China Enclosed Conductor Rail Unipole Insulated Conductor Seamless High Tro Reel System, Find details about China Conductor Rail, Conductor Bar from Enclosed Conductor Rail Unipole Insulated Conductor Seamless High Tro Reel System
HFP52 series Enclosed Conductor Rail (AKAPP) | |||||||
Model | Pole No. | Cross section (mm2 ) | Max. current (A) | Leakage-distance (mm) | Max. voltage (V) | Resistance (Ω) | Weight (kg) |
HFP52-4-10/50 | 4 | 10 | 50 | 55 | 600 | 1.656 | 2.05 |
HFP52-7-10/50 | 7 | 10 | 50 | 15 | 600 | 1.656 | 2.32 |
HFP52-4-15/80 | 4 | 15 | 80 | 55 | 600 | 1.137 | 2.32 |
HFP52-7-15/80 | 7 | 15 | 80 | 15 | 600 | 1.137 | 2.71 |
HFP52-4-20/100 | 4 | 20 | 100 | 55 | 600 | 1.011 | 2.47 |
HFP52-7-20/100 | 7 | 20 | 100 | 15 | 600 | 1.011 | 2.99 |
HFP52-4-25/120 | 4 | 25 | 120 | 55 | 600 | 0.713 | 2.63 |
HFP52-7-25/120 | 7 | 25 | 120 | 15 | 600 | 0.713 | 3.27 |
HFP52-4-35/140 | 4 | 35 | 140 | 55 | 600 | 0.522 | 2.97 |
HFP52-7-35/140 | 7 | 35 | 140 | 15 | 600 | 0.522 | 3.87 |
HFP56 series Enclosed Conductor Rail (VAHLE's KBH) | |||||||
Model | Pole No. | Cross section (mm2 ) | Max. current (A) | Leakage-distance (mm) | Max. voltage (V) | Resistance (Ω) | Weight (kg) |
HFP56-4-8/35 | 4 | 8 | 35 | 35 | 600 | 1.944 | 2.09 |
HFP56-4-10/50 | 4 | 10 | 50 | 35 | 600 | 1.656 | 2.16 |
HFP56-4-12/65 | 4 | 12 | 65 | 35 | 600 | 1.321 | 2.23 |
HFP56-4-15/80 | 4 | 15 | 80 | 35 | 600 | 1.137 | 2.3 |
HFP56-4-20/100 | 4 | 20 | 100 | 33 | 600 | 1.011 | 2.43 |
HFP56-4-25/120 | 4 | 25 | 120 | 33 | 600 | 0.713 | 2.56 |
HFP56-4-35/140 | 4 | 35 | 140 | 33 | 600 | 0.522 | 2.95 |
HFP56-4-50/170 | 4 | 50 | 170 | 33 | 600 | 0.337 | 3.25 |
HFP56-4-70/210 | 4 | 70 | 210 | 33 | 600 | 0.265 | 3.85 |
HFP56-4-80/240 | 4 | 80 | 240 | 30 | 600 | 0.223 | 4.16 |
HFP95 series Enclosed Conductor Rail | |||||||
Model | Pole No. | Cross section (mm2) | Max. current (A) | Leakage-distance (mm) | Max. voltage (V) | Resistance (Ω) | Weight (kg) |
HFP95-5-10/50 | 5 | 10 | 50 | 20 | 660 | 1.656 | 3.2 |
HFP95-5-15/80 | 5 | 15 | 80 | 20 | 660 | 1.193 | 3.28 |
HFP95-5-20/100 | 5 | 20 | 100 | 20 | 660 | 1.011 | 3.51 |
HFP95-6-10/50 | 6 | 10 | 50 | 20 | 660 | 1.656 | 3.16 |
HFP95-6-15/80 | 6 | 15 | 80 | 20 | 660 | 1.193 | 3.41 |
HFP95-6-20/100 | 6 | 20 | 100 | 20 | 660 | 1.011 | 3.68 |
HFP95-7-10/50 | 7 | 10 | 50 | 20 | 660 | 1.656 | 3.25 |
HFP95-7-15/80 | 7 | 15 | 80 | 20 | 660 | 1.193 | 3.56 |
HFP95-7-20/100 | 7 | 20 | 100 | 20 | 660 | 1.011 | 3.88 |
HFP95-8-10/50 | 8 | 10 | 50 | 20 | 660 | 1.656 | 3.34 |
HFP95-8-15/80 | 8 | 15 | 80 | 20 | 660 | 1.193 | 3.7 |
HFP95-8-20/100 | 8 | 20 | 100 | 20 | 660 | 1.011 | 4.04 |
HFP95-9-10/50 | 9 | 10 | 50 | 20 | 660 | 1.656 | 3.42 |
HFP95-9-15/80 | 9 | 15 | 80 | 20 | 660 | 1.193 | 3.77 |
HFP95-9-20/100 | 9 | 20 | 100 | 20 | 660 | 1.011 | 4.24 |
HFP95-10-10/50 | 10 | 10 | 50 | 20 | 660 | 1.656 | 3.54 |
HFP95-10-15/80 | 10 | 15 | 80 | 20 | 660 | 1.193 | 3.98 |
HFP95-10-20/100 | 10 | 20 | 100 | 20 | 660 | 1.011 | 5.21 |
Unipole Conductor Rail system NSP-H Series | |||||
Conductor rail | Aluminium | Copper | |||
Type | H19 | H24 | H32 | H24 | H32 |
Nominal current at 100% DC and 35°C[A] | 150 | 250 - 300 | 320 - 1250 | 500 - 800 | 800 - 1600 |
D.C.resistance at 35°C [Ω/km] | 0.376 | 0.2030.187 | 0.1530.046 | 0.1160.067 | 0.0670.039 |
Impendance at 35°C [Ω/km] | 0.376 | 0.2090.195 | 0.1550.048 | 0.1180.069 | 0.0690.04 |
Support spacing [m] | 1.8 | 1.5 | 1.8 | 1.5 | 1.8 |
Rail length [m] | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
Housing length [m] | 3.88/5.88 | 3.88/5.88 | 3.83/5.83 | 3.88/5.88 | 3.83/5.83 |
Max.voltage [V] | 660V | Dielectric strength[KV/mm] | 30-40 | ||
Travelling speed | ≤ 600 m/min | Standard | GB7251.2-2006 | ||
Expansion joint | only required when total length ≥ 200m | ||||
Flame retardant | Class B1-no flaming particles,self-extinguishing | ||||
Permissible ambient temperature | Standard insulation -20C- +70C High temperature insulation -10C- +115C |
Type | Conductor Rail | Cross section (mm2) | Nominal current (A) | Leakage-distance (mm) | Resistance (Ω/km) | Weight (kg/m) |
NSP-H24-160/250 | Aluminium | 160 | 250 | 45 or 80 | 0.203 | 0.63 |
NSP-H24-180/300 | Aluminium | 180 | 300 | 45 or 80 | 0.187 | 0.71 |
Type | Conductor Rail | Cross section (mm2) | Nominal current (A) | Leakage-distance (mm) | Resistance (Ω/km) | Weight (kg/m) |
NSP-H32-230/320 | Aluminium | 230 | 320 | 80 | 0.153 | 0.96 |
NSP-H32-285/500 | Aluminium | 285 | 500 | 80 | 0.116 | 1.13 |
NSP-H32-360/630 | Aluminium | 360 | 630 | 80 | 0.087 | 1.38 |
NSP-H32-420/800 | Aluminium | 450 | 800 | 80 | 0.067 | 1.5 |
NSP-H32-550/1000 | Aluminium | 550 | 1000 | 80 | 0.058 | 1.83 |
NSP-H32-600/1250 | Aluminium | 600 | 1250 | 80 | 0.046 | 2.01 |
Type | Poles | Conductor Cross Section (mm²) | Max.Current (A) | Weight (kg/m) |
HTR-3-10/50A | 3 | 3x10 | 50A | 0.57 |
HTR-3-15/80A | 3 | 3x15 | 80A | 0.73 |
HTR-3-20/100A | 3 | 3x20 | 100A | 0.85 |
HTR-3-25/120A | 3 | 3x25 | 120A | 0.98 |
HTR-3-35/140A | 3 | 3x35 | 140A | 1.27 |
Type | Poles | Conductor Cross Section (mm²) | Max.Current (A) | Weight (kg/m) |
HTR-4-10/50A | 4 | 3x10+1x10 | 50A | 0.75 |
HTR-4-15/80A | 4 | 3x15+1x10 | 80A | 0.90 |
HTR-4-20/100A | 4 | 3x20+1x10 | 100A | 1.05 |
HTR-4-25/120A | 4 | 3x25+1x10 | 120A | 1.15 |
HTR-4-35/140A | 4 | 3x35+1x10 | 140A | 1.43 |
Type | Poles | Conductor Cross Section (mm²) | Max.Current (A) | Weight (kg/m) |
HTR-6-10/50A | 6 | 6x10 | 50A | 1.10 |
HTR-6-15/80A | 6 | 6x15 | 80A | 1.50 |