Blue Fin Copper Tube Water Ceiling Floor Fan Coil Unit
1. Ceiling mounted floor standing fan coil brief introductionProduct name | Ceiling floor fan coils |
Cooling capacity | 2.7~12.6KW |
Heating capacity | 4.05~18.9KW |
DB/WB | 27ºC / 19.5ºC |
Model | EST300CF2~EST1400CF2 |
Airflow | 300-1400 CFM |
Fan type | Centrifugal fan |
Funtion | Air Conditioner Terminal Unit |
Application | Commercial buildings,Hospital,Super market etc. |
2. Ceiling mounted floor standing fan coil unit main components
(1) Fan
(2) Motor
(3) Casing
(4) Heat exchanger
(5)Water tray
(6) Washable filter
(7) Remote controller
3. Ceiling mounted exposed floor standing fan coil features
(1)Classical elegant design
(2)Can be installed by ceiling mounted, floor standing or wall mounted
(3)Remote controller is standard and wire controller is optional
(4)Wide air discharge range, can discharge air to high area
(5)Auto swing and quiet running
(6)Stainless steel hose can be installed as inlet outlet water connection (optional)
(7)Easily interfaced with most widely used Mod-Bus and proprietary supervisory system based on mod bus protocol.
(8)Water valve inside is optional, save labor installation cost
(9)4 pipe system is optional 4. Eurostars Fan coil unit series
1 | Ceiling concealed fan coil unit |
2 | High ESP ducted fan coil unit |
3 | Universal concealed fan coil unit |
4 | Floor standing exposed fan coil unit |
5 | Ultra thin exposed fan coil unit |
6 | Ceiling exposed fan coil unit |
7 | Ceiling cassette fan coil unit |
8 | Ceiling exposed & floor standing fan coil unit |
9 | Wall mounted fan coil unit |
5. Ceiling mounted floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system) |
Model EST~ | 300CF2 | 400CF2 | 500CF2 | 600CF2 | 800CF2 | 1000CF2 | 1200CF2 | 1400CF2 |
Air flow (m3/h) | High | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
Medium | 420 | 560 | 770 | 910 | 1210 | 1450 | 1850 | 2150 |
Low | 340 | 480 | 610 | 820 | 1100 | 1380 | 1600 | 2000 |
Cooling capacity | TH | H | W | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
BTU | 9215 | 12287 | 15359 | 18430 | 24574 | 30717 | 36860 | 43004 |
SH | W | 1990 | 2730 | 3174 | 4261 | 5385 | 6746 | 8109 | 9062 |
BTU | 6792 | 9317 | 10833 | 14543 | 18379 | 23024 | 27676 | 30929 |
TH | M | W | 2485 | 3030 | 3752 | 4467 | 6499 | 7926 | 9389 | 10605 |
BTU | 8481 | 10341 | 12806 | 15246 | 22181 | 27051 | 32045 | 36195 |
SH | W | 1570 | 2015 | 2450 | 3070 | 4278 | 5447 | 6669 | 7262 |
BTU | 5358 | 6877 | 8362 | 10478 | 14601 | 18591 | 22761 | 24785 |
TH | L | W | 2078 | 2504 | 2950 | 3831 | 5660 | 7295 | 8619 | 8989 |
BTU | 7092 | 8546 | 10068 | 13075 | 19318 | 24898 | 29417 | 30679 |
SH | W | 1212 | 1545 | 1844 | 2397 | 3317 | 4460 | 5300 | 5555 |
BTU | 4137 | 5273 | 6294 | 8181 | 11321 | 15222 | 18089 | 18959 |
Heating capacity | H | W | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
BTU/h | 13823 | 18430 | 23038 | 27645 | 36860 | 46076 | 55291 | 64506 |
M | W | 2792 | 3970 | 4941 | 5740 | 7987 | 10557 | 13101 | 14011 |
BTU/h | 9529 | 13550 | 16864 | 19591 | 27260 | 36031 | 44714 | 47820 |
L | W | 1788 | 2800 | 3533 | 3907 | 5464 | 7048 | 8714 | 9778 |
BTU/h | 6102 | 9556 | 12058 | 13335 | 18649 | 24055 | 29741 | 33372 |
Ceiling Exposed/Floor Mounted Fan Coil Unit (4 pipe system) |
Model EST~ | 300CF4 | 400CF4 | 500CF4 | 600CF4 | 800CF4 | 1000CF4 | 1200CF4 | 1400CF4 |
Air flow (m3/h) | High | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
Medium | 420 | 560 | 770 | 910 | 1210 | 1450 | 1850 | 2150 |
Low | 340 | 480 | 610 | 820 | 1100 | 1380 | 1600 | 2000 |
Cooling capacity | TH | H | W | 2025 | 2700 | 3375 | 4050 | 5400 | 6750 | 8100 | 9450 |
BTU | 6911 | 9215 | 11519 | 13823 | 18430 | 23038 | 27645 | 32253 |
SH | W | 1532 | 2102 | 2445 | 3281 | 4146 | 5194 | 6245 | 6978 |
BTU | 5229 | 7174 | 8345 | 11198 | 14150 | 17727 | 21314 | 23816 |
TH | M | W | 1864 | 2273 | 2814 | 3350 | 4874 | 5945 | 7042 | 7954 |
BTU | 6362 | 7758 | 9604 | 11434 | 16635 | 20290 | 24034 | 27147 |
SH | W | 1210 | 1552 | 1887 | 2365 | 3295 | 4195 | 5135 | 5592 |
BTU | 4130 | 5297 | 6440 | 8072 | 11246 | 14318 | 17526 | 19085 |
TH | L | W | 1559 | 1878 | 2213 | 2873 | 4245 | 5470 | 6465 | 6742 |
BTU | 5321 | 6410 | 7553 | 9806 | 14488 | 18669 | 22065 | 23010 |
SH | W | 933 | 1190 | 1420 | 1845 | 2555 | 3435 | 4081 | 4277 |
BTU | 3184 | 4061 | 4846 | 6297 | 8720 | 11724 | 13928 | 14597 |
Heating capacity | H | W | 1620 | 2160 | 2701 | 3240 | 4320 | 5400 | 6480 | 7560 |
BTU/h | 5529 | 7372 | 9219 | 11058 | 14744 | 18430 | 22116 | 25802 |
M | W | 1115 | 1588 | 1976 | 2296 | 3195 | 4223 | 5240 | 5604 |
BTU/h | 3805 | 5420 | 6744 | 7836 | 10905 | 14413 | 17884 | 19126 |
L | W | 715 | 1120 | 1413 | 1563 | 2186 | 2819 | 3486 | 3911 |
BTU/h | 2440 | 3823 | 4823 | 5335 | 7461 | 9621 | 11898 | 13348 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ceiling floor fan coil unit construction parts
7. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
8. Our warranty, technical support and failure claim proceduresand
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date.
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c. Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.
9. Our OEM and ODM service:
EUROSTARS was established in 2006, has a professional technical team to research and develope HVAC products. We offer OEM/ODM service to our clients.
Now EUROSTARS collaborate with our clients in the following ways:
(1)Produce EUROSTARS standard products under clients' brand.
(2)Modify the products to satisfy clients' personalized requirements.
(3)If clients have their own idea and design of the products, EUROSTARS can actualize it and modify it make it easy for mass production.
(4)Based on strong capability of research and development, EUROSTARS can work together with clients to design and produce a totally new products.
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..