1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

China 1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232, Find details about China Solar Inverter, Solar Power Inverter 5kVA from 1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Model NO.
SSP3118C1 1-5KVA
Power Source
Solar Power
Circuit Topologies
Half-Bridge Type
Nature of Wave String
Sine Wave Inverter
Product Name
off-Grid Solar Power Inverter
High Frequency
Pure Sine Wave Solar Inverter
Solar Controller
60A PWM
DC Voltage
12V/24V/48V
Charging Priority
PV/AC/PV&AC (Optional)
Output Priority
PV/AC/Inverter
Frequency
50/60Hz(Auto Sensing)
Selectable Voltage Range
170-280VAC;90-280VAC
Nominal Voltage
230VAC
Application
Fridge,Air-Conditional,TV,Computer
Trademark
SOROTEC
Transport Package
Standard Carton and Wooden Pallet
Specification
CE
Origin
China Mainland
HS Code
8504403090
Model NO.
SSP3118C1 1-5KVA
Power Source
Solar Power
Circuit Topologies
Half-Bridge Type
Nature of Wave String
Sine Wave Inverter
Product Name
off-Grid Solar Power Inverter
High Frequency
Pure Sine Wave Solar Inverter
Solar Controller
60A PWM
DC Voltage
12V/24V/48V
Charging Priority
PV/AC/PV&AC (Optional)
Output Priority
PV/AC/Inverter
Frequency
50/60Hz(Auto Sensing)
Selectable Voltage Range
170-280VAC;90-280VAC
Nominal Voltage
230VAC
Application
Fridge,Air-Conditional,TV,Computer
Trademark
SOROTEC
Transport Package
Standard Carton and Wooden Pallet
Specification
CE
Origin
China Mainland
HS Code
8504403090
1KVA-5KVA Hybrid Solar Power Inverter Built-in PWM with RS232

SOROTEC SSP3118C1  (1000va-5000va) Series is a multi-function  Off-grid type Solar Power Inverter,which built-in 50Amp PWM Solar Charge Controller.Adopts advanced Parallel technology can achieve max 6pcs (4kva/5kva) Solar Inverter for capacity expansion ,and also can support 3 Phase input and output by parallel operation. it support Various Charging Priority Modes and Output Priorities . High Frequency with half-bridge design,Pure sine wave  can provide reliable long backup time ac power supply for home and office equipment such as:Fridge,Air-conditional,TV,Computer .etc

Key Features:
1.Built-in PWM/MPPT solar controller
2.Pure sine wave inverter
3.Cold start function
4.Auto restart while AC is recovering
5.Overload and short circuit protection
6.Optional remote panel available
7.Selectable charging current based on applications
8.Configurable AC/Solar input priority via LCD setting
9.Compatible to mains voltage or generator power
10.Smart battery charger design for optimized battery performance
11.Parallel operation with up to 6 units only available for 4KVA/5KVA
12.Selectable input voltage range for home appliances and personal computers
1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Full Protection:

Protection for low battery voltage, over load, output short circuit and over- temperature Restrain surge interference, eliminate noise, protection for thunder striking, provide the reliable power to the home appliances.

Applications:

Supply the reliable long back up time power for the home appliances and office appliances solar power systems etc.
1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Product Parameter of SOROTEC SSP3118C1 1000-5000VA  Hybrid Solar Power Inverter

MODELC1 1K-1250C1 2K-2450C1 3K-2450C1 4K-4850C1 5K-4850
Rated Power1000VA/800W2000VA/1600W3000VA/2400W4000VA/3200W5000VA/4000W
INPUT
Voltage230 VAC
Selectable Voltage Range170-280 VAC (For Personal Computers)  90-280 VAC (For Home  Appliances)
Frequency Range50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)230VAC ± 5 %
Surge Power2000VA4000VA6000VA8000VA10000VA
Efficiency (Peak)90%93%
Transfer Time10 ms (For Personal Computers) 20 ms (For Home Appliances)
WaveformPure sine wave
BATTERY
Battery Voltage12 VDC24 VDC48 VDC
Floating Charge  Voltage13.5 VDC27 VDC54 VDC
Overcharge Protection15.5 VDC31 VDC60 VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage50VDC60VDC105VDC
Standby Power Consumption1 W2 W2W
Maxmum Solar Charge Current50A50A50 A
Maximum AC Charge Current20 A30 A60 A
Maximum Charge Current50 A50 A110 A
PHYSICAL
Dimension, D x W x H (mm)100 x 240 x 318105x 272 x 355120 x 295 x 468
Net Weight (kgs)56.46.99.8
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature0°C - 55°C
Storage Temperature-15°C - 60°C


Product Show:

1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Introduction of Company 
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards. 

  1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Trade Show:
1kVA-5kVA Hybrid Solar Power Inverter Built-in PWM with RS232

Why Choose US?
1,QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC. 
2,Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world. 


FAQ
1.How to choose suitable inverter?

 
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
 
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
 
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power.

  .....................................................................................................................................................................................................................................
 
2.How do I choose the size of the inverter?
 
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
 
Notice:
 
Resistive load: you can choose the same power as the load. 
 
Capacitive loads: according to the load, you can choose 2-5 times power.
 
Inductive loads: according to the load, you can choose 4-7 times power.

  .....................................................................................................................................................................................................................................
 
3.How connection between batteries and an power inverter?
 
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.
 
  .....................................................................................................................................................................................................................................
 
4.How to calculate the load of working hours requires configuration of the battery size?
 
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
 
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
 
.......................................................................................................................................................................................................................................