S8800A Nitrous Oxide Sedation System

China S8800A Nitrous Oxide Sedation System, Find details about China Nitrous Oxide, Sedation System from S8800A Nitrous Oxide Sedation System

Model NO.
S8800A
Anesthesia
Semi Open Suction
Type of Operating Light
Double Operating Light
Trademark
Supersatar
Transport Package
Wooden Package
Origin
China
HS Code
9018499000
Model NO.
S8800A
Anesthesia
Semi Open Suction
Type of Operating Light
Double Operating Light
Trademark
Supersatar
Transport Package
Wooden Package
Origin
China
HS Code
9018499000

S8800A Nitrous Oxide Sedation SystemS8800A Nitrous Oxide Sedation SystemS8800A Nitrous Oxide Sedation SystemS8800A Nitrous Oxide Sedation SystemS8800A Nitrous Oxide Sedation System

Main technical specification of S8800A

Gas supply

  1. Gas source      O2(For medical use)
                                                                   N2O(For medical use)
Input pressure range    280 kPa~600 kPa
Negative pressure gas source       flow ≥75 L/min
(when equipped with Transfer and receiving system of anaesthetic gas scavenging system)
 

Power supply

  1. Voltage 100-240 V~
  2. Frequency 50 HZ/60 HZ
  3. Input power 60 VA
  4. Internal battery                               DC12V    4Ah
  1. Fuse
--Main power T2AH 250V
--Internal power T4AH 250V
 

Ventilation parameters

O2 concentration
--Adjusting range    30 %~100 %(v/v)
--Allowable error   ± 15 %, and minimum O2 concentration ≥30 %
N2O concentration
--Adjusting range    0 %~70 %(v/v)
--Allowable error     ± 15 % or ± 3 %(v/v), whichever is the
greater, and maximum  N2O concentration ≤70 %
Continuous flow     
--Adjusting range   0 L/min ~ 30 L/min
As required flow     
--Adjusting range   0 L/min ~ 30L/min
Pressure trigger     
--Adjusting range    -1 cmH2O~ -10 cmH2O
--Allowable error    ±(1 cmH2O +10 % setting valve)
Gas supply time     
--Adjusting range    1 s ~ 6 s
--Allowable error    ± 20 %
Output gas flow from manual ventilation
--Adjusting range                          0 L/min ~ 30 L/min
Flow rate of oxygen flush valve         25 L/min ~ 75 L/min
Maximum gross flow                           60 L/min 

Ventilation parameter Monitoring 

O2 concentration
--Monitoring range          30 % ~ 100 %
--Allowable error          ±(2.5 % v/v+2.5 % concentration level)
Airway pressure
--Monitoring range          0 cmH2O ~ 60 cmH2O
--Allowable error          ±( 2%full scale + 4%actual reading )
Continuous flow and as required flow
--Monitoring range          0 L/min ~ 30 L/min
--Allowable error                      >3.0 l/min:± 20 %, ≤3.0 l/min: ± 0.6 l/min
Waveform display:
--Time- airway pressure
 

Alarm, hint and protection 

  1. Mains power failure alarm
When the power is supplied by AC, the power state indication place will display the signal of "" or "".
When the power is changed from AC to back-up battery , there is sound indication from the machine, and the power state indication place will display the signal of " ".
  1. Alarm of low voltage of back-up battery
When the voltage of back-up battery is low, the power state indication place will display the signal of "", and there will be a sound alarm.
Alarm lasting time: >60 s
!  Warning:
If battery power fails during operation, please switch off the machine and do manual ventilation to the patient.
  1. Alarm of low pressure for input N2O
When the pressure of input N2O is under (180 ± 20) kPa, there will be a sound alarm and display of Low pressure for input N2O.
  1. Alarm of low pressure for input O2
When the pressure of input O2 is under (180 ± 20) kPa, there will be a sound alarm and display of Low pressure for input O2.
  1. High O2 alarm
When the monitoring value of O2 concentration over the upper limit of O2, there will be a sound alarm and display of O2 high.
--Setting range 31 % ~ 100 %
  1. Low O2 alarm
When the monitoring value of O2 concentration under low limit of O2 concentration, there will be a sound alarm and display of O2 low.
--Setting range 30 % ~ 99 %
  1. High Ppeak alarm
When the monitoring value over the upper limit of Ppeak, there will be a sound alarm and display of High Paw pressure.
--Setting range 5 cmH2O ~ 60 cmH2O
  1. Pressure limit
When the airway pressure is over the set pressure limit, there will be a sound alarm and display of High Paw pressure, and he pressure will be limited under the set value.
--Allowable error                                                 ±5 cmH2O
  1. Protection for insufficient O2 supply    
      When O2 supply pressure is lower than 200 kPa,  NO2 shutoff valve will shut off NO2 supply.                                 
  1. Maximum limit pressure
The safety valve will be on when the Paw is over the set maximum limit pressure.
--Maximum limit pressure                                         60 cmH2O±5 cmH2O
  1. Emergency air intake valve
Emergency air intake valve will be on when the Paw is during -2cmH2O ~ -8 cmH2O.  
  1. Gas supply safety valve
Gas supply safety valve will exhaust when O2 or N2O supply pressure is over (750 ± 100) kPa.
  1. Mute
When an alarm occurs, the alarm sound may be muted by pressing AUDIO PAUSED key, but the alarm indication will display on the screen, unless the problem is solved.
--Muting time <120 s