Nitrous Oxide Sedation System S8800c with Cheap Price

China Nitrous Oxide Sedation System S8800c with Cheap Price, Find details about China Anesthesia Machine, Medical Device from Nitrous Oxide Sedation System S8800c with Cheap Price

Model NO.
S8800C
OEM
Yes
Hanger
Yes
Oscillogram
P-T
Trademark
Superstar
Transport Package
Wooden Case
Specification
L 570*W 780*H 1620mm, GW: 90KG; NW: 43KG
Origin
Nanjing, China
HS Code
90189070
Model NO.
S8800C
OEM
Yes
Hanger
Yes
Oscillogram
P-T
Trademark
Superstar
Transport Package
Wooden Case
Specification
L 570*W 780*H 1620mm, GW: 90KG; NW: 43KG
Origin
Nanjing, China
HS Code
90189070
Nitrous Oxide Sedation System S8800C with Cheap price
 
7" TFT LCD touch screen displays the Ventilation parameters,Alarming information and Waveform.
Multiple paramenters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
Multiple Ventilation mode,suitable for different clinical need
With lots of alarm, reminding and protection functions

Ventilation mode: Continuous gas supply or On-demand gas supply , Rapid oxygen supply, MANUAL
On-demand gas: 0-30L
Manual ventilation:0-30L/min
Rapid oxygen flow: 25L/min-75L/min
Airway pressure:25L/min-75L/min
Oscillogram: P-T

Gas supply

  1. Gas source                      O2(For medical use)
                                                                   N2O(For medical use)
  1. Input pressure range            280 kPa~600 kPa
  2. Negative pressure gas source       flow 75 L/min
(when equipped with Transfer and receiving system of anaesthetic gas scavenging system)

Power supply

  1. Voltage                       100-240 V~
  2. Frequency                         50 HZ/60 HZ
  3. Input power                60 VA
  4. Internal battery                               DC12V    4Ah
  1. Fuse                                                      
--Main power          T2AH 250V
--Internal power            T4AH 250V
 

Ventilation parameters

  1. O2 concentration       
--Adjusting range             30 %~100 %(v/v)
--Allowable error             ± 15 %, and minimum O2 concentration 30 %
  1. N2O concentration                   
--Adjusting range             0 %~70 %(v/v)
--Allowable error                        ± 15 % or ± 3 %(v/v), whichever is the
greater, and maximum  N2O concentration 70 %
  1. As required flow                    
--Adjusting range            0 L/min ~ 30L/min
  1. Pressure trigger             
--Adjusting range             -1 cmH2O~ -10 cmH2O
--Allowable error              ±(1 cmH2O +10 % setting valve)
  1. Gas supply time             
--Adjusting range             1 s ~ 6 s
--Allowable error              ± 20 %
  1. Output gas flow from manual ventilation       
--Adjusting range                          0 L/min ~ 30 L/min
  1. Flow rate of oxygen flush valve         25 L/min ~ 75 L/min
  2. Maximum gross flow                          ≥ 60 L/min

Ventilation parameter Monitoring

  1. O2 concentration              
--Monitoring range                 30 % ~ 100 %
--Allowable error                    ±(2.5 % v/v+2.5 % concentration level)
  1. Airway pressure
--Monitoring range                 0 cmH2O ~ 60 cmH2O
--Allowable error                    ±( 2%full scale + 4%actual reading )
  1. Continuous flow and as required flow
--Monitoring range                 0 L/min ~ 30 L/min
--Allowable error                         >3.0 l/min:± 20 %, 3.0 l/min: ± 0.6 l/min
  1. Waveform display:

--Time- airway pressure

Nitrous Oxide Sedation System S8800c with Cheap Price


Nitrous Oxide Sedation System S8800c with Cheap Price
Nitrous Oxide Sedation System S8800c with Cheap Price


Nitrous Oxide Sedation System S8800c with Cheap PriceNitrous Oxide Sedation System S8800c with Cheap Price