FTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint Closure

China FTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint Closure, Find details about China Fiber Closure, Fiber Closure with Splitter from FTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint Closure

Model NO.
fiber closure
Warranty Time
2 Years
Models
FTTH-S305
Product Port
6 Cable Ports+16 Drop Cable Ports
Trademark
OEM
Transport Package
Box
Origin
Made in China
Model NO.
fiber closure
Warranty Time
2 Years
Models
FTTH-S305
Product Port
6 Cable Ports+16 Drop Cable Ports
Trademark
OEM
Transport Package
Box
Origin
Made in China

Fttx Closure 16cores with snaplock waterproff Fiber Closure with splitter and distribute Joint Closure


Products Description

S305 Fiber Optical Splice Closure
Horizontal Closure provide space and protection for fiber optic cable splicing and joint. They can be mounted aerial, buried, or for underground applications. They are designed to be waterproof and dust proof. They can be used in temperature ranging from -40°C to 85°C, can accommodate 70 to 106 kpa pressure and the case are usually made of high tensile construction plastic.
Product Name
FAT-16A Inline type fiber optic splice closure
Weight
1.65kg
package
10pcs/carton
carton size
62*31*42 cm
Material
PP+fiberglass
Cable Ports
6 cable ports+16 drop cable ports
Core capacity per tray
24 cores  per tray
Max. Capacity of Trays
1 trays
Diameter of in/out ports 
20mm&11mm
Installation 
Aerial, and Wall-mounted

 

Product Show

FTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint ClosureFTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint ClosureFTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint ClosureFTTX Closure 16cores with Snaplock Waterproff Fiber Closure with Splitter and Distribute Joint Closure

 

 

 

 

Characteristics
Value/Performance
Methods and Conditions
Mechanical
 
 
Air Tightness
No air bubble seen
Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa.
Remains100kPa±5kPa
Measure the internal pressure 24 hours later
 
Air Tightness after re-installation
No air bubble seen and pressure remains unchanged
Do re-entry and re-installation 3 times and repeat above Air Tightness Tests.
 
Axial Pulling
 
Pressure remains unchanged
Pulling force: 1000N
 Time: 1min
Internal air pressure: 60kPa±5kPa
 
Compression
 
Pressure remains unchanged
Applied pressure: 2000N/100mm
Time: 1min
Internal air pressure: 60kPa±5kPa
 
Impact
 
Pressure remains unchanged
Impact energy: 16N.m
No. of impacts: 3
Internal air pressure: 60±5kPa
 
Bending
 
Pressure remains unchanged
Bending angle±45°(in two opposite directions)
Tension: 150N
No. of bending: 10
Internal air pressure: 60kPa±5kPa
 
Twisting
 
Pressure remains unchanged
Twisting angle: ±90°
Torque: 50N
No. of twisting: 10
Internal air pressure: 60kPa±5kPa
Thermal
 
Temperature Cycling
 
Pressure drop ≤5kPa
Cycling range: -40 ~ +60°C
Cycling time: 2hrs at -40°C, then 2hrs at +60°C
No. of cycling: 3
Internal air pressure: 60kPa±5kPa
Electrical
 
 
 
 
Insulation
Resistance between
metal parts:2.0x105MΩ
 
Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water.
Resistance between each metal part and ground:2.0x105MΩ
 
High Voltage
 
No voltage break-downs and sparks
 
Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside