase & Wires | 3phase, 4wires | |||
Power Factor | COSΦ=0.8 (lagging) | |||
Battery | 24V | |||
Gas Control System | US ECI system | |||
Breaker | Schneider | |||
Engine Data | Brand & Model | Cummins 6LT8.9 | ||
Cycle | 4 stroke | |||
Air Intake Way | Turbo | |||
Governor | Electronic | |||
Cylinder | 6 | |||
Bore*Stroke (mm) | 114*145 | |||
Displacement (L) | 8.9 | |||
Average Piston Speed (m/s) | 7.8 | |||
Compression Ratio | 10:1 | |||
Combustion Mode | Lean mixture combustion | |||
Speed | 1800RPM | |||
Cooling Way | Water cooled | |||
Alternator Data | Brand & Model | Faraday FD2C-4 | ||
Alternator Power | 60KW | |||
Frequency & Speed | 60Hz, 1800RPM | |||
Phase & Voltage | 3 phases 4 wires & 380/220V | |||
System | Brushless AC Synchronous, Single bearing | |||
Insulation & Protection | H, IP23 | |||
Voltage Regulator | Standard AVR | |||
Control System | Brand & Model | DEIF AGC150 | ||
Two language interface: Chinese/English | ||||
Start or Stop Generator set manually / automatically; Open controller output can be defined as Pre-heat/Idle output. | ||||
High Coolant temperature protection; Low Oil pressure protection. Over speed protection | ||||
Over load protection; Generator over/under frequency protection: Generator over/under/unbalance voltage protection |
3. PRODUCT FEATURES
(1).Full control panel with power indicator light and oil light.
(2).Emergency shutdown for low oil pressure and high water temperature.
(3).Large fuel tank ensure continuous running.
(4).Low noise & vibration.
(5).Compact structure.
(6).Reliable performance.
(7).Easy for installation and maintenance.
(8).50Hz and 60Hz both are available for choice