Transformer Oil Tan Delta Meter/ Insulating Oil Power Factor Tester

China Transformer Oil Tan Delta Meter/ Insulating Oil Power Factor Tester, Find details about China Dielectric Tester, Test Equipment from Transformer Oil Tan Delta Meter/ Insulating Oil Power Factor Tester

Model NO.
SYNY-0021JS
Resolution
Tgδ: 0.001%;Cx: 0.001PF
Accuracy
△tgδ:±(Reading*1.0%+0.040%)
CVT Ratio Range
10~10000
CVT Ratio Precision
0.1%
CVT Ratio Resolution
0.01
Memory Size
200 Sets Support U Disk Data Storage
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000
Model NO.
SYNY-0021JS
Resolution
Tgδ: 0.001%;Cx: 0.001PF
Accuracy
△tgδ:±(Reading*1.0%+0.040%)
CVT Ratio Range
10~10000
CVT Ratio Precision
0.1%
CVT Ratio Resolution
0.01
Memory Size
200 Sets Support U Disk Data Storage
Transport Package
Wooden Case
Origin
Shanghai, China
HS Code
9030339000

Application

Transformer automatic dielectric loss tester is a high-precision dielectric loss tangent value and capacitance test instrument for various high-voltage power equipment in power plant, substation and other fields or laboratories. The instrument is an integrated structure with built-in dielectric loss test bridge, variable frequency voltage-regulating power supply, booster transformer and SF6 high stability standard capacitor. The test high voltage source is generated by the inverter inside the instrument and is used for the test of the test object after the transformer is boosted. Frequency can be changed into 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz, digital notch wave technology is adopted to avoid interference of power frequency electric field on the test.

Features

1.Super LCD display
Operation is simple. The instrument is equipped with a high quality full-touch LCD screen and a super-large full-touch operation interface. Each process is very clear and clear. It is an ideal intelligent dielectric loss measuring device at present.
2Mass storage data
The instrument is equipped with a calendar chip and a large-capacity memory, which can store 200 sets of data. The test results can be saved in chronological order, the history can be viewed at any time, and the output can be printed.
3.Scientific and advanced data management
Instrument data can be exported through U disk, and can be viewed and managed on any PC through our company's special software.
4.Multiple test modes
The instrument can be tested by internal high voltage, external high voltage, internal standard, external standard, positive wire method, negative wire method, self-excitation method and other methods.High voltage (greater than 10kV) dielectric loss can be achieved under external standard external high voltage.
5.CVT test by one step at a time
The instrument can also test the dielectric loss and capacitance of CVT (capacitive voltage transformer) C1 and C2, realizing the simultaneous test of C1 and C2.The instrument can also test the CVT ratio and voltage Angle difference.
6.Measuring CVT without removing high voltage lead
The instrument can correctly measure the dielectric loss and capacitance of CVT without removing the high voltage lead of CVT.
7.CVT negative wire shielding method measuring C0
The instrument can measure the dielectric loss and capacitance of C0 at the upper end of CVT by negative wire shielding method.
8.High speed sampling signal
The inverter and sampling circuit inside the instrument are all controlled by digitalization, and the output voltage is continuously adjustable.
9.Multiple protection is safe and reliable
The instrument has multiple protection measures such as input voltage fluctuation, high voltage current, output short circuit, power supply fault, over-voltage, over-current, temperature and so on, which ensures the safety and reliability of the instrument.The instrument also has the function of grounding detection to ensure that ungrounded devices are not allowed to boost voltage.

Detailed Photos

Transformer Oil Tan Delta Meter/ Insulating Oil Power Factor Tester

Technical specification

1Working condition-15ºC~40ºCRH<80%
2Anti-interference principlevariable-frequency method
3Power supplyAC 220V±10%Permissible generator
4High Voltage Output0.5KV~10KVEvery other 0.1kV
Accuracy2%
Max current      200mA
Capacity2000VA
5Self-exited power supplyAC 0V~50V/15A50HZ,60HZ single frequency
45HZ/55HZ
47.5HZ/52.5HZ
55HZ/65HZ   57.5HZ/62.5HZ
Automatic double frequency
6Resolutiontgδ: 0.001%Cx: 0.001pF
7Accuracy△tgδ:±(reading*1.0%+0.040%)
  △C x :±(reading*1.0%+1.00PF)
8Measurement rangetgδunrestricted
C x15pF < Cx < 300nF
10KVCx < 60  nF
 5KVCx < 150 nF
  1KVCx < 300 nF
CVT testCx < 300 nF
9CVT ratio range10~10000
CVT ratio precision0.1%
CVT ratio resolution0.01
10Size of host machine (mm)350(L)×270(W)×270(H)
Size of accessory case (mm)350(L)×270(W)×160(H)
11Memory size200 sets   support U disk data storage
12Weight of host machine 22.75Kg
Weight of accessory case 5.25Kg